Comparison of three multiplex immunoassays for detection of antibodies to extractable nuclear antibodies using clinically defined sera

被引:27
作者
Copple, Susan S.
Martins, Thomas B.
Masterson, Charlin
Joly, Erwann
Hill, Harry R.
机构
[1] ARUP Autoimmune Lab, Salt Lake City, UT USA
[2] Biomed Diagnost, Marne La Vallee 2, France
[3] Univ Utah, Sch Med, Salt Lake City, UT USA
来源
AUTOIMMUNITY, PART A: BASIC PRINCIPLES AND NEW DIAGNOSTIC TOOLS | 2007年 / 1109卷
关键词
systemic lupus erythematosus; connective tissue disease; extractable nuclear antibody testing; multiplex microspheres; Luminex;
D O I
10.1196/annals.1398.052
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
We set out to determine the agreement of three multiplex immunoassays for the detection of autoantibodies involved in connective tissue disease using clinically defined sera. Usefulness of the immunoassays will be defined by correlation to disease state. Using the immunoassays from Inova Diagnostics, Biomedical Diagnostics (BMD), and AtheNA, reactivity, to Smith (Sm), ribonucleic protein (RNP), SSA (Ro), SSB (La), Scl-70, and dsDNA or chromatin, we tested 273 clinically defined sera consisting of 57 systemic lupus erythrematosus (SLE) sera, 69 rheumatoid arthritis (RA) sera, 47 sera defined as various other connective tissue diseases, and 100 normal donor sera. Samples were also tested for anti-nuclear antibody (ANA) oN HEp-2 cells by IFA for analysis of discrepant results. Inova, BMD, and AtheNA assays demonstrated 57%, 89%, and 80% concordance, respectively, in the 47 connective tissue disease sera. The BMD assay was the most sensitive in detecting Scl-70. The immunoassays did not correlate well in the 57 SLE-defined sera; however, each had a variety of antibodies positive for each serum. The AtheNA assay demonstrated the highest degree of nonspecificity. Inova, BMD, AtheNA, and the Inova ANA HEp-2 IFA demonstrated 97%, 98%, 97%, and 99% specificity, respectively, using normal sera. Thus, all three assays showed a 97% or better negative predictive value. Positive correlation varied from 83% to 98%. Antibodies in SLE sera did not compare well among the three immunoassays. Significant variation in specificity and sensitivity due to individual characteristics of each assay was demonstrated, with the BMD assay showing the highest correlation with clinical diagnosis.
引用
收藏
页码:464 / 472
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2006, AUTOANTIBODIES AUTOI
[2]   THE AMERICAN-RHEUMATISM-ASSOCIATION 1987 REVISED CRITERIA FOR THE CLASSIFICATION OF RHEUMATOID-ARTHRITIS [J].
ARNETT, FC ;
EDWORTHY, SM ;
BLOCH, DA ;
MCSHANE, DJ ;
FRIES, JF ;
COOPER, NS ;
HEALEY, LA ;
KAPLAN, SR ;
LIANG, MH ;
LUTHRA, HS ;
MEDSGER, TA ;
MITCHELL, DM ;
NEUSTADT, DH ;
PINALS, RS ;
SCHALLER, JG ;
SHARP, JT ;
WILDER, RL ;
HUNDER, GG .
ARTHRITIS AND RHEUMATISM, 1988, 31 (03) :315-324
[3]   From ANA to ENA: How to proceed? [J].
Damoiseaux, JGMC ;
Tervaert, JWC .
AUTOIMMUNITY REVIEWS, 2006, 5 (01) :10-17
[4]   Nucleosome autoantibodies [J].
Decker, P .
CLINICA CHIMICA ACTA, 2006, 366 (1-2) :48-60
[5]   The use of laboratory tests in the diagnosis of SLE [J].
Egner, W .
JOURNAL OF CLINICAL PATHOLOGY, 2000, 53 (06) :424-432
[6]   Clinical significance of antinuclear antibodies - Comparison of detection with immunofluorescence and enzyme-linked immunosorbent assays [J].
Emlen, W ;
ONeill, L .
ARTHRITIS AND RHEUMATISM, 1997, 40 (09) :1612-1618
[7]   Detection of antinuclear antibodies by solid-phase immunoassays and immunofluorescence analysis [J].
Fenger, M ;
Wiik, A ;
Hoier-Madsen, M ;
Lykkegaard, JJ ;
Rozenfeld, T ;
Hansen, MS ;
Samsoe, BD ;
Jacobsen, S .
CLINICAL CHEMISTRY, 2004, 50 (11) :2141-2147
[8]   The Emergence of Multiplexed Technologies as Diagnostic Platforms in Systemic Autoimmune Diseases [J].
Fritzler, Marvin J. ;
Fritzler, Mark L. .
CURRENT MEDICINAL CHEMISTRY, 2006, 13 (21) :2503-2512
[9]   Multiplexed testing in the autoimmunity laboratory [J].
Gonzalez-Buitrago, Jose M. .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (10) :1169-1174
[10]  
GUTIERREZADRIAN.OA, 2006, J RHEUMATOL, V33, P1