RETRACTED: The Diagnostic Performance of 18F-FDG PET/CT in Recurrent Pancreatic Cancer: A Systematic Review and Meta-analysis (Retracted Article)

被引:5
|
作者
Gu, A. [1 ]
Shan, Yuezhan [1 ]
Huo, Huasong [2 ]
Ding, Chao [1 ]
Sun, Caixia [1 ]
机构
[1] Jilin Univ, Dept Gastrointestinal Colorectal & Anal Surg, China Japan Union Hosp, Changchun, Peoples R China
[2] First Hosp Jilin Univ, Dept Neurosurg, Changchun, Peoples R China
关键词
EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; FDG-PET/CT; FOLLOW-UP; LOCAL RECURRENCE; CT; ADENOCARCINOMA; GUIDELINES; MANAGEMENT; RESECTION; UTILITY;
D O I
10.1155/2022/3655225
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose. The CT scan is the best common screening test for pancreatic cancer recurrence after surgery. The goal of our meta-analysis was to assess the diagnostic accuracy of 18F-FDG PET/CT for pancreatic cancer recurrence. Methods. We examined PubMed and Embase for suitable papers between 2009 and 2022. The researchers considered studies that looked at the diagnostic usefulness of 18F-FDG PET/CT in identifying local and/or distant disease recurrence throughout the follow-up following pancreatic cancer resection. The Quality Assessment of Diagnostic Performance Studies-2 (QUADAS-2) method was used to evaluate the quality of each study. For each of the publications included, two researchers extracted data independently. The extracted data included general data (authors, year of publication), literature characteristics (country, type of literature, and design of study), characteristics of the patient (patients' number, mean or median age, and treatment regimen), and technical aspects (scanner, injection activity, and image analysis). Results. The analysis includes 7 trials with a total of 263 patients. The sensitivity and specificity of 18F-FDG PET/CT in detecting recurrent pancreatic cancer following definitive treatment were 0.89 (95 percent CI: 0.83-0.93) and 0.88 (95 percent CI: 0.72-0.96), respectively, according to the pooled estimates. PET/CT performed well in the diagnosis of recurrent pancreatic cancer, with an AUC of 0.94. (0.91-0.95). Conclusions. 18F-FDG PET-CT was found to be a reliable detection method in recurrent pancreatic tumor.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] RETRACTED: Differential Diagnosis of Hemophagocytic Syndrome by 18F-FDG PET/CT: A Meta-Analysis (Retracted Article)
    Zhang, Jun
    He, Bang
    Wang, Jian
    Ying, Caiyun
    Zeng, Lingfeng
    Zheng, Shiyi
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [2] 18F-FDG PET and 18F-FDG PET/CT in Vulvar Cancer A Systematic Review and Meta-analysis
    Triumbari, Elizabeth K. A.
    de Koster, Elizabeth J.
    Rufini, Vittoria
    Fragomeni, Simona M.
    Garganese, Giorgia
    Collarino, Angela
    CLINICAL NUCLEAR MEDICINE, 2021, 46 (02) : 125 - 132
  • [3] The diagnostic performance of 18F-FDG PET/CT in recurrent renal cell carcinoma: a systematic review and meta-analysis
    Fan, Liding
    Xu, Youqiang
    Zhao, Jiahe
    Tang, Weihao
    Zhang, Zhonghang
    Zhang, Yunfei
    Xue, Qingjie
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (02) : 199 - 208
  • [4] The diagnostic performance of 18F-FDG PET/CT in recurrent renal cell carcinoma: a systematic review and meta-analysis
    Liding Fan
    Youqiang Xu
    Jiahe Zhao
    Weihao Tang
    Zhonghang Zhang
    Yunfei Zhang
    Qingjie Xue
    Clinical and Translational Imaging, 2023, 11 : 199 - 208
  • [5] Diagnostic performance of F-18 FDG PET or PET/CT for detection of recurrent gastric cancer: a systematic review and meta-analysis
    Choi, Chang In
    Park, Jae Kyun
    Jeon, Tae Yong
    Kim, Dae-Hwan
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2023, 40 : S37 - S46
  • [6] RETRACTION: The Diagnostic Performance of 18F-FDG PET/CT in Recurrent Pancreatic Cancer: A Systematic Review and Meta-analysis (Retraction of Vol 2022, art no 3655225, 2022)
    Shan, Y.
    Huo, H.
    Ding, C.
    Sun, C.
    APPLIED BIONICS AND BIOMECHANICS, 2023, 2023
  • [7] Diagnostic Performance of 18F-FDG PET and PET/CT for the Detection of Recurrent Esophageal Cancer After Treatment with Curative Intent: A Systematic Review and Meta-Analysis
    Goense, Lucas
    van Rossum, Peter S. N.
    Reitsma, Johannes B.
    Lam, Marnix G. E. H.
    Meijer, Gert J.
    van Vulpen, Marco
    Ruurda, Jelle P.
    van Hillegersberg, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (07) : 995 - 1002
  • [8] Diagnostic Performance of 18F-FDG PET/MR in Evaluating Colorectal Cancer: A Systematic Review and Meta-Analysis
    Mirshahvalad, S.
    Hinzpeter, R.
    Kohan, A.
    Anconina, R.
    Kulanthaivelu, R.
    Ortega, C.
    Metser, U.
    Veit-Haibach, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S480 - S481
  • [9] Diagnostic performance of 18F-FDG PET or PET/CT in restaging renal cell carcinoma: a systematic review and meta-analysis
    Ma, Huan
    Shen, Guohua
    Liu, Bin
    Yang, Yuanyou
    Ren, Pengwei
    Kuang, Anren
    NUCLEAR MEDICINE COMMUNICATIONS, 2017, 38 (02) : 156 - 163
  • [10] 18F-FDG PET and PET/CT as a diagnostic method for Ewing sarcoma: A systematic review and meta-analysis
    Seth, Nimish
    Seth, Ishith
    Bulloch, Gabriella
    Siu, Adrian Hang Yue
    Guo, Allen
    Chatterjee, Rukmini
    MacManus, Michael
    Donnan, Leo
    PEDIATRIC BLOOD & CANCER, 2022, 69 (03)