GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffe, HPLC and enzymatic assays

被引:93
作者
Tsikas, Dimitrios [1 ]
Wolf, Alexander [1 ]
Mitschke, Anja [1 ]
Gutzki, Frank-Mathias [1 ]
Will, Wolfgang [2 ]
Bader, Michael [3 ]
机构
[1] Hannover Med Sch, Inst Clin Pharmacol, D-30625 Hannover, Germany
[2] BASF SE, D-67056 Ludwigshafen, Germany
[3] Hannover Med Sch, Inst Occupat Med, D-30625 Hannover, Germany
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2010年 / 878卷 / 27期
关键词
Creatine; Creatinine; Method comparison; Quality control; Quantification; Validation; CHROMATOGRAPHY-MASS-SPECTROMETRY; CANDIDATE REFERENCE METHOD; SERUM CREATININE; VALIDATION; VALUES;
D O I
10.1016/j.jchromb.2010.04.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In consideration of its relatively constant urinary excretion rate, creatinine in urine is a useful biochemical parameter to correct the urinary excretion rate of endogenous and exogenous biomolecules. Assays based on the reaction of creatinine and picric acid first reported by Jaffe in 1886 still belong to the most frequently used laboratory approaches for creatinine measurement in urine. Further analytical methods for creatinine include HPLC-UV, GC-MS, and LC-MS and LC-MS/MS approaches. In the present article we report on the development, validation and biomedical application of a new GC-MS method for the reliable quantitative determination of creatinine in human urine, plasma and serum. This method is based on thederivatization of creatinine (d(0)-Crea) and the internal standard [methyl-trideutero]creatinine (d(3)-Crea) with pentafluorobenzyl (PFB) bromide in the biological sample directly or after dilution with phosphate buffered saline, extraction of the reaction products with toluene and quantification in 1-mu l aliquots of the toluene extract by selected-ion monitoring of m/z 112 for d(0)-Crea-PFB and m/z 115 for d(3)-Crea-PFB in the electron-capture negative-ion chemical ionization mode. The limit of detection of the method is 100 amol of creatinine. In an inter-laboratory study on urine samples from 100 healthy subjects, the GC-MS method was used to test the reliability of currently used Jaffe, enzymatic and HPLC assays in clinical and occupational studies. The results of the inter-laboratory study indicate that all three tested methods allow for satisfactory quantification of creatinine in human urine. The GC-MS method is suitable for use as a reference method for urinary creatinine in humans. In serum, creatine was found to contribute to creatinine up to 20% when measured by the present GC-MS method. The application of the GC-MS method can be extended to other biological samples such as saliva. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2582 / 2592
页数:11
相关论文
共 31 条
[1]  
*ACGIH, 2008, TLVS BEIS SIGN
[2]  
[Anonymous], 1886, physiol. Chem., DOI DOI 10.1515/BCHM1.1886.10.5.391
[3]   Human experimental exposure study on the uptake and urinary elimination of N-methyl-2-pyrrolidone (NMP) during simulated workplace conditions [J].
Bader, Michael ;
Wrbitzky, Renate ;
Blaszkewicz, Meinolf ;
van Thriel, Christoph .
ARCHIVES OF TOXICOLOGY, 2007, 81 (05) :335-346
[4]   Urinary creatinine concentrations in the US population: Implications for urinary biologic monitoring measurements [J].
Barr, DB ;
Wilder, LC ;
Caudill, SP ;
Gonzalez, AJ ;
Needham, LL ;
Pirkle, JL .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2005, 113 (02) :192-200
[5]  
BERGMAN A, 1980, CLIN CHEM, V26, P1729
[6]  
Beyer Cornelis, 1993, Clinical Chemistry, V39, P1613
[7]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[8]  
Carobene A, 1997, CLIN CHEM, V43, P1342
[9]   The equilibrium between creatine and creatinine, in aqueous solution. The effect of hydrogen ion [J].
Edgar, G ;
Shiver, HE .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1925, 47 :1179-1188
[10]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CREATININE [J].
EKELUND, S ;
PABY, P .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (01) :67-71