Diaphragm design improvement for a metering pump

被引:3
作者
Mimmi, G
Pennacchi, P
机构
[1] Univ Pavia, Dipartimento Meccan Strutturale, I-27100 Pavia, Italy
[2] Politecn Milan, Dipartimento Meccan, I-20133 Milan, Italy
关键词
diaphragm failures; pump failures; cracks; fatigue design;
D O I
10.1016/S1350-6307(00)00007-8
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Since the membrane has to separate the process fluid from the oil circuit in metering diaphragm pumps, it is the critical component of these machines. Sometimes, depending on the operating conditions, the membrane may crack and it is necessary to disassemble the pump and replace this component part. Therefore it is important to improve the design of the membrane to avoid this. In this paper, the behaviour of a membrane mounted in a metering diaphragm pump has been simulated by using FEM. An accurate analysis of the results has allowed the membrane to be redesigned in a more rational way to improve its performance. (C) 2000 Elsevier Science Ltd, All rights reserved.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 3 条
[1]  
[Anonymous], 1995, FINITE ELEMENT METHO
[2]  
FRITSCH H, 1995, KLASSIFIZIERUNG DICH, P93
[3]  
Zienkiewicz O., 2014, FINITE ELEMENT METHO