Can digitally reconstructed radiographs (DRRS) replace simulation films in prostate cancer conformal radiotherapy?

被引:8
作者
Bollet, MA
McNair, HA
Hansen, VN
Norman, A
O'Doherty, U
Taylor, H
Rose, M
Mukherjee, R
Huddart, R
机构
[1] Royal Marsden NHS Trust, Acad Unit Radiotherapy & Oncol, Sutton, Surrey, England
[2] Royal Marsden NHS Trust, Dept Radiotherapy, Sutton, Surrey, England
[3] Royal Marsden NHS Trust, Dept Comp & Informat, Sutton, Surrey, England
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2003年 / 57卷 / 04期
关键词
digitally reconstructed radiographs; treatment verification; precision;
D O I
10.1016/S0360-3016(03)01379-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the precision of using digitally reconstructed radiographs (DRRs) of either 3 mm or 6 mm slice separation vs. using simulator images for the setup verification of patients receiving CT planned conformal radiotherapy to the prostate. To calculate the transfer error between CT and simulator. Methods and Materials: Twenty patients were CT scanned (3 mm slice spacing/width). DRRs were generated for both 3 mm (DRR 3) and 6 mm (DRR 6) separations. DRRs and a simulator image of an anterior and a lateral field were used as reference images. Five observers matched each of the reference images to treatment images using the Theraview "Target check" facility. It was assumed that poorer images would lead to a loss of precision of field placement estimations (FPE) between observers. The study was designed to detect a difference greater than 1.5 mm(2) in the precision of image placement. The transfer error was the mean difference in the setup error derived from the DRRs and the simulation films. Results: The precision of evaluations for simulator films and 3 mm DRRs were similar. There was a trend for the DRR 6 mm to achieve less precise results which was greatest for craniocaudal examinations (variance: simulator 1.5 mm(2), DRR6 2.8 mm(2), p = 0.17), but this did not reach statistical significance. A range of transfer errors was identified, with standard deviations ranging from 1.7 to 4.2 mm. There was evidence of a significant systematic bias in anterior craniocaudal (1.3-1.9 mm, p < 0.004) and anterior posterior (-1.9 mm, p = 0.027). Conclusion: The precision of setup evaluations using DRRs is similar to that achieved by using simulator fields when planning conformal prostate radiotherapy. The use of DRRs could reduce systematic errors introduced in the planning process. (C) 2003 Elsevier Inc.
引用
收藏
页码:1122 / 1130
页数:9
相关论文
共 10 条
[1]   TRANSFER ERRORS OF PLANNING CT TO SIMULATOR - A POSSIBLE SOURCE OF SETUP INACCURACIES [J].
BEL, A ;
BARTELINK, H ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1994, 31 (02) :176-180
[2]   MULTIDIMENSIONAL TREATMENT PLANNING .2. BEAM EYE-VIEW, BACK PROJECTION, AND PROJECTION THROUGH CT SECTIONS [J].
GOITEIN, M ;
ABRAMS, M ;
ROWELL, D ;
POLLARI, H ;
WILES, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (06) :789-797
[3]   Accuracy of pelvic radiotherapy: Prospective analysis of 90 patients in a randomised trial of blocked versus standard radiotherapy [J].
Huddart, RA ;
Nahum, A ;
Neal, A ;
McLean, M ;
Dearnaley, DP ;
Law, M ;
Dyer, J ;
Tait, D .
RADIOTHERAPY AND ONCOLOGY, 1996, 39 (01) :19-29
[4]   Set-up verification using portal imaging; review of current clinical practice [J].
Hurkmans, CW ;
Remeijer, P ;
Lebesque, JV ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 58 (02) :105-120
[5]   An evaluation of three-field coplanar plans for conformal radiotherapy of prostate cancer [J].
Khoo, VS ;
Bedford, JL ;
Webb, S ;
Dearnaley, DP .
RADIOTHERAPY AND ONCOLOGY, 2000, 55 (01) :31-40
[6]   The importance of computed tomography slice thickness in radiographic patient positioning for radiosurgery [J].
Murphy, MJ .
MEDICAL PHYSICS, 1999, 26 (02) :171-175
[7]   COMPUTATION OF DIGITALLY RECONSTRUCTED RADIOGRAPHS FOR USE IN RADIOTHERAPY TREATMENT DESIGN [J].
SHEROUSE, GW ;
NOVINS, K ;
CHANEY, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :651-658
[8]   FAST CALCULATION OF THE EXACT RADIOLOGICAL PATH FOR A 3-DIMENSIONAL CT ARRAY [J].
SIDDON, RL .
MEDICAL PHYSICS, 1985, 12 (02) :252-255
[9]   SOLUTION TO TREATMENT PLANNING PROBLEMS USING COORDINATE TRANSFORMATIONS [J].
SIDDON, RL .
MEDICAL PHYSICS, 1981, 8 (06) :766-774
[10]   A prospective, randomized study addressing the need for physical simulation following virtual simulation [J].
Valicenti, RK ;
Waterman, FM ;
Corn, BW ;
Curran, WJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (05) :1131-1135