A Method for Rapid Self-Calibration of Wearable Soft Strain Sensors

被引:15
作者
Feng, Yaqing [1 ]
Chen, Xiangyu [2 ]
Wu, Qingxun [3 ]
Cao, Guofeng [4 ]
McCoul, David [5 ]
Huang, Bo [1 ]
Zhao, Jianwen [1 ]
机构
[1] Harbin Inst Technol, Dept Mech Engn, Weihai 264209, Peoples R China
[2] Weihai Municipal Hosp, Weihai 264299, Peoples R China
[3] Beijing Inst Mech Equipment, Beijing 100854, Peoples R China
[4] Heilongjiang Coll Business & Technol, Harbin 150025, Peoples R China
[5] Univ Calif Los Angeles, Dept Mat Sci & Engn, Los Angeles, CA 90095 USA
关键词
Sensors; Strain; Wearable sensors; Calibration; Capacitive sensors; Optical sensors; Joints; Motion measurement; redundant sensor; self-calibration; sensor misalignment; soft sensor; wearable sensor;
D O I
10.1109/JSEN.2021.3095875
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Compared to rigid sensors, soft stain sensors are more suitable for measuring human joint motion because soft sensors are more comfortable to wear. In order to perform more precise measurements, the soft stain sensor should be re-calibrated before performing each measurement in order to eliminate error from donning and doffing. Current calibration methods are often performed by optical motion capture systems (OMCSs). However OMCSs are large and cumbersome, and there is no directly applicable calibration method for soft stain sensors in the measurement of human joint motion. Calibration should be able to be performed quickly and without the need of large equipment such as OMCSs. This paper proposes a calibration method for wearable soft strain sensors that can be done quickly and automatically. The soft sensor structure for self-calibration is parallel and partitioned, and there are integrated primary and redundant sensors. The basic idea of this method is to use redundant sensors to re-calibrate the primary sensor, and only a simple calibration action is required for the self-calibration. After self-calibration, the average errors of measurement were all less than 5 degrees, and the relative errors were all less than 4% for sensor and clothing donned and doffed and long-term sensor migration while wearing. Self-calibration can be performed in only 10 seconds. The results presented that the proposed calibration method is feasible for engineering applications.
引用
收藏
页码:20943 / 20950
页数:8
相关论文
共 50 条
  • [21] Self-Calibration of Accelerometer Arrays
    Schopp, Patrick
    Graf, Hagen
    Burgard, Wolfram
    Manoli, Yiannos
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2016, 65 (08) : 1913 - 1925
  • [22] A SEVA soft sensor method based on self-calibration model and uncertainty description algorithm
    Liu Yiqi
    Huang Daoping
    Li Zhifu
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2013, 126 : 38 - 49
  • [23] Self-Calibration of Sensors Using Point Cloud Feature Extraction
    Ravindranath, Pradeep Anand
    Byukburc, Kutluhan
    Hasnain, Ali
    SPIE FUTURE SENSING TECHNOLOGIES (2020), 2020, 11525
  • [24] A linear method for camera pair self-calibration
    Melanitis, Nikos
    Maragos, Petros
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2021, 210
  • [25] A Self-Calibration Method for an Implantable Displacement Sensor
    Hao, Shiying
    2013 IEEE INTERNATIONAL CONFERENCE ON MICROWAVES, COMMUNICATIONS, ANTENNAS AND ELECTRONICS SYSTEMS (IEEE COMCAS 2013), 2013,
  • [26] Measurement data self-calibration fusion method
    Fu H.
    Yang H.
    Wen X.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2019, 34 (08): : 1759 - 1763
  • [27] A Self-Calibration Method for Rotational Stereo Vision
    Guo, Beili
    Guan, Qiu
    Chen, S. Y.
    2009 INTERNATIONAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND COMPUTATIONAL INTELLIGENCE, VOL III, PROCEEDINGS, 2009, : 128 - 132
  • [28] Soft mechanical sensors for wearable and implantable applications
    Papani, Rithvik
    Li, Yang
    Wang, Sihong
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2024, 16 (03)
  • [29] A WEIGHTED ITERATIVE METHOD FOR ROBUST SELF-CALIBRATION
    Liu Shigang Wu Chengke Tang Li Jia Jing (National Key Laboratory of ISN
    Journal of Electronics(China), 2006, (05) : 713 - 717
  • [30] Self-Calibration of Angular Position Sensors by Signal Flow Networks
    Gao, Zhenyi
    Zhou, Bin
    Hou, Bo
    Li, Chao
    Wei, Qi
    Zhang, Rong
    SENSORS, 2018, 18 (08)