Feasibility of peak volume, side pixel and multiple peak registration in high-resolution continuum source atomic absorption spectrometry

被引:119
作者
Heitmann, Uwe [1 ]
Welz, Bernhard [1 ]
Borges, Daniel L. G. [2 ]
Lepri, Fabio G. [2 ]
机构
[1] ISAS Inst Analyt Sci, Dept Interface Spect, D-12489 Berlin, Germany
[2] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
关键词
high-resolution continuum-source atomic absorption spectrometry; pixel detector; wavelength-selected absorbance; peak volume selected absorbance; absorption line width;
D O I
10.1016/j.sab.2007.10.011
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
In high-resolution continuum source atomic absorption spectrometry (HR-CS AAS) with a pixel detector, such as a charge-coupled device array for signal registration, the absorbance A not only depends on the absorption coefficient, the length of the absorbing layer and the number of absorbing atoms therein, but also on the spectral interval over which the signal is recorded, i.e., the spectral bandwidth per pixel and the number of pixels evaluated. Although the problem of different (absorption and emission) line widths is known for several decades already to exist in conventional line source AAS, it is usually disregarded. By choosing a certain number of pixels in HR-CS AAS a defined wavelength interval can be selected over which the absorbance is recorded. As the numerical values obtained this way are not directly comparable with the conventional absorbance, it is necessary to define new terms and symbols for this kind of signal evaluation. With a steady-state signal the individual pixel absorbance values can be added or integrated, resulting in the unit-free wavelength-selected absorbance (WSA, symbol A(Sigma)), or the wavelength-integrated absorbance (WIA, symbol A(lambda)) having a wavelength unit, such as picometers; (pm). Similarly, with transient signals one can add-up or integrate (over wavelength) the individual integrated (in time) absorbance values of the selected pixels to obtain the volume under the absorbance peak. This results in the peak volume selected absorbance (PVSA, symbol A(Sigma),int), and the peak volume integrated absorbance (PVIA, symbol A(lambda),int), with the units second (s) and second times picometer (s pm), respectively. For comparison purposes, however, the integrated absorbance values, i.e., WIA or PVIA, should be used since they are instrument-independent. Several elements with narrow and broad absorption lines and with multiplets, respectively, have been chosen to investigate the feasibility of using different signal registration schemes. Especially the evaluation of WSA and PVSA with respect to sensitivity, linearity of the calibration curves and limits of detection was focused on. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:1222 / 1230
页数:9
相关论文
共 26 条
[1]  
BeckerRoss H, 1996, FRESEN J ANAL CHEM, V355, P300
[2]   WIDTHS OF ATOMIC RESONANCE LINES FROM HOLLOW-CATHODE LAMPS [J].
BRUCE, CF ;
HANNAFORD, P .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1971, B 26 (04) :207-+
[4]   Extended calibration ranges for continuum source atomic absorption spectrometry with array detection [J].
Harnly, JM ;
Smith, CMM ;
Radziuk, B .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1055-1079
[5]  
Harnly JM, 1996, FRESEN J ANAL CHEM, V355, P501
[6]   Measurements on the Zeeman-splitting of analytical lines by means of a continuum source graphite furnace atomic absorption spectrometer with a linear charge coupled device array [J].
Heitmann, U ;
Schutz, M ;
BeckerRoss, H ;
Florek, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (9-10) :1095-1105
[7]  
HEITMANN U, 2002, 7 RIO S ATOMOIC SPEC, P200
[8]   BACKGROUND CORRECTIONS IN LONG PATH ATOMIC ABSORPTION SPECTROMETRY [J].
KOIRTYOHANN, SR ;
PICKETT, EE .
ANALYTICAL CHEMISTRY, 1965, 37 (04) :601-+
[9]   Speciation analysis of volatile and non-volatile vanadium compounds in Brazilian crude oils using high-resolution continuum source graphite furnace atomic absorption spectrometry [J].
Lepri, FG ;
Welz, B ;
Borges, DLG ;
Silva, AF ;
Vale, MGR ;
Heitmann, U .
ANALYTICA CHIMICA ACTA, 2006, 558 (1-2) :195-200
[10]   QUALITY-CONTROL OF HOLLOW-CATHODE LAMPS IN ZEEMAN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
LVOV, BV ;
KOCHAROVA, NV ;
POLZIK, LK ;
ROMANOVA, NP ;
YARMAK, YI .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (06) :843-854