Ultrasensitive electrochemical detection of metal ions using dicarboethoxycalixarene-based sensor

被引:19
作者
Ruslan, N. I. [1 ]
Lim, D. C. K. [2 ]
Ahmad, S. A. Alang [1 ,3 ]
Aziz, S. F. N. Abdul [1 ]
Supian, F. L. [2 ]
Yusof, N. A. [1 ]
机构
[1] Univ Putra Malaysia, Dept Chem, Fac Sci, Upm Serdang 43400, Selangor, Malaysia
[2] Univ Pendidikan Sultan Idris, Fac Sci & Math, Dept Phys, Tanjong Malim 35900, Perak, Malaysia
[3] Univ Putra Malaysia, Inst Adv Technol, Upm Serdang 43400, Selangor, Malaysia
关键词
Calixarene; Heavy metals; Functionalization; Indium tin oxide; Electrochemical sensor; Modified electrode; ULTRA-TRACE LEVELS; STRIPPING VOLTAMMETRY; SELECTIVE DETECTION; HEAVY-METALS; PRECONCENTRATION; COPPER(II); COMPLEXES; ELECTRODE; REMOVAL; FE(III);
D O I
10.1016/j.jelechem.2017.06.038
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we have reported an electrochemical detection of metal ions based on Calixarene-based sensor. In the sensing strategy, 3-aminopropylsilane (APTMS) was initially self-assembled on indium tin oxide (ITO) followed by functionalization of dicarboethoxy-calix [4]arene (EtC4). The morphology and properties of electrodes were characterized by contact angle, atomic force microscopy, cyclic voltammetry, electrochemical impedance spectroscopy and X-ray photoelectron spectroscopy. The electrochemical response characteristics of the modified electrodes (EtC4/APTMS/ITO) towards analyte ions; Zn(II), Cu(II), and Fe(II) ions were investigated by differential pulse voltammetry (DPV) under optimized conditions. It was found that the response of modified electrode towards the analytes was improved significantly as compared to the ITO electrode and resulted in limit of detections (LOD) of 9.88 pg/L, 8.33 mu g/L and 1.15 mu g/L, respectively. In addition, the detection limit of simultaneous detection quantification of Cu2+ Zn2+ and Fe2+ ions could be achieved with the concentration 6.19 ng/L, 3.02 mg/L and 2.79 mg/L, respectively. It is worth to show that dicarboethoxy-calix [4]arene modified electrode is a promising candidate as electrochemical sensors for simultaneous and ultrasensitive heavy metal ions determination.
引用
收藏
页码:497 / 504
页数:8
相关论文
共 41 条
  • [1] A highly sensitive method for simultaneous determination of ultra trace levels of copper and cadmium in food and water samples with luminol as a chelating agent by adsorptive stripping voltammetry
    Abbasi, Shahryar
    Bahiraei, Atousa
    Abbasai, Freshteh
    [J]. FOOD CHEMISTRY, 2011, 129 (03) : 1274 - 1280
  • [2] Determination of ultra trace levels of copper in food samples by a highly sensitive adsorptive stripping voltammetric method
    Abbasi, Shahryar
    Khani, Hossein
    Tabaraki, Reza
    [J]. FOOD CHEMISTRY, 2010, 123 (02) : 507 - 512
  • [3] Molecular recognition: from solution science to nano/materials technology
    Ariga, Katsuhiko
    Ito, Hiroshi
    Hill, Jonathan P.
    Tsukube, Hiroshi
    [J]. CHEMICAL SOCIETY REVIEWS, 2012, 41 (17) : 5800 - 5835
  • [4] Individual and simultaneous determination of lead, cadmium, and zinc by anodic stripping voltammetry at a bismuth bulk electrode
    Armstrong, Kristie C.
    Tatum, Clarissa E.
    Dansby-Sparks, Royce N.
    Chambers, James Q.
    Xue, Zi-Ling
    [J]. TALANTA, 2010, 82 (02) : 675 - 680
  • [5] The silver electrode in square-wave anodic stripping voltammetry. Determination of Pb2+ without removal of oxygen
    Brand, M
    Eshkenazi, I
    KirovaEisner, E
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (22) : 4660 - 4664
  • [6] Mercury nanodroplets supported at biochar for electrochemical determination of zinc ions using a carbon paste electrode
    de Oliveira, Paulo Roberto
    Lamy-Mendes, Alyne Cristina
    Gogola, Jeferson Luiz
    Mangrich, Antonio Salvio
    Marcolino Junior, Luiz Humberto
    Bergamini, Marcio F.
    [J]. ELECTROCHIMICA ACTA, 2015, 151 : 525 - 530
  • [7] Calixarene-Based Fluorescent Sensors for Cesium Cations Containing BODIPY Fluorophore
    Depauw, Alexis
    Kumar, Naresh
    Ha-Thi, Minh-Huong
    Leray, Isabelle
    [J]. JOURNAL OF PHYSICAL CHEMISTRY A, 2015, 119 (23) : 6065 - 6073
  • [8] Simultaneous determination of trace levels of lead(II) and copper(II) by square wave stripping voltammetry using a glassy carbon electrode modified with hierarchical gold dendrites
    Fei, Yao
    Lv, Zhang-Ying
    Wang, Ai-Jun
    Chen, Ye-Hong
    Chen, Jian-Rong
    Feng, Jiu-Ju
    [J]. MICROCHIMICA ACTA, 2014, 181 (3-4) : 389 - 394
  • [9] AIOOH-Reduced Graphene Oxide Nanocomposites: One-Pot Hydrothermal Synthesis and Their Enhanced Electrochemical Activity for Heavy Metal Ions
    Gao, Chao
    Yu, Xin-Yao
    Xu, Ren-Xia
    Liu, Jin-Huai
    Huang, Xing-Jiu
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2012, 4 (09) : 4672 - 4682
  • [10] Calixarene-engineered surfaces and separation science
    Gezici, Orhan
    Bayrakci, Mevlut
    [J]. JOURNAL OF INCLUSION PHENOMENA AND MACROCYCLIC CHEMISTRY, 2015, 83 (1-2) : 1 - 18