Integrated medical feedback systems for drug delivery

被引:80
作者
Heller, A [1 ]
机构
[1] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
关键词
D O I
10.1002/aic.10489
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Drugs are now administered at frequencies and doses based on averages optimized for large populations. Because the optimal frequency and dose for an individual differs, transiently or permanently, from that of a population's average, the dosing is necessarily suboptimal. Feedback loop-based individualized integrated medical systems, comprising an implanted sensor, battery, amplifier, processor, and actuator are non; in use in cardiac pacemakers and defibrillators. Drug-delivering medical,feedback loops, comprising miniature sensors and drug pumps, would individualize, and thereby improve the effectiveness and safety of drugs. Their sensor would continuously or frequently monitor the effect of the drug and adjust, through a medical control algorithm, its flow to the minimum necessary for effectiveness, reducing thereby side effects and improving the success rate of experimental drugs. The pace of integration of the drug delivering feedback loops depends on the availability of proven miniature components and of medical control algorithms. (c) 2005 American Institute of Chemical Engineers
引用
收藏
页码:1054 / 1066
页数:13
相关论文
共 84 条
[1]   Closed-loop control of anesthesia using bispectral index - Performance assessment in patients undergoing major orthopedic surgey under combined general and regional anesthesia [J].
Absalom, AR ;
Sutcliffe, N ;
Kenny, GN .
ANESTHESIOLOGY, 2002, 96 (01) :67-73
[2]   EFFECT OF QUATERNIZATION ON ELECTRON-DIFFUSION COEFFICIENTS FOR REDOX HYDROGELS BASED ON POLY(4-VINYLPYRIDINE) [J].
AOKI, A ;
RAJAGOPALAN, R ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (14) :5102-5110
[3]   ELECTRON-DIFFUSION COEFFICIENTS IN HYDROGELS FORMED OF CROSS-LINKED REDOX POLYMERS [J].
AOKI, A ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (42) :11014-11019
[4]   Electroreduction of O2 to water at 0.6 V (SHE) at pH 7 on the 'wired' Pleurotus ostreatus laccase cathode [J].
Barton, SC ;
Pickard, M ;
Vazquez-Duhalt, R ;
Heller, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1071-1074
[5]   Electroreduction of O2 to water on the "Wired" laccase cathode [J].
Barton, SC ;
Kim, HH ;
Binyamin, G ;
Zhang, YC ;
Heller, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2001, 105 (47) :11917-11921
[6]   The "wired" laccase cathode:: High current density electroreduction of O2 to water at+0.7 V (NHE) at pH 5 [J].
Barton, SC ;
Kim, HH ;
Binyamin, G ;
Zhang, YC ;
Heller, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (24) :5802-5803
[7]   SUGAR ELECTRODE SENSOR FOR ARTIFICIAL PANCREAS [J].
BESSMAN, SP ;
SCHULTZ, RD .
HORMONE AND METABOLIC RESEARCH, 1972, 4 (06) :413-417
[8]   Stabilization of wired glucose oxidase anodes rotating at 1000 rpm at 37°C [J].
Binyamin, G ;
Heller, A .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1999, 146 (08) :2965-2967
[9]   Sources of instability of 'wired' enzyme anodes in serum: urate and transition metal ions [J].
Binyamin, G ;
Chen, T ;
Heller, A .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 500 (1-2) :604-611
[10]   Mechanical and electrochemical characteristics of composites of wired glucose oxidase and hydrophilic graphite [J].
Binyamin, G ;
Cole, J ;
Heller, A .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2000, 147 (07) :2780-2783