Transcatheter valve implantation for degenerated tricuspid bioprosthesis and failed tricuspid ring

被引:7
作者
Chen, Shmuel [1 ]
Dershowitz, Lyle [1 ]
George, Isaac [1 ]
机构
[1] Columbia Univ Irving Med Ctr, NewYork Presbyterian Hosp, Div Cardiac Thorac & Vasc Surg, New York, NY USA
关键词
Transcatheter tricuspid valve replacement; valve in valve; valve in ring; IN-VALVE; REPLACEMENT; OUTCOMES; COMPLICATIONS; SURGERY;
D O I
10.21037/acs-2021-tviv-11
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Transcatheter tricuspid valve-in-valve (TViV) and valve in-ring (TViR) implantation have become a viable therapy for a failed tricuspid bioprosthesis. Here we report short (thirty days) and long (oneyear) term clinical outcomes of ten patients who underwent TViV at our institution. Methods: The electronic databases of New York Presbyterian Columbia Medical Center were retrospectively reviewed for cases of transcatheter tricuspid valve replacement (TViV or TViR). Between 2012 and 2019, data from ten patients who underwent TViV were collected. The primary safety outcome was procedure-related adverse events, including clinically evident cardiac perforation, new pericardial effusion and sustained ventricular arrhythmia. The primary efficacy endpoint was defined as successful valve deployment with total (paravalvular or intravalvular) tricuspid regurgitation (TR) estimated as mild or less. Results are descriptive in nature. Results: A total of ten patients who underwent TViV were included in the study. Of them, 40% presented with isolated tricuspid bioprosthetic stenosis (TS), 20% with isolated TR and 40% with mixed TS and TR. All patients were treated with the SAPIEN valve (first generation, XT, or Sapien 3). The TViV procedure was successful in all patients, and no immediate post-replacement paravalvular leak (PVL) or intra-procedural complications were reported. The primary safety and efficacy endpoints were met in all patients. At thirty days, all patients were alive and reported significant improvements in symptoms and functional status. Conclusions: Transcatheter tricuspid valve implantation is a safe and effective therapy for degenerative tricuspid bioprosthesis.
引用
收藏
页码:651 / +
页数:9
相关论文
共 18 条
[1]  
AVCIN M, 1950, Med Glas, V4, P107
[2]   Reoperations after tricuspid valve repair [J].
Bernal, JM ;
Morales, D ;
Revuelta, C ;
Llorca, J ;
Gutiérrez-Morlote, J ;
Revuelta, JM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (02) :498-503
[3]   Comparison of the Outcome of Porcine Bioprosthetic Versus Mechanical Prosthetic Replacement of the Tricuspid Valve in the Ebstein Anomaly [J].
Brown, Morgan L. ;
Dearani, Joseph A. ;
Danielson, Gordon K. ;
Cetta, Frank ;
Connolly, Heidi M. ;
Warnes, Carole A. ;
Li, Zhuo ;
Hodge, David O. ;
Driscoll, David J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (04) :555-561
[4]   Direct TAVI using a balloon-expandable system: a novel technique to eliminate pre-deployment balloon aortic valvuloplasty [J].
Davies, William R. ;
Bapat, Vinayak N. ;
Hancock, Jane E. ;
Young, Christopher P. ;
Redwood, Simon R. ;
Thomas, Martyn R. .
EUROINTERVENTION, 2014, 10 (02) :248-252
[5]   Long-term outcomes of tricuspid valve replacement in the current era [J].
Filsoufi, F ;
Anyanwu, AC ;
Salzberg, SP ;
Frankel, T ;
Cohn, LH ;
Adams, DH .
ANNALS OF THORACIC SURGERY, 2005, 80 (03) :845-850
[6]   Twenty-Five Year Outcomes of Tricuspid Valve Replacement Comparing Mechanical and Biologic Prostheses [J].
Garatti, Andrea ;
Nano, Giovanni ;
Bruschi, Giuseppe ;
Canziani, Alberto ;
Colombo, Tiziano ;
Frigiola, Alessandro ;
Martinelli, Luigi ;
Menicanti, Lorenzo .
ANNALS OF THORACIC SURGERY, 2012, 93 (04) :1146-1153
[7]   Mechanical Tricuspid Valve Replacement Is Not Superior in Patients Younger Than 65 Years Who Need Long-Term Anticoagulation [J].
Hwang, Ho Young ;
Kim, Kyung-Hwan ;
Kim, Ki-Bong ;
Ahn, Hyuk .
ANNALS OF THORACIC SURGERY, 2012, 93 (04) :1154-1161
[8]   Trends and Outcomes of Tricuspid Valve Surgery in North America: An Analysis of More Than 50,000 Patients From The Society of Thoracic Surgeons Database [J].
Kilic, Arman ;
Saha-Chaudhuri, Paramita ;
Rankin, J. Scott ;
Conte, John V. .
ANNALS OF THORACIC SURGERY, 2013, 96 (05) :1546-1552
[9]   Late results of bioprosthetic tricuspid valve replacement in Ebstein's anomaly [J].
Kiziltan, HT ;
Theodoro, DA ;
Warnes, CA ;
O'Leary, PW ;
Anderson, BJ ;
Danielson, GK .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :1539-1544
[10]  
Krishnaswamy Amar, 2018, Interv Cardiol Clin, V7, P65, DOI 10.1016/j.iccl.2017.08.009