Cavity microelectrode for studying manganese dioxide powder as pH sensor

被引:11
作者
Cachet-Vivier, Christine [1 ]
Tribollet, Bernard [2 ]
Vivier, Vincent [2 ]
机构
[1] Univ Paris Est Creteil, CNRS, Inst Chim & Mat Paris Est, F-94320 Thiais, France
[2] Univ Paris 06, CNRS, UPR 15, Lab Interfaces & Syst Electrochim, F-75252 Paris 05, France
关键词
MnO2; pH microsensor; Cavity microelectrode; SURFACE CHARACTERIZATION; ELECTRODE; MICROSCOPY; VICINITY; CATHODE;
D O I
10.1016/j.talanta.2010.05.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The potential-pH response of an electrolytic manganese dioxide is investigated by means of a cavity microelectrode (CME). The potential-pH curves show a complex evolution that could be explained by the disporportionation of MnOOH species, leading to the formation of Mn2+ ions on the MnO2 surface. Such a behaviour is not suited for pH sensor application. However when the tip of the electrode is coated by a Nafion membrane, the potential-pH evolution shows a unique slope close to -60 mV pH(-1). In addition, the sensor exhibits short time responses to pH variations, a good selectivity, and it can be easily renewed compared to classical sensors. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:555 / 559
页数:5
相关论文
共 35 条
[1]   Fabrication of anodically electrodeposited iridium oxide film pH microelectrodes for microenvironmental studies [J].
Bezbaruah, AN ;
Zhang, TC .
ANALYTICAL CHEMISTRY, 2002, 74 (22) :5726-5733
[2]  
Brenet J.P., 1963, Electrochimica Acta, V8, P207
[3]   Electrochemistry of powder material studied by means of the cavity microelectrode (CME) [J].
Cachet-Vivier, C ;
Vivier, V ;
Cha, CS ;
Nedelec, JY ;
Yu, LT .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :181-189
[4]   Microparticle-based iridium oxide ultramicroelectrodes for pH sensing and imaging [J].
El-Giar, Emad Ei-Deen M. ;
Wipf, David O. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 609 (02) :147-154
[5]   INELASTIC NEUTRON-SCATTERING STUDY OF THE PROTON DYNAMICS IN MANGANESE OXIDES .1. GAMMA-MNO2 AND MANGANITE [J].
FILLAUX, F ;
CACHET, CH ;
OUBOUMOUR, H ;
TOMKINSON, J ;
LEVYCLEMENT, C ;
YU, LT .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1993, 140 (03) :585-591
[6]   Thin-film IrOx pH microelectrode for microfluidic-based microsystems [J].
Ges, IA ;
Ivanov, BL ;
Schaffer, DK ;
Lima, EA ;
Werdich, AA ;
Baudenbacher, FJ .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (02) :248-256
[7]   A method of reducing oxygen induced drift in iridium oxide pH sensors [J].
Hendrikse, J ;
Olthuis, W ;
Bergveld, P .
SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (1-2) :97-103
[8]   pH measurement in the vicinity of a cathode evolving hydrogen gas using an antimony microelectrode [J].
Honda, T ;
Murase, K ;
Hirato, T ;
Awakura, Y .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1998, 28 (06) :617-622
[9]   SCANNING ELECTROCHEMICAL MICROSCOPY .19. ION-SELECTIVE POTENTIOMETRIC MICROSCOPY [J].
HORROCKS, BR ;
MIRKIN, MV ;
PIERCE, DT ;
BARD, AJ ;
NAGY, G ;
TOTH, K .
ANALYTICAL CHEMISTRY, 1993, 65 (09) :1213-1224
[10]   Fiber optic pH/Ca2+ fluorescence microsensor based on spectral processing of sensing signals [J].
Ji, J ;
Rosenzweig, Z .
ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) :93-102