Simultaneous detection of Vitamin B12 and Vitamin C from real samples using miniaturized laser-induced graphene based electrochemiluminescence device with closed bipolar electrode

被引:33
作者
Bhaiyya, Manish [1 ]
Pattnaik, Prasant Kumar [1 ]
Goel, Sanket [1 ]
机构
[1] Birla Inst Technol & Sci BITS Pilani, Dept Elect & Elect Engn, MEMS Microfluid & Nanoelect Lab, Hyderabad Campus, Hyderabad 500078, India
关键词
Laser-induced graphene (LIG); Closed bipolar electrodes (C-BPE); Electrochemiluminescence (ECL); Point of care testing (POCT); Sensor; ELECTROCHEMICAL SENSOR; WIRELESS ELECTROCHEMILUMINESCENCE; LOW-COST; FABRICATION; BIOSENSOR; SYSTEM; NANOPARTICLES; DOPAMINE;
D O I
10.1016/j.sna.2021.112831
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Herein, a two and three-channel laser-induced graphene (LIG) based closed bipolar Electrochemiluminescence (LIG-C-BPE-ECL) system was developed for sensing various analytes. Polyimide sheet was extensively used to fabricate two and three-channel LIG-C-BPE-ECL device as it has the ability to produce graphitized zones in a single step. CO2 infrared laser, with optimized parameters, was effectively used to fabricate closed bipolar (C-BPE) and driving electrodes (DEs). A miniaturized portable 3D printed system was developed to hold the device and place the smartphone to create a standalone ECL sensing platform. The smartphone not only captured the ECL signal but also powered the ECL device through DC to DC buck-boost converter. Two and three-channel LIG-C-BPE-ECL device was fabricated for the sensing of both individual and two analytes at the same time. The performance of the two-channel LIG-C-BPE-ECL device was validated by doing individual sensing of Hydrogen peroxide (H2O2), Vitamin B-12 and Vitamin C for the linear range of 0.5-100 mu M, 0.5-1000 nM and 1-1000 mu M with a limit of detection (LOD) 0.303 mu M, 0.109 nM and 0.96 mu M respectively. Subsequently, three-channel LIG-C-BPE-ECL device was fabricated and simultaneous detection of Vitamin B12 and Vitamin C was accomplished. Finally, real sample analysis has been performed by doing concurrent sensing of vitamin B-12 and vitamin C using three-channel LIG-C-BPE-ECL device with a good recovery rate. Such a miniaturized portable LIG-C-BPE-ECL system has great potential to be used in various applications including point of care testing. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 42 条
  • [1] Electrochemical sensing of vitamin B12 deficiency marker methylmalonic acid using PdAu-PPy tailored carbon fiber paper electrode
    Akshaya, K. B.
    Anitha, Varghese
    Nidhin, M.
    Sudhakar, Y. N.
    Louis, George
    [J]. TALANTA, 2020, 217
  • [2] Portable Electrochemiluminescence Platform With Laser-Induced Graphene-Based U-Shaped Bipolar Electrode for Selective Sensing of Various Analytes
    Bhaiyya, Manish
    Pattnaik, Prasant Kumar
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 2021, 68 (05) : 2447 - 2454
  • [3] Electrochemiluminescence sensing of vitamin B12 using laser-induced graphene based bipolar and single electrodes in a 3D-printed portable system
    Bhaiyya, Manish
    Pattnaik, Prasant Kumar
    Goel, Sanket
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2021, 25 (05)
  • [4] Miniaturized Electrochemiluminescence Platform With Laser-Induced Graphene Electrodes for Multiple Biosensing
    Bhaiyya, Manish
    Rewatkar, Prakash
    Salve, Mary
    Pattnaik, Prasant Kumar
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON NANOBIOSCIENCE, 2021, 20 (01) : 79 - 85
  • [5] Miniaturized Electrochemiluminescence Platform With Laser-Induced Graphene-Based Single Electrode for Interference-Free Sensing of Dopamine, Xanthine, and Glucose
    Bhaiyya, Manish L.
    Pattnaik, Prasant Kumar
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [6] Paper-based bipolar electrode-electrochemiluminescence (BPE-ECL) device with battery energy supply and smartphone read-out: A handheld ECL system for biochemical analysis at the point-of-care level
    Chen, Lu
    Zhang, Chunsun
    Xing, Da
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2016, 237 : 308 - 317
  • [7] An electrochemiluminescent biosensor for vitamin C based on inhibition of luminol electrochemiluminescence on graphite/poly(methyl methacrylate) composite electrode
    Dai, Hong
    Wu, Xiaoping
    Wang, Youmei
    Zhou, Weichao
    Chen, Guonan
    [J]. ELECTROCHIMICA ACTA, 2008, 53 (16) : 5113 - 5117
  • [8] Fluorescent carbon dots nanosensor for label-free determination of vitamin B12 based on inner filter effect
    Ding, Longhua
    Yang, Hongmei
    Ge, Shenguang
    Yu, Jinghua
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2018, 193 : 305 - 309
  • [9] Fully Integrated, Automated, and Smartphone Enabled Point-of-Source Portable Platform With Microfluidic Device for Nitrite Detection
    Dudala, Sohan
    Dubey, Satish Kumar
    Goel, Sanket
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2019, 13 (06) : 1518 - 1524
  • [10] Recent advances in electrochemiluminescence devices for point-of-care testing
    Gao, Wenyue
    Saqib, Muhammad
    Qi, Liming
    Zhang, Wei
    Xu, Guobao