Increasing diagnostic accuracy for thyroid nodules by an integrated multivariate approach: a methodological study

被引:0
|
作者
Consorti, F. [1 ]
Cozza, V. [1 ]
Loponte, M. [1 ]
Mardente, S. [2 ]
Milazzo, F. [1 ]
Scardella, L. [1 ]
Antonaci, A. [1 ]
机构
[1] Univ Roma La Sapienza, Dept Surg, Rome, Italy
[2] Univ Roma La Sapienza, Dept Expt Med, I-00185 Rome, Italy
来源
CLINICA TERAPEUTICA | 2011年 / 162卷 / 01期
关键词
multivariate model; ROC curves; thyroid cancer; thyroid cytology; thyroid ultrasound; FINE-NEEDLE-ASPIRATION; ULTRASONOGRAPHIC CHARACTERISTICS; MULTINODULAR GOITER; MALIGNANCY; MANAGEMENT; CARCINOMA; CONTROVERSIES; GUIDELINES;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. Current guidelines for diagnostic management of thyroid nodules are based on a linear approach, using categorial classifications to cluster diagnostic findings and they still lead to unnecessary surgery. A diagnostic scoring system, based on clinical, cytological and ultrasound findings is described. Materials and Methods. Two groups of patients (168 and 55 pts) were used to compute a multivariate model and the discriminating threshold by ROC curves. The performance of the derived scoring system was assessed by a simulation on a third group of 60 patients, who had undergone surgery according to current guidelines. Results. The scoring system displayed a sensitivity of 100%, specificity 53.3%, positive and negative predictive values of 68.1% and 100%. According to the scoring system, 16 out of 60 operations would have been saved. Conclusions. A scoring system can take into account in a more accurate way the full informative content of the fine-grained description of diagnostic and clinical features. Clin Ter 2011; 162(1):31-35
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [21] An integrated AI model to improve diagnostic accuracy of ultrasound and output known risk features in suspicious thyroid nodules
    Juan Wang
    Jue Jiang
    Dong Zhang
    Yao-zhong Zhang
    Long Guo
    Yusheng Jiang
    Shaoyi Du
    Qi Zhou
    European Radiology, 2022, 32 : 2120 - 2129
  • [22] Diagnostic Accuracy of Ultrasonography in Differentiating Benign and Malignant Thyroid Nodules Using Fine Needle Aspiration Cytology as the Reference Standard
    Alam, Tariq
    Khattak, Yasir Jamil
    Beg, Madiha
    Raouf, Abdul
    Azeemuddin, Muhammad
    Khan, Asif Alam
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2014, 15 (22) : 10039 - 10043
  • [23] Development and validation of an ultrasound-based nomogram to improve the diagnostic accuracy for malignant thyroid nodules
    Guo, Bao-liang
    Ouyang, Fu-sheng
    Ouyang, Li-zhu
    Liu, Zi-wei
    Lin, Shao-jia
    Meng, Wei
    Huang, Xi-yi
    Chen, Hai-xiong
    Yang, Shao-ming
    Hu, Qiu-gen
    EUROPEAN RADIOLOGY, 2019, 29 (03) : 1518 - 1526
  • [24] Diagnostic accuracy of ultrasonographic features for benign and malignant thyroid nodules smaller than 10 mm
    Maimaiti, Yusufu
    Sun, Shiran
    Liu, Zeming
    Zeng, Wen
    Liu, Chunping
    Wang, Shuntao
    Xiong, Yiquan
    Guo, Yawen
    Li, Xiaoyu
    Wang, Yu
    He, Wenshan
    Huang, Tao
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (03): : 6476 - 6482
  • [25] Diagnostic Accuracy and Interobserver Agreement of Quasistatic Ultrasound Elastography in the Diagnosis of Thyroid Nodules
    Cantisani, V.
    Lodise, P.
    Di Rocco, G.
    Grazhdani, H.
    Giannotti, D.
    Patrizi, G.
    Medvedyeva, E.
    Olive, M.
    Fioravanti, C.
    Giacomelli, L.
    Chiesa, C.
    Redler, A.
    Catalano, C.
    D'Ambrosio, F.
    Ricci, P.
    ULTRASCHALL IN DER MEDIZIN, 2015, 36 (02): : 162 - 167
  • [26] Diagnostic Accuracy of Contrast-Enhanced Ultrasound Enhancement Patterns for Thyroid Nodules
    Zhang, Yan
    Luo, Yu-kun
    Zhang, Ming-bo
    Li, Jie
    Li, Junlai
    Tang, Jie
    MEDICAL SCIENCE MONITOR, 2016, 22 : 4755 - 4764
  • [27] Diagnostic Efficacy and Safety of Core Needle Biopsy as a First-Line Diagnostic Method for Thyroid Nodules: A Prospective Cohort Study
    Hong, Min Ji
    Na, Dong Gyu
    Lee, Hunkyung
    THYROID, 2020, 30 (08) : 1141 - 1149
  • [28] Ultrasonography and Fine-Needle Aspiration in Indeterminate Thyroid Nodules: A Systematic Review of Diagnostic Test Accuracy
    Staibano, Phillip
    Forner, David
    Noel, Christopher W.
    Zhang, Han
    Gupta, Michael
    Monteiro, Eric
    Sawka, Anna M.
    Pasternak, Jesse D.
    Goldstein, David P.
    de Almeida, John R.
    LARYNGOSCOPE, 2022, 132 (01) : 242 - 251
  • [29] A 10-Gene Classifier for Indeterminate Thyroid Nodules: Development and Multicenter Accuracy Study
    Gonzalez, Hernan E.
    Martinez, Jose R.
    Vargas-Salas, Sergio
    Solar, Antonieta
    Veliz, Loreto
    Cruz, Francisco
    Arias, Tatiana
    Loyola, Soledad
    Horvath, Eleonora
    Tala, Hernan
    Traipe, Eufrosina
    Meneses, Manuel
    Marin, Luis
    Wohllk, Nelson
    Diaz, Rene E.
    Veliz, Jesus
    Pineda, Pedro
    Arroyo, Patricia
    Mena, Natalia
    Bracamonte, Milagros
    Miranda, Giovanna
    Bruce, Elsa
    Urra, Soledad
    THYROID, 2017, 27 (08) : 1058 - 1067
  • [30] The impact of presence of Hashimoto's thyroiditis on diagnostic accuracy of ultrasound-guided fine-needle aspiration biopsy in subcentimeter thyroid nodules: A retrospective study from FUSCC
    Gao, Lili
    Ma, Ben
    Zhou, Li
    Wang, Yu
    Yang, Shuwen
    Qu, Ning
    Gao, Yi
    Ji, Qinghai
    CANCER MEDICINE, 2017, 6 (05): : 1014 - 1022