Peristaltic micropump system with piezoelectric actuators

被引:31
作者
Jang, Ling-Sheng
Yu, Yung-Chiang
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Ctr Micro Nano Sci & Technol, Tainan 701, Taiwan
来源
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS | 2008年 / 14卷 / 02期
关键词
D O I
10.1007/s00542-007-0428-8
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This work presents a driving system for a peristaltic micropump that is based on piezoelectric actuation. The effects of the actuation sequence on pump performance are also considered. A valveless peristaltic micropump based on piezoelectric actuation is designed and fabricated using microelectromechanical system technology. The pump has three parts -- silicon, Pyrex glass and commercially available bulk PZT (lead zirconate titanate) chips. The peristaltic micropump actuated by PZT chips comprises three chambers that are in series. The driving system consists of an ATmega 8535 microprocessor, a high voltage power supply, three differential amplifiers, a phase controller, an A/D converter, a 555 oscillator and an LCD module. It is supplied via a 110 Vrms 60-Hz AC line and is programmable. The system can produce step-function signals with voltages of up to 100 V-pp and frequencies ranging from 10 Hz to 1 kHz, as the inputs for the pump. Fluid pumping with air is successfully demonstrated. Additionally, 3-, 4- and 6-phase actuation sequences for the pump are designed and used to study the effects on pump performance, as revealed by the flow rate and the displacement of a pump diaphragm. The experimental results show that the flow rate and the displacement of the diaphragm actuated by the 4-phase sequence exceed those actuated by the 3- and 6-phase sequences. A flow rate of 17.6 mu l min(-1) and a displacement of 2.91 mu m (peak-to-peak) in 4-phase peristaltic motion are achieved at 100 Hz and 100 V-pp. The results demonstrate that the pump actuated in the 4-phase sequence is the most efficient. Consequently, the actuation sequences can affect the pump performance.
引用
收藏
页码:241 / 248
页数:8
相关论文
共 16 条
[1]  
AHN CH, 1995, MICRO ELECTRO MECHANICAL SYSTEMS - IEEE PROCEEDINGS, 1995, P408, DOI 10.1109/MEMSYS.1995.472590
[2]   A valve-less diffuser micropump for microfluidic analytical systems [J].
Andersson, H ;
van der Wijngaart, W ;
Nilsson, P ;
Enoksson, P ;
Stemme, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (03) :259-265
[3]   Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology [J].
Cao, L ;
Mantell, S ;
Polla, D .
SENSORS AND ACTUATORS A-PHYSICAL, 2001, 94 (1-2) :117-125
[4]  
Carr JJ., 2001, Introduction to Biomedical Equipment Technology
[5]   Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena [J].
Francais, O ;
Dufour, I .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 70 (1-2) :56-60
[6]  
GOPALAN KG, 1996, INTRO DIGITAL MICROE
[7]  
GREIHERR G, 1997, MED DEVICE DIAGNOSTI, V19, P50
[8]   Investigation for the operation of an integrated peristaltic micropump [J].
Husband, B ;
Bu, M ;
Evans, AGR ;
Melvin, T .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2004, 14 (09) :S64-S69
[9]   A stand-alone peristaltic micropump based on piezoelectric actuation [J].
Jang, Ling-Sheng ;
Li, Yuan-Jie ;
Lin, Sung-Ju ;
Hsu, Yi-Chu ;
Yao, Wu-Sung ;
Tsai, Mi-Ching ;
Hou, Ching-Cheng .
BIOMEDICAL MICRODEVICES, 2007, 9 (02) :185-194
[10]   Bidirectional pumping properties of a peristaltic piezoelectric micropump with simple design and chemical resistance [J].
Lee, DS ;
Ko, JS ;
Kim, YT .
THIN SOLID FILMS, 2004, 468 (1-2) :285-290