Limited Utility of a Rapid Quantitative Enzyme-Linked Fluorescent Assay for the D-Dimer in the Diagnosis of Overt Disseminated Intravascular Coagulation

被引:0
作者
Sharma, Prashant [1 ]
Saxena, Renu [1 ]
机构
[1] All India Inst Med Sci, Dept Haematol, New Delhi 110029, India
关键词
bleeding; diagnostic tests; disseminated intravascular coagulation; ISTH scoring algorithm; point-of-care testing; quantitative D-dimer assay; INTERNATIONAL SOCIETY; SCORING SYSTEM; THROMBOSIS; VALIDATION; ISTH;
D O I
10.1177/1076029609360530
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The role of quantitative D-dimer assay in screening for and diagnosing overt disseminated intravascular coagulation (DIC), conventionally diagnosed by the International Society of Thrombosis and Haemostasis' (ISTH) score, was evaluated. Of patients with clinical conditions associated with overt DIC, 142 with ISTH scores >= 5 (compatible with overt DIC) and 61 with ISTH scores <5 (suggestive of nonovert DIC) underwent the quantitative D-dimer assay. Accuracy indices, receiver operating characteristic (ROC) curve-derived cutoffs, and areas under curve were compared. Mean D-dimer level in overt DIC was 4147.2 +/- 2707 ng/mL. In nonovert DIC, it was 1678.9 +/- 1888.3 ng/mL. Both were higher than healthy controls (229.6 +/- 129.9 ng/mL). An optimized cutoff (2040 ng/mL) had relatively low sensitivity (75.4%) and specificity (73.8%). Extensive overlap between groups at this cutoff reduced diagnostic utility. Lowered cutoffs increased sensitivity (eg, 91.5% at 1000 ng/mL) but diminished specificity (59%), limiting use of screening. In conclusion, the quantitative D-dimer as a stand-alone assay has a limited role in diagnosis of overt DIC.
引用
收藏
页码:609 / 613
页数:5
相关论文
共 7 条
[1]   Prospective validation of the International Society of Thrombosis and Haemostasis scoring system for disseminated intravascular coagulation [J].
Bakhtiari, K ;
Meijers, JCM ;
de Jonge, E ;
Levi, M .
CRITICAL CARE MEDICINE, 2004, 32 (12) :2416-2421
[2]   Use of soluble fibrin antigen instead of D-dimer as fibrin-related marker may enhance the prognostic power of the ISTH overt DIC score [J].
Dempfle, CE ;
Wurst, M ;
Smolinski, M ;
Lorenz, S ;
Osika, A ;
Olenik, D ;
Fiedler, F ;
Borggrefe, M .
THROMBOSIS AND HAEMOSTASIS, 2004, 91 (04) :812-818
[3]   Analytic validation and clinical evaluation of the STA LIATEST immunoturbidimetric D-dimer assay for the diagnosis of disseminated intravascular coagulation [J].
Lehman, CM ;
Wilson, LW ;
Rodgers, GM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 122 (02) :178-184
[4]  
Levi M, 2009, BRIT J HAEMATOL, V145, P24, DOI [10.1111/j.1365-2141.2008.07445.x, 10.1111/j.1365-2141.2009.07600.x]
[5]  
Perrier Arnaud, 2006, Evid Based Med, V11, P119, DOI 10.1136/ebm.11.4.119
[6]  
Saxena R, 2003, Indian J Pathol Microbiol, V46, P425
[7]   Towards definition, clinical and laboratory criteria, and a scoring system for disseminated intravascular coagulation - On behalf of the Scientific Subcommittee on Disseminated Intravascular Coagulation (DIC) of the International Society on Thrombosis and Haemostasis (ISTH) [J].
Taylor, FB ;
Toh, CH ;
Hoots, WK ;
Wada, H ;
Levi, M .
THROMBOSIS AND HAEMOSTASIS, 2001, 86 (05) :1327-1330