Microdrop analysis of a bead-based immunoassay

被引:22
作者
Thomas, JH [1 ]
Ronkainen-Matsuno, NJ [1 ]
Farrell, S [1 ]
Halsall, HB [1 ]
Heineman, WR [1 ]
机构
[1] Univ Cincinnati, Dept Chem, Cincinnati, OH 45221 USA
关键词
microbead-based immunoassay; electrochemical immunoassay; rotating disk electrodes; microelectrode; interdigitated array electrode;
D O I
10.1016/S0026-265X(03)00036-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The progress to electrochemical detection of a microbead-based immunoassay in small volumes has led to a reduced assay time and lower detection limits. Three electrochemical techniques are described for an immunoassay with detection in a microdrop. The techniques are amperometric detection with a rotating disk electrode (RDE), a microelectrode. and an interdigitated array (IDA) electrode. An enzyme-labeled sandwich immunoassay with mouse IgG as the model analyte is used to demonstrate the three techniques. The microbead assay is carried out in a test tube using a magnet to control bead collection. Once the immunocomplex is formed on the microbead, the beads are transferred to a microdrop where the enzyme, either alkaline phosphatase or beta-galactosidase, generates 4-aminophenol (PAP). PAP is oxidized at the electrode with an applied potential of + 290 mV vs. Ag/AgCl. For all three techniques, the upper limit of the dynamic range was 1000 ng/ml mouse IgG, and the detection limits were: 50 ng/ml for the RDE. 40 ng/ml for the microelectrode, and 26 ng/ml for the IDA electrode. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:267 / 276
页数:10
相关论文
共 36 条
[1]   CHARACTERIZATION OF GLUCOSE MICROSENSORS FOR INTRACELLULAR MEASUREMENTS [J].
ABE, T ;
LAU, YY ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1992, 64 (18) :2160-2163
[2]   Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system [J].
Aguilar, ZP ;
Vandaveer, WR ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3321-3329
[3]   QUANTITATIVE-ANALYSIS OF REVERSIBLE DIFFUSION-CONTROLLED CURRENTS OF REDOX SOLUBLE SPECIES AT INTERDIGITATED ARRAY ELECTRODES UNDER STEADY-STATE CONDITIONS [J].
AOKI, K ;
MORITA, M ;
NIWA, O ;
TABEI, H .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 256 (02) :269-282
[4]  
Clark RA, 1998, ELECTROANAL CHEM, V20, P227
[5]  
Ekins RP, 1998, CLIN CHEM, V44, P2015
[6]  
FRUMKIN A, 1945, J PHYS CHEM USSR, V19, P573
[7]   STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY [J].
HEINEMAN, WR ;
HALSALL, HB .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :1321-&
[8]  
HEINEMAN WR, 2001, ANAL SCI, V17, P1281
[9]   Biological terrorism - The looming threat of bioterrorism [J].
Henderson, DA .
SCIENCE, 1999, 283 (5406) :1279-1282
[10]   Oxidation state speciation of [ReI(DMPE)3]+/[ReII(DMPE)3]2+ by voltammetry with a chemically modified microelectrode [J].
Hu, ZM ;
Heineman, WR .