Three-Dimensional Reconstruction of Columna Vertebralis Images of Elite Male Weightlifters Taken by a Multi-Detector Computerized Tomography (MDCT)

被引:0
作者
Ince, Alparslan [1 ]
Eken, Emrullah [2 ]
机构
[1] Ordu Univ, Phys Educ & Sport Sch, Kesi Cumhuriyet Mahallesi Merkez, Ordu, Turkey
[2] Selcuk Univ, Dept Anat, Fac Vet Med, Konya, Turkey
来源
INTERNATIONAL JOURNAL OF MORPHOLOGY | 2014年 / 32卷 / 04期
关键词
Columna vertebralis; Three-dimensional reconstruction; Elite weightlifters; Computerized tomography; KINEMATIC ANALYSIS; SNATCH TECHNIQUE; FORCES; CT;
D O I
10.4067/S0717-95022014000400010
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
This study aims to carry out a comparative study on the vertebral structure of the elite male weightlifters and the sedentary group (control group) by obtaining three-dimensional data and models by means of photogrammetry from the columna vertebralis sections taken by MDCT. The columna vertebralis of the 8 male weightlifters and 8 sedentary individuals (control group) was scanned with a high-definition diagnostic MDCT device during the study. The demographic findings suggest no difference in both the weightlifters and the sedentary individual. The 2D axial images in DICOM format were burnt on CDs and then copied on a PC on which 3D-Doctor 4.0, which is a 3D modelling program had already been installed. The reconstruction was carried out with the 3D rendering component of the program. All the data were automatically measured by the abovementioned program and the statistical analyses were determined with a -t test by SPSS 15. Considering the statistical results of the Columna vertebralis, only in the length of Pars lumbaris some statistically considerable differences (p<0.05) were observed between the vertebras L3-L5 in the elite male weightlifters and the sedentary individuals. Therefore, concluding from the idea that these techniques and the three-dimensional reconstruction procedures should be put into practice in the field of sports medicine, the substructure works that will be carried out on weightlifters by means of MDCT are thought to be supported by these studies.
引用
收藏
页码:1184 / 1189
页数:6
相关论文
共 18 条
[1]   IMPACT OF SEMIAUTOMATED VERSUS MANUAL IMAGE SEGMENTATION ERRORS ON MYOCARDIAL STRAIN CALCULATION BY MAGNETIC-RESONANCE TAGGING [J].
BAZILLE, A ;
GUTTMAN, MA ;
MCVEIGH, ER ;
ZERHOUNI, EA .
INVESTIGATIVE RADIOLOGY, 1994, 29 (04) :427-433
[2]   The effects of exercise on human articular cartilage [J].
Eckstein, F ;
Hudelmaier, M ;
Putz, R .
JOURNAL OF ANATOMY, 2006, 208 (04) :491-512
[3]  
Gourgoulis V, 2002, J STRENGTH COND RES, V16, P359
[4]  
Hall R K, 1994, Aust Orthod J, V13, P86
[5]  
Harbili E., 2005, HACETTEPE J SPORT SC, V16, P124
[6]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[7]   Kinematic analysis of the barbell during the snatch movement of elite Asian weight lifters [J].
Isaka, T ;
Okada, J ;
Funato, K .
JOURNAL OF APPLIED BIOMECHANICS, 1996, 12 (04) :508-516
[8]  
Kalayci I, 2008, J SPORT SCI MED, V7, P544
[9]   Strategies for CT radiation dose optimization [J].
Kalra, MK ;
Maher, MM ;
Toth, TL ;
Hamberg, LM ;
Blake, MA ;
Shephard, JA ;
Saini, S .
RADIOLOGY, 2004, 230 (03) :619-628
[10]  
Krupa P., 2004, NEURORADIOLOGY, P141