Long-term vessel response to a self-expanding coronary stent: A serial volumetric intravascular ultrasound analysis from the ASSURE trial

被引:66
作者
Kobayashi, Y
Honda, Y
Christie, LG
Teirstein, PS
Bailey, SR
Brown, CL
Matthews, RV
De Franco, AC
Schwartz, RS
Goldberg, S
Popma, JJ
Yock, PG
Fitzgerald, PJ
机构
[1] Stanford Univ, Med Ctr, Ctr Res Cardiovasc Intervent, Stanford, CA 94305 USA
[2] Cardiovasc Associates, Eugene, OR USA
[3] Scripps Clin, La Jolla, CA USA
[4] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
[5] Piedmont Hosp, Atlanta, GA USA
[6] Los Angeles Cardiol Associates, Los Angeles, CA USA
[7] Moses Cone Mem Hosp, Greensboro, NC USA
[8] Mayo Clin, Rochester, MN USA
[9] Cooper Hosp, Boston, MA USA
[10] Massachusetts Gen Hosp, Boston, MA 02114 USA
基金
美国医疗保健研究与质量局; 美国国家卫生研究院;
关键词
D O I
10.1016/S0735-1097(01)01162-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the influence of the chronic stimulus from self-expanding stents on the vessel wall remains unknown. METHODS Sixty-two patients were randomly assigned to either the RADIUS self-expanding stent group (n = 32) or the Palmaz-Schatz balloon-expandable stent group (n = 30). Intravascular ultrasound was performed after stent deployment and at six-month follow-up. RESULTS At follow-up, the RADIUS stents had increased 23.6% in overall volume, while the Palmaz-Schatz stents had remained unchanged. Due to the greater mean neointimal area (3.0 +/- 1.7 mm(2) vs. 1.9 +/- 1.2 mm(2), p = 0.02) in the RADIUS group, no significant difference in net late lumen loss was observed between the two groups. On the other hand, analysis at the peristent margins demonstrated that mean late loss was significantly smaller in the RADIUS group than it was in the Palmaz-Schatz group (0.1 +/- 2.1 mm(2) vs. 1.9 +/- 2.4 mm2, p = 0.02). CONCLUSIONS Serial volumetric IVUS revealed that the RADIUS stents continued to enlarge during the follow-up period. In this stent implantation protocol, this expansion was accompanied by a greater amount of neointima than the Palmaz-Schatz stents, resulting in similar late lumen loss in both configurations. In the peristent margins, however, late lumen loss was minimized with the RADIUS stents. (J Am Cell Cardiol 2001;37:1329-34) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1329 / 1334
页数:6
相关论文
共 28 条
  • [11] Three-year follow-up after implantation of metallic coronary-artery stents
    Kimura, T
    Yokoi, H
    Nakagawa, Y
    Tamura, T
    Kaburagi, S
    Sawada, Y
    Sato, Y
    Yokoi, H
    Hamasaki, N
    Nosaka, H
    Nobuyoshi, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) : 561 - 566
  • [12] RESTENOSIS AFTER EXPERIMENTAL ANGIOPLASTY - INTIMAL, MEDIAL, AND ADVENTITIAL CHANGES ASSOCIATED WITH CONSTRICTIVE REMODELING
    LAFONT, A
    GUZMAN, LA
    WHITLOW, PL
    GOORMASTIC, M
    CORNHILL, JF
    CHISOLM, GM
    [J]. CIRCULATION RESEARCH, 1995, 76 (06) : 996 - 1002
  • [13] ASSESSMENT OF NORMAL AND ATHEROSCLEROTIC ARTERIAL-WALL THICKNESS WITH AN INTRAVASCULAR ULTRASOUND IMAGING CATHETER
    MALLERY, JA
    TOBIS, JM
    GRIFFITH, J
    GESSERT, J
    MCRAE, M
    MOUSSABECK, O
    BESSEN, M
    MORIUCHI, M
    HENRY, WL
    [J]. AMERICAN HEART JOURNAL, 1990, 119 (06) : 1392 - 1400
  • [14] THE CONTRIBUTION OB TISSUE REMOVAL TO LUMEN IMPROVEMENT AFTER DIRECTIONAL CORONARY ATHERECTOMY
    MATAR, FA
    MINTZ, GS
    FARB, A
    DOUEK, P
    PICHARD, AD
    KENT, KM
    SATLER, LF
    POPMA, JJ
    KELLER, MB
    PINNOW, E
    MERRITT, AJ
    LINDSAY, J
    LEON, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 74 (07) : 647 - 650
  • [15] Angiographic patterns of in-stent restenosis - Classification and implications for long-term outcome
    Mehran, R
    Dangas, G
    Abizaid, AS
    Mintz, GS
    Lansky, AJ
    Satler, LF
    Pichard, AD
    Kent, KM
    Stone, GW
    Leon, MB
    [J]. CIRCULATION, 1999, 100 (18) : 1872 - 1878
  • [16] Intravascular ultrasound predictors of restenosis after percutaneous transcatheter coronary revascularization
    Mintz, GS
    Popma, JJ
    Pichard, AD
    Kent, KM
    Satler, LF
    Chuang, YC
    Griffin, J
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (07) : 1678 - 1687
  • [17] Arterial remodeling after coronary angioplasty - A serial intravascular ultrasound study
    Mintz, GS
    Popma, JJ
    Pichard, AD
    Kent, KM
    Satler, LF
    Wong, SC
    Hong, MK
    Kovach, JA
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (01) : 35 - 43
  • [18] Mudra H, 1997, CIRCULATION, V95, P363
  • [19] INTRAVASCULAR ULTRASOUND IMAGING - INVITRO VALIDATION AND PATHOLOGICAL CORRELATION
    NISHIMURA, RA
    EDWARDS, WD
    WARNES, CA
    REEDER, GS
    HOLMES, DR
    TAJIK, AJ
    YOCK, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (01) : 145 - 154
  • [20] APPLICATION OF A NEW PHASED-ARRAY ULTRASOUND IMAGING CATHETER IN THE ASSESSMENT OF VASCULAR DIMENSIONS - INVIVO COMPARISON TO CINEANGIOGRAPHY
    NISSEN, SE
    GRINES, CL
    GURLEY, JC
    SUBLETT, K
    HAYNIE, D
    DIAZ, C
    BOOTH, DC
    DEMARIA, AN