Long-term vessel response to a self-expanding coronary stent: A serial volumetric intravascular ultrasound analysis from the ASSURE trial

被引:66
作者
Kobayashi, Y
Honda, Y
Christie, LG
Teirstein, PS
Bailey, SR
Brown, CL
Matthews, RV
De Franco, AC
Schwartz, RS
Goldberg, S
Popma, JJ
Yock, PG
Fitzgerald, PJ
机构
[1] Stanford Univ, Med Ctr, Ctr Res Cardiovasc Intervent, Stanford, CA 94305 USA
[2] Cardiovasc Associates, Eugene, OR USA
[3] Scripps Clin, La Jolla, CA USA
[4] Univ Texas, Hlth Sci Ctr, San Antonio, TX USA
[5] Piedmont Hosp, Atlanta, GA USA
[6] Los Angeles Cardiol Associates, Los Angeles, CA USA
[7] Moses Cone Mem Hosp, Greensboro, NC USA
[8] Mayo Clin, Rochester, MN USA
[9] Cooper Hosp, Boston, MA USA
[10] Massachusetts Gen Hosp, Boston, MA 02114 USA
基金
美国医疗保健研究与质量局; 美国国家卫生研究院;
关键词
D O I
10.1016/S0735-1097(01)01162-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the influence of the chronic stimulus from self-expanding stents on the vessel wall remains unknown. METHODS Sixty-two patients were randomly assigned to either the RADIUS self-expanding stent group (n = 32) or the Palmaz-Schatz balloon-expandable stent group (n = 30). Intravascular ultrasound was performed after stent deployment and at six-month follow-up. RESULTS At follow-up, the RADIUS stents had increased 23.6% in overall volume, while the Palmaz-Schatz stents had remained unchanged. Due to the greater mean neointimal area (3.0 +/- 1.7 mm(2) vs. 1.9 +/- 1.2 mm(2), p = 0.02) in the RADIUS group, no significant difference in net late lumen loss was observed between the two groups. On the other hand, analysis at the peristent margins demonstrated that mean late loss was significantly smaller in the RADIUS group than it was in the Palmaz-Schatz group (0.1 +/- 2.1 mm(2) vs. 1.9 +/- 2.4 mm2, p = 0.02). CONCLUSIONS Serial volumetric IVUS revealed that the RADIUS stents continued to enlarge during the follow-up period. In this stent implantation protocol, this expansion was accompanied by a greater amount of neointima than the Palmaz-Schatz stents, resulting in similar late lumen loss in both configurations. In the peristent margins, however, late lumen loss was minimized with the RADIUS stents. (J Am Cell Cardiol 2001;37:1329-34) (C) 2001 by the American College of Cardiology.
引用
收藏
页码:1329 / 1334
页数:6
相关论文
共 28 条
  • [1] SELF-EXPANDABLE NITINOL STENT FOR CARDIOVASCULAR APPLICATIONS - CANINE AND HUMAN-EXPERIENCE
    BEYAR, R
    SHOFTI, R
    GRENEDIER, E
    HENRY, M
    GLOBERMAN, O
    BEYAR, M
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 32 (02): : 162 - 170
  • [2] Coronary stenting with a novel stainless steel balloon-expandable stent: Determinants of neointimal formation and changes in arterial geometry after placement in an atherosclerotic model
    Carter, AJ
    Laird, JR
    Kufs, WM
    Bailey, L
    Hoopes, TG
    Reeves, T
    Farb, A
    Virmani, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 27 (05) : 1270 - 1277
  • [3] Relationship between plaque mass and neointimal hyperplasia after stent placement in Yucatan micropigs
    deSmet, BJGL
    Kuntz, RE
    vanderHelm, YJ
    Pasterkamp, G
    Borst, C
    Post, MJ
    [J]. RADIOLOGY, 1997, 203 (02) : 484 - 488
  • [4] SELF-EXPANDABLE AND HIGHLY FLEXIBLE NITINOL STENT - IMMEDIATE AND LONG-TERM RESULTS IN DOGS
    GRENADIER, E
    SHOFTI, R
    BEYAR, M
    LICHTIG, H
    MORDECHOWITZ, D
    GLOBERMAN, O
    MARKIEWICZ, W
    BEYER, R
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (05) : 870 - 878
  • [5] Serial intravascular ultrasound predictors of restenosis at the margins of Palmaz-Schatz stents
    Hoffmann, R
    Mintz, GS
    Kent, KM
    Satler, LF
    Pichard, AD
    Popma, JJ
    Leon, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) : 951 - &
  • [6] Patterns and mechanisms of in-stent restenosis - A serial intravascular ultrasound study
    Hoffmann, R
    Mintz, GS
    Dussaillant, GR
    Popma, JJ
    Pichard, AD
    Satler, LF
    Kent, KM
    Griffin, J
    Leon, MB
    [J]. CIRCULATION, 1996, 94 (06) : 1247 - 1254
  • [7] Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents
    Hoffmann, R
    Mintz, GS
    Mehran, R
    Pichard, AD
    Kent, KM
    Satler, LF
    Popma, JJ
    Wu, HS
    Leon, MB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) : 43 - 49
  • [8] Acute and chronic effects of self-expanding nitinol stents in porcine coronary arteries
    Hong, MK
    Beyar, R
    Kornowski, R
    Tio, FO
    Bramwell, O
    Leon, MB
    [J]. CORONARY ARTERY DISEASE, 1997, 8 (01) : 45 - 48
  • [9] SMOOTH-MUSCLE CELL-PROLIFERATION IS PROPORTIONAL TO THE DEGREE OF BALLOON INJURY IN A RAT MODEL OF ANGIOPLASTY
    INDOLFI, C
    ESPOSITO, G
    DILORENZO, E
    RAPACCIUOLO, A
    FELICIELLO, A
    PORCELLINI, A
    AVVEDIMENTO, VE
    CONDORELLI, M
    CHIARIELLO, M
    [J]. CIRCULATION, 1995, 92 (05) : 1230 - 1235
  • [10] CORONARY INTIMAL PROLIFERATION AFTER BALLOON INJURY AND STENTING IN SWINE - AN ANIMAL-MODEL OF RESTENOSIS
    KARAS, SP
    GRAVANIS, MB
    SANTOIAN, EC
    ROBINSON, KA
    ANDERBERG, KA
    KING, SB
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 467 - 474