Large-volume atmosphere-controlled high-temperature x-ray diffraction furnace

被引:41
作者
Misture, ST [1 ]
机构
[1] Alfred Univ, New York State Coll Ceram, Alfred, NY 14802 USA
关键词
high-temperature diffraction; diffraction; furnace; x-ray;
D O I
10.1088/0957-0233/14/7/326
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A new fully automated powder diffraction furnace that operates from 20 to 1600degreesC under controlled atmosphere or vacuum is reported. The diffraction furnace provides a large heated volume and stable sample positioning, thus minimizing systematic errors in the powder diffraction patterns and temperature control. The thermal expansion of alumina over the temperature range of 20-1420degreesC was used to evaluate the temperature and sample positioning errors. Analysis of 16 datasets collected over the course of 7 months, including some full-pattern Pawley refinements and Rietveld analysis, demonstrates that the thermal expansion of Al2O3 can be determined with good accuracy up to at least 1420degreesC. The specimen displacement was determined as a function of temperature using full-pattern fitting and remains well under 100 mum across the 20-1420degreesC temperature range. Heating rates of up to 1200degreesC min(-1) can be achieved without overshoot. Cooling, rates of 600degreesC min(-1) are possible at temperatures above 1300degreesC, while cooling rates of approximately 60degreesC min(-1) are possible down to similar to700degreesC. Atmosphere control is possible, and oxygen partial pressures of less than 10(-5) atm can be obtained routinely under a blanket gas.
引用
收藏
页码:1091 / 1098
页数:8
相关论文
共 25 条
[11]  
JENKINS R, 1989, REV MINERAL, V20, P47
[12]  
Jenkins R., 1989, Powder Diffr, V4, P74, DOI DOI 10.1017/S0885715600016456
[13]  
Klug H.P., 1974, XRAY DIFFRACTION PRO, V2nd, P992
[14]  
Misture S. T., 1994, POWDER DIFFR, V9, P172, DOI DOI 10.1017/S0885715600019175
[15]  
Misture S. T., 2002, ADV XRAY ANAL, V45, P25
[16]   UNIT-CELL REFINEMENT FROM POWDER DIFFRACTION SCANS [J].
PAWLEY, GS .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1981, 14 (DEC) :357-361
[17]  
PETERSON MS, 2002, IN PRESS ADV XRAY AN
[18]   High-temperature double-crystal X-ray diffractometer for in situ studies, the hotbird [J].
Sequeira, AD ;
Franco, N ;
Neves, J .
EPDIC 7: EUROPEAN POWDER DIFFRACTION, PTS 1 AND 2, 2001, 378-3 :206-211
[19]   HOT STAGE FOR X-RAY DIFFRACTION OF CERAMIC SYSTEMS [J].
SEWARD, TP ;
MOLEA, FN ;
UHLMANN, DR .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1965, 36 (12) :1851-&
[20]  
SEYMOUR DI, 2001, CERAMIC ENG SCI P, V22, P161