FAULT RIDE-THROUGH CAPABILITY OF WIND TURBINE CONNECTED TO THE GRID IN THE CASE OF UNBALANCED VOLTAGES

被引:0
|
作者
Ivanovic, Zoran R. [1 ]
Vekic, Marko S. [1 ]
Grabic, Stevan U. [1 ]
Todorovic, Ivan M. [1 ]
机构
[1] Univ Novi Sad, Fac Tech Sci, Novi Sad, Serbia
来源
THERMAL SCIENCE | 2016年 / 20卷
关键词
wind turbine; distributed generator; fault ride-through capability; back-to-back converter; hardware-in-the-loop; CONTROL SCHEME; PWM CONVERTER; POWER-CONTROL;
D O I
10.2298/TSCI150929033I
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with control of wind turbine connected to the grid through the back-to-back converter in case of unbalanced grid voltages. The motivation for this research has been found in recent transmission and distribution grid code, which demand modern wind turbines to stay connected to the grid and supply the highest possible apparent power during the grid disturbances. In order to comply with these requirements we proposed improved dual vector current controller to deal with the unbalance imposed by the electrical grid. Controller provides injection of active and reactive power to the grid, even if the voltages are lower than the nominal one. The results are validated using low power prototype and contemporary hardware-in-the-loop emulation platform. In both cases the controller is based on TMS320F2812 DSP.
引用
收藏
页码:S495 / S512
页数:18
相关论文
共 50 条
  • [21] Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
    Al-Shetwi, Ali Q.
    Sujod, Muhamad Zahim
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (02):
  • [22] Fault ride-through capability test unit for wind turbines
    Ausin, Juan Carlos
    Gevers, Daniel Navarro
    Andresen, Bjorn
    WIND ENERGY, 2008, 11 (01) : 3 - 12
  • [23] Study of Fault Ride-Through Capability of Doubly Fed Induction Generator Based Wind Turbine
    Ntuli, Khulekani
    Sharma, Gulshan
    Kabeya, Musasa
    30TH SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE (SAUPEC 2022), 2022,
  • [24] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Ran, Li
    Xiang, Dawei
    Tavner, Peter J.
    Yang, Shunchang
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 1623 - 1623
  • [25] Low Voltage Ride-through Control for Fixed Speed Wind Generators under Grid Unbalanced Fault
    Ren, Jiajia
    Hu, Yinghong
    Ji, Yanchao
    Liu, Chuang
    2012 TWENTY-SEVENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2012, : 686 - 689
  • [26] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Xiang, Dawei
    Ran, Li
    Tavner, Peter J.
    Yang, Shunchang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) : 652 - 662
  • [27] Fault Ride-Through Capability Improvement of Grid Connected PV System Using Dynamic Voltage Restorer
    AbuHussein, Ahmed
    Sadi, Mohammad Ashraf Hossain
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2020, 48 (12-13) : 1296 - 1307
  • [28] A control strategy for enhancing the Fault Ride-Through capability of a microgrid during balanced and unbalanced grid voltage sags
    Gkavanoudis, Spyros I.
    Demoulias, Charis S.
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2015, 3 : 1 - 11
  • [29] A Novel Wind Turbine Concept Based on an Electromagnetic Coupler and the Study of Its Fault Ride-through Capability
    You, Rui
    Barahona, Braulio
    Chai, Jianyun
    Cutululis, Nicolaos A.
    ENERGIES, 2013, 6 (11): : 6120 - 6136
  • [30] Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC
    Mosayyebi, Seyed Reza
    Shahalami, Seyed Hamid
    Mojallali, Hamed
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)