Identifying gait asymmetry using gyroscopes-A cross-correlation and Normalized Symmetry Index approach

被引:55
作者
Gouwanda, Darwin [1 ]
Senanayake, S. M. N. Arosha [1 ]
机构
[1] Monash Univ, Selangor Darul Ehsan 46150, Malaysia
关键词
Wireless gyroscope; Gait symmetry; Symmetry Index; Cross-correlation; GROUND REACTION FORCE; ABLE-BODIED GAIT; WALKING; STROKE; PARAMETERS; VARIABLES; ANGLE;
D O I
10.1016/j.jbiomech.2010.12.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Injury to a lower limb may disrupt natural walking and cause asymmetrical gait, therefore assessing the gait asymmetry has become one of the important procedures in gait analysis. This paper proposes the use of wireless gyroscopes as a new instrument to determine gait asymmetry. It also introduces two novel approaches: normalized cross-correlations (Cc(norm)) and Normalized Symmetry Index (SInorm). Cc(norm) evaluates the waveform patterns generated by the lower limb in each gait cycle. SInorm provides indications on the timing and magnitude of the bilateral differences between the limbs while addressing the drawbacks of the conventional methods. One-way ANOVA test reveals that Cc(norm) can be considered as single value indicator that determines the gait asymmetry (p < 0.01). The experiment results showed that SInorm in asymmetrical gait were different from normal gait. SInorm in asymmetrical gait were found to be approximately 20% greater than SInorm in normal gait during pre-swing and initial swing. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:972 / 978
页数:7
相关论文
共 32 条
  • [1] Simultaneous bilateral 3-D able-bodied gait
    Allard, P
    Lachance, R
    Aissaoui, R
    Duhaime, M
    [J]. HUMAN MOVEMENT SCIENCE, 1996, 15 (03) : 327 - 346
  • [2] PROSTHETIC ALIGNMENT EFFECTS ON GAIT SYMMETRY - A CASE-STUDY
    ANDRES, RO
    STIMMEL, SK
    [J]. CLINICAL BIOMECHANICS, 1990, 5 (02) : 88 - 96
  • [3] BALASUBRAMANIAN, 2007, REHABILITATION, V88, P43
  • [4] BECKER HP, 1995, CLIN ORTHOP RELAT R, P262
  • [5] BRANDSTATER ME, 1983, ARCH PHYS MED REHAB, V64, P583
  • [6] A method for analyzing joint symmetry and normalcy, with an application to analyzing gait
    Crenshaw, Stephanie J.
    Richards, James G.
    [J]. GAIT & POSTURE, 2006, 24 (04) : 515 - 521
  • [7] The influence of walking speed on parameters of gait symmetry determined from ground reaction forces
    Crowe, A
    Samson, MM
    Hoitsma, MJ
    vanGinkel, AA
    [J]. HUMAN MOVEMENT SCIENCE, 1996, 15 (03) : 347 - 367
  • [8] TEMPORAL ASYMMETRY AS A GAIT QUALITY INDICATOR
    DEWAR, ME
    JUDGE, G
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (05) : 689 - 693
  • [9] Ambulatory measurement of 3D knee joint angle
    Favre, J.
    Jolles, B. M.
    Aissaoui, R.
    Aminian, K.
    [J]. JOURNAL OF BIOMECHANICS, 2008, 41 (05) : 1029 - 1035
  • [10] Application of Hybrid Multi-Resolution Wavelet Decomposition Method in Detecting Human Walking Gait Events
    Gouwanda, Darwin
    Senanayake, S. M. N. Arosha
    [J]. 2009 INTERNATIONAL CONFERENCE OF SOFT COMPUTING AND PATTERN RECOGNITION, 2009, : 580 - 585