Diamond microstrip detector for deep UV imaging

被引:5
作者
Ciancaglioni, I
Spaziani, F
Rossi, MC
Conte, G
Kononenko, V
Ralchenko, V
机构
[1] Univ Rome Roma Tre, INFM, I-00146 Rome, Italy
[2] Univ Rome Roma Tre, Dept Elect Engn, I-00146 Rome, Italy
[3] Russian Acad Sci, Ctr Nat Sci, Inst Gen Phys, Moscow 119991, Russia
关键词
deep UV imaging; detectors; photoconductivity; CVD diamond;
D O I
10.1016/j.diamond.2005.01.037
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
CVD diamond detectors with metal diamond metal (MDM) microstrip structures have been constructed and characterized for image sensor and large area applications. These sensors are suitable for UV and soft X-ray detection. The device photoelectrical characterization under deep UV (lambda=193 nm) laser pulses has been performed both on the nucleation and growth sides of a diamond slab, by varying bias voltage, contacts interspacing and light intensity. Such a characterization was also performed on a laser-smoothed part of the growth side. Reflecting the true electronic quality, largely different photocurrent peak shapes were detected on the untreated and laser-treated parts of the growth side, as well as on the nucleation side. Pulse amplitude and duration appear to decrease according to the different defect density value, which turns out to be larger on the laser-treated growth side of the diamond slab. Independent of pulsed illumination intensity, a linear photoresponse increase with the applied electric field is found in the range 10(1)-10(4) V/cm. Depending on the defect density value, the photocurrent versus pulse energy changes according to a different power law, the linear dependence extending into a wider pulse energy range when larger defect densities are involved. Such a characteristics is also a figure of the wide signal dynamics. The sensor uniformity has been also tested both on as grown and laser-treated surface, as well as on the nucleation side surface where a linear signal increase has been found by adding adjacent strips connected in parallel. These results suggest the suitability of the sensor for image acquisition. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:526 / 530
页数:5
相关论文
共 15 条
  • [1] CVD diamond dosimetric response evaluated by X-ray absorbers method
    Ascarelli, P
    Cappelli, E
    Trucchi, DM
    Conte, G
    [J]. DIAMOND AND RELATED MATERIALS, 2003, 12 (3-7) : 691 - 695
  • [2] CONTE G, UNPUB J APPL PHYS
  • [3] CVD diamond photoconductors for picosecond radiation pulse characterisation
    Foulon, F
    Bergonzo, P
    Jany, C
    Gicquel, A
    Pochet, T
    [J]. DIAMOND AND RELATED MATERIALS, 1996, 5 (6-8) : 732 - 736
  • [4] Imaging deep UV light with diamond-based systems
    Lansley, SP
    Gaudin, O
    Ye, HT
    Rizvi, N
    Whitfield, MD
    McKeag, RD
    Jackman, RB
    [J]. DIAMOND AND RELATED MATERIALS, 2002, 11 (3-6) : 433 - 436
  • [5] Deep UV pulsed laser monitoring by CVD diamond sensors
    Mazzeo, G
    Salvatori, S
    Rossi, MC
    Conte, G
    Castex, MC
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2004, 113 (03) : 277 - 281
  • [6] POLYCRYSTALLINE DIAMOND PHOTOCONDUCTIVE DEVICE WITH HIGH UV-VISIBLE DISCRIMINATION
    MCKEAG, RD
    CHAN, SSM
    JACKMAN, RB
    [J]. APPLIED PHYSICS LETTERS, 1995, 67 (15) : 2117 - 2119
  • [7] PACE E, 2003, OR PRES DIAM C SALZB
  • [8] CARRIER DENSITY DEPENDENT PHOTOCONDUCTIVITY IN DIAMOND
    PAN, LS
    KANIA, DR
    PIANETTA, P
    LANDEN, OL
    [J]. APPLIED PHYSICS LETTERS, 1990, 57 (06) : 623 - 625
  • [9] Ralchenko VG, 1997, DIAMOND FILM TECHNOL, V7, P15
  • [10] Large-area diamond deposition by microwave plasma
    Ralchenko, VG
    Smolin, AA
    Konov, VI
    Sergeichev, KF
    Sychov, IA
    Vlasov, II
    Migulin, VV
    Voronina, SV
    Khomich, AV
    [J]. DIAMOND AND RELATED MATERIALS, 1997, 6 (2-4) : 417 - 421