Determination of estrogens in human serum using a novel chemical derivatization-assisted liquid chromatography-electrospray ionization-tandem mass spectrometry method

被引:2
|
作者
Kang, Chong-Xin [1 ]
Fan, Ru-Ting [1 ]
Xiao, Hua-Ming [1 ,2 ]
Wang, Xian [1 ]
机构
[1] South Cent Minzu Univ, Sch Chem & Mat Sci, Key Lab Analyt Chem State Ethn Affairs Commiss, Wuhan 430074, Peoples R China
[2] Chinese Acad Agr Sci, Oil Crops Res Inst, Key Lab Oilseeds Proc, Hubei Key Lab Lipid Chem & Nutr,Minist Agr, Wuhan, Peoples R China
基金
中国国家自然科学基金;
关键词
IMMUNOSORBENT-ASSAY ELISA; POSTMENOPAUSAL WOMEN; HUMAN PLASMA; ESTRADIOL; CHLORIDE; FRAGMENTATION; METABOLITES; EFFICIENCY; HORMONES;
D O I
10.1002/rcm.9345
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale Assessing estrogen concentrations in biological systems can provide valuable information on physiological processes, which is crucial for the early diagnosis of many diseases. Because estrogens are present in the human body in low concentrations and in a wide dynamic range, analytical methods with high sensitivity and specificity are required for their determination in complex biological matrices. Methods To discover an appropriate derivatization reagent for estrogen mass spectrometry (MS) analysis, we compared five sulfonyl chloride derivatization reagents, namely 3-methyl-8-quinolinesulfonyl chloride (MQSCl) and 8-quinolinesulfonyl chloride (QSCl), 1-methyl-1H-pyrazole-4-sulfonyl chloride, 1,2-methyl-imidazole-5-sulfonyl chloride, and dansyl chloride. By selecting the derivatization reagent with the best performance, we developed and validated a novel chemical derivatization-assisted-liquid chromatography-electrospray ionization-tandem mass spectrometry (CD-LC-ESI-MS/MS) method to simultaneously determine the concentrations of estrone, estradiol, and estriol (E1, E2, and E3) in human serum. Results It was found that among the five investigated reagents, MQSCl-derivatized estrogens presented the highest sensitivity using LC-ESI-MS/MS. Based on this discovery, MQSCl was chosen to derivatize the analyzed estrogens to assist LC-ESI-MS/MS analysis. The limit of quantification of E1, E2, and E3 was measured as 2.7, 4.6, and 5.1 pg/mL, respectively. Inter- and intra-day precision, expressed as the coefficient of variation, was shown to be lower than 13.2% for all concentrations. The mean recovery was 72.4% overall, with good reproducibility at low, medium, and high concentrations in the calibration range. Conclusions The developed method was successfully applied to the quantitative determination of estrogens in clinical human serum from pediatric and adult women, demonstrating the suitability of estrogen analysis in the biological matrix at low concentration (pg/mL).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] CREATININE DETERMINATION IN URINE BY LIQUID CHROMATOGRAPHY-ELECTROSPRAY IONIZATION-TANDEM MASS SPECTROMETRY METHOD
    Derezinski, Pawel
    Klupczynska, Agnieszka
    Sawicki, Wojciech
    Kokot, Zenon J.
    ACTA POLONIAE PHARMACEUTICA, 2016, 73 (02): : 303 - 313
  • [2] Determination of cymipristone in human plasma by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Jiang, Bo
    Ruan, Zourong
    Lou, Honggang
    Yuan, Hong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (7-8): : 719 - 723
  • [3] Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry
    Hayama, T
    Yoshida, H
    Onimaru, S
    Yonekura, S
    Kuroki, H
    Todoroki, K
    Nohta, H
    Yamaguchi, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01): : 131 - 136
  • [4] A Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry Method for Quantitation of Aripiprazole in Human Plasma
    Lin, Shen-Nan
    Lamm, Lolita
    Newton, Thomas F.
    Reid, Malcolm S.
    Moody, David E.
    Foltz, Rodger L.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (05) : 237 - 242
  • [5] Simultaneous determination of antiretroviral drugs in human hair with liquid chromatography-electrospray ionization-tandem mass spectrometry
    Wu, Yan
    Yang, Jin
    Duan, Cailing
    Chu, Liuxi
    Chen, Shenghuo
    Qiao, Shan
    Li, Xiaoming
    Deng, Huihua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1083 : 209 - 221
  • [6] Sensitive Determination of Quinones by High-Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry with Methanol Derivatization
    Jiying Pei
    Yinghui Wang
    Kefu Yu
    Analytical Sciences, 2018, 34 : 335 - 339
  • [7] Sensitive Determination of Quinones by High-Performance Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry with Methanol Derivatization
    Pei, Jiying
    Wang, Yinghui
    Yu, Kefu
    ANALYTICAL SCIENCES, 2018, 34 (03) : 335 - 340
  • [8] Determination of nalmefene by high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
    Fang, WB
    Andrenyak, DM
    Moody, DE
    Nuwayser, ES
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2005, 29 (03) : 169 - 174
  • [9] Determination of Total Choline by Liquid Chromatography-Electrospray Ionization-Tandem Mass Spectrometry in Infant Formulas
    Fu, Shishan
    Tao, Baohua
    Lai, Shiyun
    Zhang, Jingshun
    Ren Yiping
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (01) : 157 - 162
  • [10] Rapid and accurate determination of dichlorvos in water by liquid chromatography-electrospray ionization-tandem mass spectrometry
    Yang, Lan
    Liu, Yan Hong
    An, Li Zhe
    Li, You-bin
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (20) : 2943 - 2955