Ultrasound-guided central venous cannulation in a very small preterm neonate

被引:22
作者
Machotta, A
Kerner, S
Höhne, C
Kerner, T
机构
[1] Charite Univ Med Berlin, Klin Anasthesiol & Operat Intensivmed, D-13353 Berlin, Germany
[2] Charite Univ Med Berlin, Klin & Poliklin Kinderchirurg, D-13353 Berlin, Germany
关键词
central venous catheter; internal jugular vein; ultrasound guidance; preterm neonate;
D O I
10.1111/j.1460-9592.2005.01432.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Percutaneous central venous cannulation of small infants is a challenging procedure. The use of ultrasound guidance has been shown to increase the success rate generally in children and to decrease the incidence of associated complications. To demonstrate that this technique is also suitable in very small infants we describe the case of a preterm neonate of 850 g body weight (BW), in which percutaneous central venous cannulation was performed successfully using ultrasound imaging for guidance.
引用
收藏
页码:325 / 327
页数:3
相关论文
共 8 条
[1]   USE OF ULTRASOUND TO EVALUATE INTERNAL JUGULAR-VEIN ANATOMY AND TO FACILITATE CENTRAL VENOUS CANNULATION IN PEDIATRIC-PATIENTS [J].
ALDERSON, PJ ;
BURROWS, FA ;
STEMP, LI ;
HOLTBY, HM .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (02) :145-148
[2]   Ultrasound-guided central venous cannulation in infants and children [J].
Åsheim, P ;
Mostad, U ;
Aadahl, P .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (04) :390-392
[3]   Ultrasonic locating devices for central venous cannulation: meta-analysis [J].
Hind, D ;
Calvert, N ;
McWilliams, R ;
Davidson, A ;
Paisley, S ;
Beverley, C ;
Thomas, S .
BMJ-BRITISH MEDICAL JOURNAL, 2003, 327 (7411) :361-364
[4]   Complications and risks of central venous catheter placement in children [J].
Johnson, EM ;
Saltzman, DA ;
Suh, G ;
Dahms, RA ;
Leonard, AS .
SURGERY, 1998, 124 (05) :911-916
[5]   Ultrasound-assisted cannulation of the right internal jugular vein during electrophysiologic studies in children [J].
Liberman, L ;
Hordof, AJ ;
Hsu, DT ;
Pass, RH .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2001, 5 (02) :177-179
[6]  
Trautner H, 2003, ANAESTHESIST, V52, P115, DOI 10.1007/s00101-003-0452-8
[7]   Comparison of three techniques for internal jugular vein cannulation in infants [J].
Verghese, ST ;
McGill, WA ;
Patel, RI ;
Sell, JE ;
Midgley, FM ;
Ruttimann, UE .
PAEDIATRIC ANAESTHESIA, 2000, 10 (05) :505-511
[8]   Ultrasound-guided internal jugular venous cannulation in infants - A prospective comparison with the traditional palpation method [J].
Verghese, ST ;
McGill, WA ;
Patel, RI ;
Sell, JE ;
Midgley, FM ;
Ruttimann, UE .
ANESTHESIOLOGY, 1999, 91 (01) :71-77