Fabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation

被引:27
作者
Cox, BT [1 ]
Zhang, EZ [1 ]
Laufer, JG [1 ]
Beard, PC [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6JA, England
来源
AMUM 2004: ADVANCED METROLOGY FOR ULTRASOUND IN MEDICINE 2004 | 2004年 / 1卷
关键词
D O I
10.1088/1742-6596/1/1/009
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
An optical ultrasound sensing method based upon the detection of acoustically-induced changes in the optical thickness of a Fabry Perot (FP) polymer film sensing interferometer has been developed as an alternative to piezoelectric based detection methods for ultrasound measurement applications. The technique provides an inherently broadband (similar to 30MHz) response and excellent detection sensitivities (< 10kPa), comparable to those of piezoelectric PVDF transducers. An important distinguishing feature however is that the sensing geometry is defined by the area of the polymer sensing film that is optically addressed. As a result, very small element sizes can be obtained to provide low directional sensitivity without compromising detection sensitivity - a key advantage over piezoelectric transducers. It also means that, by spatially sampling over a relatively large aperture, a high density ultrasound array can readily be configured. Other advantages are that, the sensing element can be inexpensively batch fabricated using polymer film deposition techniques, has the ability to self-calibrate, is electrically passive and immune to EMI. A range of measurement devices using this type of sensor have now been developed. These include a miniature (0.25mm o.d.) optical fibre hydrophone for in situ measurements of diagnostic and therapeutic medical ultrasound exposure. By rapidly scanning a focused laser beam over a planar FP sensor, a notional array of 3cm aperture, 50 mu m element size and 200 mu m interelement spacing has also been demonstrated for rapid transducer field mapping applications. It is considered that this ability to fabricate acoustically small, highly sensitive receivers in a variety of configurations offers the prospect of developing a valuable new set of ultrasound measurement tools.
引用
收藏
页码:32 / 37
页数:6
相关论文
共 11 条
[1]   Interrogation of free-space Fabry-Perot sensing interferometers by angle tuning [J].
Beard, PC .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) :1998-2005
[2]  
Beard PC, 2000, ULTRASON, P1183, DOI 10.1109/ULTSYM.2000.921534
[3]   Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones [J].
Beard, PC ;
Hurrell, AM ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :256-264
[4]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[5]   Two-dimensional recording of optoacoustic waves [J].
Paltauf, G ;
Schmidt-Kloiber, H ;
Koestli, KP ;
Frenz, M .
LASER-TISSUE INTERACTION X: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, PROCEEDINGS OF, 1999, 3601 :248-255
[6]   FIBEROPTIC PROBE HYDROPHONE FOR ULTRASONIC AND SHOCK-WAVE MEASUREMENTS IN WATER [J].
STAUDENRAUS, J ;
EISENMENGER, W .
ULTRASONICS, 1993, 31 (04) :267-273
[7]   Pressure sensitivity of a fiber-optic microprobe for high-frequency ultrasonic field [J].
Uno, Y ;
Nakamura, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (5B) :3120-3123
[8]   Characterization of an optical multilayer hydrophone with constant frequency response in the range from 1 to 75 MHz [J].
Wilkens, V .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (03) :1431-1438
[9]   Optical multilayer detection array for fast ultrasonic field mapping [J].
Wilkens, V ;
Koch, C .
OPTICS LETTERS, 1999, 24 (15) :1026-1028
[10]   Fiber-optic multilayer hydrophone for ultrasonic measurement [J].
Wilkens, V ;
Koch, C .
ULTRASONICS, 1999, 37 (01) :45-49