Influence of the water spray flow rate and angle on the critical velocity in tunnels with longitudinal ventilation

被引:15
|
作者
Wang, Jie [1 ,3 ,4 ]
Wei, Yinqiu [1 ,3 ,4 ]
Xie, Zhicheng [1 ,3 ,4 ]
Jiang, Xuepeng [1 ,3 ,4 ]
Zhang, Hongjie [1 ,3 ,4 ]
Lu, Kaihua [2 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Resource & Environm Engn, 947 Heping Ave, Wuhan 430081, Hubei, Peoples R China
[2] China Univ Geosci Wuhan, Fac Engn, Wuhan 430074, Hubei, Peoples R China
[3] Hubei Res Ctr Ind Safety Engn Technol, Wuhan 430081, Hubei, Peoples R China
[4] Wuhan Univ Sci & Technol, Fire Safety Technol Inst, Wuhan 430081, Hubei, Peoples R China
基金
中国国家自然科学基金;
关键词
Tunnel fire; Water spray; Critical velocity; Longitudinal ventilation; FIRE-INDUCED SMOKE; CFD; DISPLACEMENT; SUPPRESSION; SYSTEMS; LONG;
D O I
10.1016/j.energy.2019.116466
中图分类号
O414.1 [热力学];
学科分类号
摘要
Recently, the water spray system has been used in important tunnels to weaken the heat release rate of fires and cool the fire smoke, which has a significant impact on the critical velocity that is the minimum longitudinal ventilation required to prevent the fire smoke from spreading upstream of a tunnel. Therefore, a series of tunnel fires with eight heat release rates responding to from a car fire to a bus fire set as 5 MW, 10 MW, 15 MW, 20 MW, 30 MW, 40 MW, 50 MW and 60 MW were simulated to investigate the influence of the water spray flow rate (0 L/min, 200 L/min, 300 L/min, 400 L/min, 500 L/min and 600 L/min) and spray angle (30 degrees, 60 degrees, 90 degrees, 120 degrees and 150 degrees) on the critical velocity by Fire Dynamics Simulator (FDS). The simulation data of the case without a water spray system were compared with previous studies and agreed well with previous model. However, previous model overestimates the critical velocity in the cases with a water spray system. The critical velocity decreases with the increase of water spray flow rate, while it increases firstly and then decreases with the increase of the spray angle. The change of the critical velocity is illustrated with the flow field and is caused by both the cooling effect of the water spray and inertial force of the longitudinal flow. Furthermore, a new correlation was proposed to predict the critical velocity in the tunnel with water spray system by introducing a modified coefficient ss representing the water spray flow rate effect. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Study of the critical velocity in tunnels with longitudinal ventilation and spray systems
    Tang, Z.
    Liu, Y. J.
    Yuan, J. P.
    Fang, Z.
    FIRE SAFETY JOURNAL, 2017, 90 : 139 - 147
  • [2] Influence of the water spray particle diameter and flow rate on the smoke flow and the back-layering in tunnels with longitudinal ventilation
    Gao, Zihe
    Wang, Pu
    Cai, Jiajun
    Liu, Mingge
    Li, Linjie
    INDOOR AND BUILT ENVIRONMENT, 2024, 33 (05) : 843 - 858
  • [3] Influence of longitudinal ventilation on the mass flow rate distribution of fire smoke flow in tunnels
    Wang, Junheng
    Fang, Zheng
    Tang, Zhi
    Yuan, Jianping
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 112
  • [4] Influence of ambient pressure on critical ventilation velocity and backlayering distance of thermal driven smoke in tunnels with longitudinal ventilation
    Guo, Fangyi
    Gao, Zihe
    Wan, Huaxian
    Ji, Jie
    Yu, Longxing
    Ding, Long
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2019, 145
  • [5] A study on the effects of the slope on the critical velocity for longitudinal ventilation in tilted tunnels
    Li, J.
    Li, Y. F.
    Cheng, C. H.
    Chow, W. K.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2019, 89 : 262 - 267
  • [6] Discussions on critical velocity and critical Froude number for smoke control in tunnels with longitudinal ventilation
    Li, Ying Zhen
    Ingason, Haukur
    FIRE SAFETY JOURNAL, 2018, 99 : 22 - 26
  • [7] Critical velocity and burning rate in pool fire during longitudinal ventilation
    Roh, Jae Seong
    Ryou, Hong Sun
    Kim, Dong Hyeon
    Jung, Woo Sung
    Jang, Yong Jun
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2007, 22 (03) : 262 - 271
  • [8] The influence of longitudinal ventilation systems on fires in tunnels
    Carvel, RO
    Beard, AN
    Jowitt, PW
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2001, 16 (01) : 3 - 21
  • [9] A Study of the Critical Velocity of Smoke Bifurcation Flow in Tunnel with Longitudinal Ventilation
    Zhong, Wei
    Duanmu, Weike
    Wang, Tao
    Liang, Tianshui
    FIRE TECHNOLOGY, 2017, 53 (02) : 873 - 891
  • [10] A Study of the Critical Velocity of Smoke Bifurcation Flow in Tunnel with Longitudinal Ventilation
    Wei Zhong
    Weike Duanmu
    Tao Wang
    Tianshui Liang
    Fire Technology, 2017, 53 : 873 - 891