Mapping skin using Raman spectroscopy

被引:0
作者
Villanueva-Luna, A. E. [1 ]
Castro-Ramos, J. [1 ]
Vazquez-Montiel, S. [1 ]
Flores-Gil, A. [2 ]
Delgado-Atencio, J. A. [1 ]
Ortiz-Lima, C. M. [1 ]
机构
[1] Inst Nacl Astrofis Opt & Electr, Dept Opt, Luis Enrique Erro 1 Tonantzintla, Puebla, Mexico
[2] Univ Autonoma Carmen, Fac Ingn, Campeche, Mexico
来源
OPTICAL DIAGNOSTICS AND SENSING XI: TOWARD POINT-OF-CARE DIAGNOSTICS AND DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE III | 2011年 / 7906卷
关键词
Raman spectroscopy; point to point method; skin; MICROSCOPY; LINE;
D O I
10.1117/12.874268
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this work we carried out a comparison and localization of skin Raman spectra. Measurements were made in regions where Raman scatter is caused by the excitation source; we used the spectra overlap in a comparative way. Ten volunteers with different skin colors participated in the experiment; body parts sampled were palm and dorsum of the hand. The excitation wavelength used for this work was 785nm. A spectrometer with 6cm(-1) resolution and spectral region range 0 to 2000 cm(-1) was utilized. We used Matlab (R) to overlap and compare the differences between Raman spectra form different samples. We found spectral variations that were caused by differences on the surface of the skin, such as scars and moles. This work helps to identify potential undesirable behavior on the epidermis.
引用
收藏
页数:7
相关论文
共 14 条
[1]   Identification of secondary metabolites in medicinal and spice plants by NIR-FT-Raman microspectroscopic mapping [J].
Baranska, M ;
Schulz, H ;
Rösch, P ;
Strehle, MA ;
Popp, J .
ANALYST, 2004, 129 (10) :926-930
[2]   MOLECULAR IMAGING BY RAMAN MICROSCOPY [J].
BATCHELDER, DN ;
CHENG, CW ;
PITT, GD .
ADVANCED MATERIALS, 1991, 3 (11) :566-568
[3]   Hyperspectral Raman microscopic imaging using Powell lens line illumination [J].
Christensen, KA ;
Morris, MD .
APPLIED SPECTROSCOPY, 1998, 52 (09) :1145-1147
[4]  
Hutchings J., 2010, ADV RES IND
[5]   Raman and infrared spectroscopic mapping of human primary intracranial tumors: a comparative study [J].
Krafft, C ;
Sobottka, SB ;
Schackert, G ;
Salzer, R .
JOURNAL OF RAMAN SPECTROSCOPY, 2006, 37 (1-3) :367-375
[6]   Methodology for fiber-optic Raman mapping and FTIR imaging of metastases in mouse brains [J].
Krafft, Christoph ;
Kirsch, Matthias ;
Beleites, Claudia ;
Schackert, Gabriele ;
Salzer, Reiner .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (04) :1133-1142
[7]   A MINIATURIZED, NO-MOVING-PARTS RAMAN SPECTROMETER [J].
LEWIS, EN ;
TREADO, PJ ;
LEVIN, IW .
APPLIED SPECTROSCOPY, 1993, 47 (05) :539-543
[8]  
Macleod NA, 2010, BIOL MED PHYS BIOMED, P47, DOI 10.1007/978-3-642-02649-2_3
[9]   IMAGING SPECTROMETERS FOR FLUORESCENCE AND RAMAN MICROSCOPY - ACOUSTOOPTIC AND LIQUID-CRYSTAL TUNABLE FILTERS [J].
MORRIS, HR ;
HOYT, CC ;
TREADO, PJ .
APPLIED SPECTROSCOPY, 1994, 48 (07) :857-866
[10]   Raman microspectroscopy:: A comparison of point, line, and wide-field imaging methodologies [J].
Schlücker, S ;
Schaeberle, MD ;
Huffman, SW ;
Levin, IW .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4312-4318