Investigation of the release behavior of cupric ion for three types of Cu-IUDs and indomethacin for medicated Cu-IUD in simulated uterine fluid

被引:40
作者
Liang, Jinying [1 ]
Li, Ying [2 ]
Gu, Xuan [1 ]
Gao, Yanli [1 ]
Liu, Hanping [1 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut, Nanjing 210009, Peoples R China
[2] Inst Planned Parenthood Res Jiangsu Prov, Nanjing 210036, Peoples R China
关键词
Cu-IUD; mediated Cu-IUD; cupric ion; indomethacin; simulated uterine fluid; release behavior;
D O I
10.1016/j.contraception.2007.12.005
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: A number of copper-bearing intrauterine devices (Cu-IUDs) are now commercially available in China. The release behavior of cupric ion from Cu-IUDs is essential to the success of contraception, and the release behavior of indomethacin from medicated Cu-IUD is related to its therapeutic effect. Study Design: In this study, analytical methods were established to investigate the release behavior of cupric ion of three existing types of Cu-IUDs and indomethacin of one medicated Cu-IUD (Yuangong 365 Cu-IUD). Cu-IUDs were incubated in simulated uterine fluid (SUF). The concentrations of cupric ion and indomethacin were analyzed by flame atomic absorption spectrometer (FAAS) for 250 days and UV 752 spectrophotometer for 300 days, respectively. Results: The release behavior of cupric ion for three types of Cu-IUDs was biphasic, which consisted of the initial burst release and then slow and constant release. The release of cupric ion from the medicated Cu-IUD Yuangong 365 showed a zero-order process. In vitro release experiment confirmed a sustained release of indomethacin from Yuangong 365 and the release was in accordance with the Weibull equation. Conclusion: The cupric ion release appears to be more constant in the medicated Cu-IUD than in the others. In view of the feature of indomethacin release from medicated Cu-IUD, it is conjectured that the design of this device could be useful to avoid the adverse effects caused by all Cu-IUDs. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:299 / 302
页数:4
相关论文
共 21 条
[1]   Copper corrosion inhibition by triphenylmethane derivatives in sulphuric acid media [J].
Bastidas, JM ;
Pinilla, P ;
Cano, E ;
Polo, JL ;
Miguel, S .
CORROSION SCIENCE, 2003, 45 (02) :427-449
[2]  
[蔡水洲 Cai Shuizhou], 2004, [生殖与避孕, Reproduction and Contraception], V24, P299
[3]   Corrosion behavior of copper/LDPE nanocomposites in simulated uterine solution [J].
Cai, SZ ;
Xia, XP ;
Xie, CS .
BIOMATERIALS, 2005, 26 (15) :2671-2676
[4]   Worldwide use of intrauterine devices for contraception [J].
d'Arcangues, Catherine .
CONTRACEPTION, 2007, 75 (06) :S2-S7
[5]   CORROSION OF A NEW COPPER-GOLD OR COPPER-PLATINUM INTRAUTERINE-DEVICE [J].
GALOR, L ;
GONEN, R ;
ZILBERMAN, A ;
SCHARF, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1982, 16 (06) :785-798
[6]  
GAO J, 2006, REPROD CONTRACEPT, V26, P602
[7]  
GIBOR Y, 1973, J REPROD MED, V11, P209
[8]   Cochrane systematic reviews of IUD trials: lessons learned [J].
Grimes, David A. ;
Lopez, Laureen A. ;
Manion, Carol ;
Schulz, Kenneth F. .
CONTRACEPTION, 2007, 75 (06) :S55-S59
[9]   A preliminary morphometric study on the endometrium from patients treated with indomethacin-releasing copper intrauterine device [J].
Gu, Z ;
Li, MS ;
Zhu, PD ;
Xu, RH ;
Wang, JD ;
Xu, RQ .
HUMAN REPRODUCTION, 1997, 12 (07) :1563-1566
[10]   COPPER RELEASE FROM COPPER INTRAUTERINE-DEVICES REMOVED AFTER UP TO 8 YEARS OF USE [J].
KJAER, A ;
LAURSEN, K ;
THORMANN, L ;
BORGGAARD, O ;
LEBECH, PE .
CONTRACEPTION, 1993, 47 (04) :349-358