Accuracy of Ultrasound in Diagnosis of Pneumothorax: A Comparison between Neonates and Adults-A Systematic Review and Meta-Analysis

被引:41
作者
Dahmarde, Hamid [1 ]
Parooie, Fateme [2 ]
Salarzaei, Morteza [2 ]
机构
[1] Zahedan Univ Med Sci, Fac Med, Dept Radiol, Zahedan, Iran
[2] Zabol Univ Med Sci, Students Res Comm, Zabol, Iran
关键词
RESPIRATORY-DISTRESS-SYNDROME; TRAUMATIC PNEUMOTHORAX; LUNG ULTRASOUND; TRANSTHORACIC SONOGRAPHY; TRANSIENT TACHYPNEA; BEDSIDE SONOGRAPHY; CHEST RADIOGRAPHY; CRITICALLY-ILL; ULTRASONOGRAPHY; POINT;
D O I
10.1155/2019/5271982
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Objective. The present systematic review and meta-analysis were conducted to investigate the accuracy of ultrasound in the diagnosis of pneumothorax in neonates and adults. Method. The searches were conducted by two independent researchers (MS and HD) to find the relevant studies published from 01/01/2009 until the end of 01/01/2019. We searched for published literature in the English language in MEDLINE via PubMed, Embase (TM) via ovid, the Cochrane Library, and Trip database. For literature published in other languages, we searched national databases (Magiran and SID), KoreaMed, and LILACS, and we searched OpenGrey () and the World Health Organization Clinical Trials Registry () for unpublished literature and ongoing studies. The keywords used in the search strategy were pneumothorax or ultrasound or chest ultrasonography or neonate or adult or aerothorax or sensitivity or specificity or diagnostic accuracy. The list of previous study resources and systematic reviews was also searched for identifying the published studies (MS and HD). Analyses were performed using Meta-Disc 1.4. Results. In total, 1,565 patients (255 neonates, 1212 adults, and 101 pediatrics suspected of pneumothorax) were investigated in 10 studies. The overall specificity of chest ultrasound in the diagnosis of pneumothorax in both populations of adults and neonates was 85.1% at the confidence interval of 95 percent (95% CI 81.1%-88.5%). At the confidence interval of 95 percent, the sensitivity was 98.6% (95% CI 97.7%-99.2%). The diagnostic odds ratio was 387.72 (95% CI 76.204-1972.7). For the diagnosis of pneumothorax in neonates, the ultrasound sensitivity was 96.7% at the confidence interval of 95 percent (95% CI 88.3%-99.6%). At the confidence interval of 95 percent, the specificity was 100% (95% CI 97.7%-100%). For the diagnosis of pneumothorax in adults, the ultrasound sensitivity was 82.9% at the confidence interval of 95 percent (95% CI 78.3-86.9%). At the confidence interval of 95 percent, the specificity was 98.2% (95% CI 97.0%-99.0%). The diagnostic odds ratio was 423.13 (95% CI 45.222-3959.1). Analyzing studies indicated that the sensitivity of "absence lung sliding" sign for the diagnosis of pneumothorax was 87.2% (95% CI 77.7-93.7), and specificity was 99.4% (95% CI 96.5%-100%). DOR was 556.74 (95% CI 100.03-3098.7). The sensitivity of "lung point" sign for the diagnosis of pneumothorax was 82.1% (95% CI 71.7%-89.8%), and the specificity was 100% (at the confidence interval of 95% CI 97.6%-100%). DOR was 298.0 (95% CI 58.893-1507.8). Conclusion. The diagnosis of pneumothorax using ultrasound is accurate and reliable; additionally, it can result in timely diagnoses specifically in neonatal pneumothorax. Using this method facilitates the therapy process; lack of ionizing radiation and easy operation are benefits of this imaging technique.
引用
收藏
页数:16
相关论文
共 46 条
[1]   Accuracy of emergency physician-performed ultrasound in detecting traumatic pneumothorax after a 2-h training course [J].
Abbasi, Saeed ;
Farsi, Davood ;
Hafezimoghadam, Peyman ;
Fathi, Marzieh ;
Zare, Mohammad A. .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2013, 20 (03) :173-177
[2]   Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: review of the literature and meta-analysis [J].
Alrajab, Saadah ;
Youssef, Asser M. ;
Akkus, Nuri I. ;
Caldito, Gloria .
CRITICAL CARE, 2013, 17 (05)
[3]   Test Characteristics of Ultrasonography for the Detection of Pneumothorax A Systematic Review and Meta-analysis [J].
Alrajhi, Khaled ;
Woo, Michael Y. ;
Vaillancourt, Christian .
CHEST, 2012, 141 (03) :703-708
[4]  
[Anonymous], J PEDIAT RESP DIS
[5]  
Balesa Jitendra, 2015, Indian J Chest Dis Allied Sci, V57, P7
[6]  
Bober K, 2006, MED SCI MONITOR, V12, pCR440
[7]   Lung Ultrasound Diagnostic Accuracy in Neonatal Pneumothorax [J].
Cattarossi, Luigi ;
Copetti, Roberto ;
Brusa, Giacomo ;
Pintaldi, Stefano .
CANADIAN RESPIRATORY JOURNAL, 2016, 2016
[8]   Routine application of lung ultrasonography in the neonatal intensive care unit [J].
Chen, Shui-Wen ;
Fu, Wei ;
Liu, Jing ;
Wang, Yan .
MEDICINE, 2017, 96 (02)
[9]   Lung ultrasound in respiratory distress syndrome: A useful tool for early diagnosis [J].
Copetti, Roberto ;
Cattarossi, Luigi ;
Macagno, Franco ;
Violino, Marco ;
Furlan, Riccardo .
NEONATOLOGY, 2008, 94 (01) :52-59
[10]   The 'double lung point': An ultrasound sign diagnostic of transient tachypnea of the newborn [J].
Copetti, Roberto ;
Cattarossi, Luigi .
NEONATOLOGY, 2007, 91 (03) :203-209