A review of radiation dosimetry applications using the MCNP Monte Carlo code

被引:35
作者
Solberg, TD [1 ]
DeMarco, JJ [1 ]
Chetty, IJ [1 ]
Mesa, AV [1 ]
Cagnon, CH [1 ]
Li, AN [1 ]
Mather, KK [1 ]
Medin, PM [1 ]
Arellano, AR [1 ]
Smathers, JB [1 ]
机构
[1] Univ Calif Los Angeles, Sch Med, Dept Radiat Oncol, Los Angeles, CA 90095 USA
关键词
Monte Carlo; MCNP; radiation dosimetry; medical physics; treatment planning;
D O I
10.1524/ract.2001.89.4-5.337
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The Monte Carlo code MCNP (Monte Carlo N-Particle) has a significant history dating to the early years of the Manhattan Project. More recently, MCNP has been used successfully to solve many problems in the field of medical physics. In radiotherapy applications MCNP has been used successfully to calculate the bremsstrahlung spectra from medical linear accelerators, for modeling the dose distributions around high dose rate brachytherapy sources, and for evaluating the dosimetric properties of new radioactive sources used in intravascular irradiation for prevention of restenosis following angioplasty. MCNP has also been used for radioimmunotherapy and boron neutron capture therapy applications. It has been used to predict fast neutron activation of shielding and biological materials. One area that holds tremendous clinical promise is that of radiotherapy treatment planning. In diagnostic applications, MCNP has been used to model X-ray computed tomography and positron emission tomography scanners, to compute the dose delivered from CT procedures, and to determine detector characteristics of nuclear medicine devices. MCNP has been used to determine particle fluxes around radiotherapy treatment devices and to perform shielding calculations in radiotherapy treatment rooms. This manuscript is intended to provide to the reader a comprehensive summary of medical physics applications of the MCNP code.
引用
收藏
页码:337 / 355
页数:19
相关论文
共 110 条
[1]   NEUTRON FLUXES IN RADIOTHERAPY ROOMS [J].
AGOSTEO, S ;
PARA, AF ;
MAGGIONI, B .
MEDICAL PHYSICS, 1993, 20 (02) :407-414
[2]   Estimation of the dose at the maze entrance for x-rays from radiotherapy linear accelerators [J].
Al-Affan, IAM .
MEDICAL PHYSICS, 2000, 27 (01) :231-238
[3]   MEAN ENERGY IN ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A .
MEDICAL PHYSICS, 1981, 8 (05) :682-687
[4]   MONTE-CARLO TECHNIQUES IN MEDICAL RADIATION PHYSICS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (07) :861-920
[5]  
[Anonymous], 1988, MONTE CARLO TRANSPOR
[6]  
[Anonymous], 1974, IIE Transactions
[7]  
ARELLANO AR, 1996, MED PHYS, V23, P1492
[8]  
Berger M, 1963, METHODS COMPUTATIONA, VI
[9]  
BERGER MJ, 1968, CCC107 RAD SHIELD IN
[10]   Designing accelerator-based epithermal neutron beams for boron neutron capture therapy [J].
Bleuel, DL ;
Donahue, RJ ;
Ludewigt, BA ;
Vujic, J .
MEDICAL PHYSICS, 1998, 25 (09) :1725-1734