A comparison of vacuum and direct contact membrane distillation for phosphorus and ammonia recovery from wastewater

被引:30
作者
Simoni, Gustav [1 ]
Kirkebaek, Bastian Stiem [1 ]
Quist-Jensen, Cejna Anna [1 ]
Christensen, Morten Lykkegaard [1 ]
Ali, Aamer [1 ]
机构
[1] Aalborg Univ, Ctr Membrane Technol, Dept Chem & Biosci, Fredr Bajers Vej 7H, DK-9220 Aalborg, Denmark
关键词
Wastewater; Phosphorus; ammonia; Direct contact membrane distillation; Vacuum membrane distillation; REMOVAL; CRYSTALLIZATION; DESALINATION; NITROGEN; MD;
D O I
10.1016/j.jwpe.2021.102350
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recovery of ammonia (NH3) and phosphorous (P) from municipal wastewater is important to minimize the environmental impact of their discharge and to comply with the concept of circular economy. Technologies have been established to recover P in form of struvite (MgNH4PO4.6H2O) for its use as a fertilizer. NH3 is usually converted to molecular nitrogen and released to the atmosphere; however, NH3 recovery in form of NH3/H2O mixture is relevant for numerous applications such as manufacturing of cleaning agents, sanitizers and liquid fertilizers. Membrane distillation (MD), a process driven by the partial vapor pressure across a microporous hydrophobic membrane, has demonstrated the potential for concentrating the non-volatiles while, at the same time, recovering volatiles from a solution. Among various configurations of MD, vacuum and direct contact MD (DCMD) have been extensively studied. The current study compares the performance of DCMD and vacuum MD (VMD) for simultaneous recovery of NH3 and P from wastewater in form of NH3/H2O mixture and struvite, respectively. The study finds that while both the configuration are equally effective to concentrate P, the control over removal efficiency of NH3 in the two configurations becomes the bottleneck for struvite recovery under different pH conditions. For wastewater with high pH, VMD almost completely removes NH3 before reaching substantial P concentration, thereby eliminates the possibility of struvite formation. DCMD on other hand, only partly removes NH3 while concentrating P, therefore, for struvite recovery from a high pH wastewater, DCMD is better option. For low pH wastewater, VMD is preferred choice as it recovers NH3 more effectively than DCMD but still leaves ample NH3 in the wastewater for struvite formation.
引用
收藏
页数:14
相关论文
共 50 条
[11]   Influence of dye class on the comparison of direct contact and vacuum membrane distillation applied to remediation of dyeing wastewater [J].
Ramlow, Heloisa ;
Francisco Machado, Ricardo Antonio ;
Krause Bierhalz, Andrea Cristiane ;
Marangoni, Cintia .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2019, 54 (13) :1337-1347
[12]   Influences of Permeate Solution and Feed pH on Enhancement of Ammonia Recovery from Wastewater by Negatively Charged PTFE Membranes in Direct Contact Membrane Distillation Operation [J].
Kywe, Pyae Phyo ;
Ratanatamskul, Chavalit .
ACS OMEGA, 2022, 7 (31) :27722-27733
[13]   Vacuum membrane distillation multi-component numerical model for ammonia recovery from liquid streams [J].
Scheepers, D. M. ;
Tahir, A. J. ;
Brunner, C. ;
Guillen-Burrieza, E. .
JOURNAL OF MEMBRANE SCIENCE, 2020, 614
[14]   Simultaneous recovery of phosphorus and nitrogen from liquid digestate by vacuum membrane distillation with permeate fractional condensation [J].
Qiu, Boya ;
Fan, Senqing ;
Tang, Xiaoyu ;
Qi, Bufan ;
Deng, Liangwei ;
Wang, Wenguo ;
Liu, Jingyun ;
Wang, Yuyang ;
Xiao, Zeyi .
CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2020, 28 (06) :1558-1565
[15]   Treatment of radioactive wastewater using direct contact membrane distillation [J].
Liu, Haiyang ;
Wang, Jianlong .
JOURNAL OF HAZARDOUS MATERIALS, 2013, 261 :307-315
[16]   Sustainable ammonia resource recovery from landfill leachate by solar-driven modified direct contact membrane distillation [J].
Zico, M. M. ;
Ricci, B. C. ;
Reis, B. G. ;
Magalhaes, N. C. ;
Amaral, M. C. S. .
SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 264
[17]   Direct contact membrane distillation with heat recovery: Thermodynamic insights from module scale modeling [J].
Lin, Shihong ;
Yip, Ngai Yin ;
Elimelech, Menachem .
JOURNAL OF MEMBRANE SCIENCE, 2014, 453 :498-515
[18]   AMMONIA REMOVAL FROM SALINE WATER BY DIRECT CONTACT MEMBRANE DISTILLATION [J].
Sarbatly, Rosalam ;
Chiam, Chel-Ken .
SUSTAINABLE MEMBRANE TECHNOLOGY FOR ENERGY, WATER, AND ENVIRONMENT, 2012, :309-317
[19]   Relating water vapor transfer to ammonia recovery from biogas slurry by vacuum membrane distillation [J].
He, Qingyao ;
Tu, Te ;
Yan, Shuiping ;
Yang, Xing ;
Duke, Mikel ;
Zhang, Yanlin ;
Zhao, Shuaifei .
SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 191 :182-191
[20]   Influence of solution and operating conditions on the treatment of aquaculture wastewater using direct contact membrane distillation: Ammonia rejection and membrane fouling [J].
Zhang, Bing ;
Shen, Jing ;
Xiong, Jianhui ;
Shen, Yu ;
Zhang, Bing ;
Shi, Wenxin .
CHEMICAL ENGINEERING JOURNAL, 2023, 478