A voltammetric immunosensor based on nanobiocomposite materials for the determination of alpha-fetoprotein in serum

被引:67
作者
Giannetto, Marco [1 ]
Elviri, Lisa [1 ]
Careri, Maria [1 ]
Mangia, Alessandro [1 ]
Mori, Giovanni [1 ]
机构
[1] Univ Parma, Dipartimento Chim Gen & Inorgan, I-43124 Parma, Italy
关键词
Biosensors; Immunoassay; Nanoparticles; AFP; Validation; Serum; IONIC LIQUID; IMMUNOASSAY; VALIDATION; BIOMARKER; COMPOSITE; BIOSENSOR; ELECTRODE;
D O I
10.1016/j.bios.2010.09.040
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The development of a voltammetric immunosensor for determination of alpha-fetoprotein (AFP) in serum is presented. ELISA assays with voltammetric reading were carried out exploiting the peculiar properties of nanobiocomposite materials based on gold nanoparticles for the immobilization of Antibody (Ab)/Antigen/Antibody-HRP (Horseradish Peroxidase) sandwich on the glassy carbon (GC) electrode surface. The electrochemical transduction was mediated by thionin, which was used in its monomeric form dissolved in the reading solution, so avoiding critical immobilization procedures. The study was aimed at the development and validation of an immunosensor able to provide results in short time, simple to use, rugged and cost-effective for AFP monitoring purposes. A crucial aspect of the study was the development of an experimental protocol leading to highly standardized and consequently reproducible sensors. Two-way analysis of variance (ANOVA) was applied to study the effect of the concentration of the solutions used for the incubation of the antibodies. The sensor was validated in serum assessing stability of the immunocomplex, linearity of response, limit of detection (3.7 ng/ml) and limit of quantitation (11 ng/ml), precision (intra- and inter-sensor repeatability) and recovery rate (103%). The stability of the GC/Ab functionalized substrate was demonstrated over one month, showing variation coefficients below 5%. Experiments carried out with real samples of clinical interest evidenced that the developed immunosensor can be considered as powerful tool in cancer screening programmes. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2232 / 2236
页数:5
相关论文
共 23 条
[1]  
[Anonymous], 2009, MOSBYS MED DICT
[2]  
[Anonymous], 1964, The Statistical Analysis of Experimental Data
[3]   Multiple biomarker use for detection of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome [J].
Apple, Fred S. ;
Pearce, Lesly A. ;
Chung, Adrine ;
Ler, Ranka ;
Murakami, MaryAnn M. .
CLINICAL CHEMISTRY, 2007, 53 (05) :874-881
[4]   Analysis of soyabean proteins in meat products.: A review [J].
Belloque, J ;
García, MC ;
Torre, M ;
Marina, ML .
CRITICAL REVIEWS IN FOOD SCIENCE AND NUTRITION, 2002, 42 (05) :507-532
[5]   LC-MS/MS quantification of Zn-α2 glycoprotein:: A potential serum biomarker for prostate cancer [J].
Bondar, Olga P. ;
Barnidge, David R. ;
Klee, Eric W. ;
Davis, Brian J. ;
Klee, George G. .
CLINICAL CHEMISTRY, 2007, 53 (04) :673-678
[6]   Applications of Nanoparticles in Biology [J].
De, Mrinmoy ;
Ghosh, Partha S. ;
Rotello, Vincent M. .
ADVANCED MATERIALS, 2008, 20 (22) :4225-4241
[7]   An electrochemical biosensor for α-fetoprotein based on carbon paste electrode constructed of room temperature ionic liquid and gold nanoparticles [J].
Ding, Caifeng ;
Zhao, Fei ;
Ren, Rui ;
Lin, Jin-Ming .
TALANTA, 2009, 78 (03) :1148-1154
[8]   Electrochemical immunoassay for based on polythionine and gold glassy carbon electrodes carbohydrate antigen-125 hollow microspheres modified [J].
Fu, Xiao-Hong .
ELECTROANALYSIS, 2007, 19 (17) :1831-1839
[9]  
Funk W., 1995, Quality Assurance in Analytical Chemistry
[10]   A sensitive amperometric immunosensor for carcinoembryonic antigen detection with porous nanogold film and nano-Au/chitosan composite as immobilization matrix [J].
He, Xiulan ;
Yuan, Ruo ;
Chai, Yaqin ;
Shi, Yintao .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2008, 70 (06) :823-829