Comparison of Energyplus Simulation Results of Double Skin Facade System with CFD and Experiment Data

被引:1
作者
Mun, Junghyon [1 ]
Lee, Jongik [1 ]
Koh, Brian Baewon [1 ]
机构
[1] R&D Ctr Sun&Light, Seoul, South Korea
来源
PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA | 2020年
关键词
PERFORMANCE;
D O I
10.26868/25222708.2019.210237
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The purpose of this paper is to make a building simulation model for the double skin facade system using Energyplus and optimize the model using CFD(Computational Fluid Dynamics) and experimental data. When conducting the double skin facade simulation using Energyplus, it is required to select a proper solar distribution model which allows the beam solar radiation to be transmitted into the adjacent zone correctly. In addition, interzone heat and air transfer between the cavity space of the double skin facade system and the adjacent living space should be modelled correctly. Discharge coefficient calculation is an important process in making a building simulation when windows of the double skin facade system open. Discharge coefficient can be determined using experimental data but if the experiment data are not sufficient enough, CFD analysis can be used to get the coefficients. The wind pressure coefficients can also be obtained using CFD.
引用
收藏
页码:4110 / 4117
页数:8
相关论文
共 13 条
[1]  
Alexandra P., 2008, ENERGY BUILDING, V40, P466
[2]   Investigation on energy performance of double skin facade in Hong Kong [J].
Chan, A. L. S. ;
Chow, T. T. ;
Fong, K. F. ;
Lin, Z. .
ENERGY AND BUILDINGS, 2009, 41 (11) :1135-1142
[3]  
Department of Energy, 2018, ENERGYPLUS INP OUTP
[4]  
Department of Energy, 2018, ENERGYPLUS ENG REF
[5]  
Diego A., 2015, P IBPC2015 6 INT BUI
[6]   Natural ventilation for passive cooling: measurement of discharge coefficients [J].
Flourentzou, F ;
Van der Maas, J ;
Roulet, CA .
ENERGY AND BUILDINGS, 1998, 27 (03) :283-292
[7]   Optimal operation of a south double-skin facade [J].
Gratia, E ;
De Herde, A .
ENERGY AND BUILDINGS, 2004, 36 (01) :41-60
[8]   Are energy consumptions decreased with the addition of a double-skin? [J].
Gratia, Elisabeth ;
De Herde, Andre .
ENERGY AND BUILDINGS, 2007, 39 (05) :605-619
[9]  
Hamza N., 2005, ENERG BUILDINGS, V37, P536
[10]  
Jang M. K., 2016, P SAREK 2016 SOC AIR