The PEARL-DGS Formula: The Development of an Open-source Machine Learning-based Thick IOL Calculation Formula

被引:61
作者
Debellemaniere, Guillaume [1 ]
Dubois, Mathieu [1 ]
Gauvin, Mathieu [2 ,3 ]
Wallerstein, Avi [2 ,3 ]
Brenner, Luis F. [4 ]
Rampat, Radhika [1 ]
Saad, Alain [1 ]
Gatinel, Damien [1 ]
机构
[1] Rothschild Fdn Hosp, Dept Ophthalmol, Paris, France
[2] McGill Univ, Dept Ophthalmol & Visual Sci, Montreal, PQ, Canada
[3] LASIK MD, Montreal, PQ, Canada
[4] Memira Eye Ctr, Oslo, Norway
关键词
INTRAOCULAR-LENS CALCULATION; POWER CALCULATION; REFRACTIVE-INDEX; ACCURACY; EYES;
D O I
10.1016/j.ajo.2021.05.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To describe an open-source, reproducible, step-by-step method to design sum-of-segments thick intraocular lens (IOL) calculation formulas, and to evaluate a formula built using this methodology. DESIGN: Retrospective, multicenter case series METHODS: A set of 4242 eyes implanted with Finevision IOLs (PhysIOL, Liege, Belgium) was used to devise the formula design process and build the formula. A different set of 677 eyes from the same center was kept separate to serve as a test set. The resulting formula was evaluated on the test set as well as another independent data set of 262 eyes. RESULTS: The lowest standard deviation (SD) of prediction errors on Set 1 were obtained with the PEARL-DGS formula (+/- 0.382 D), followed by K6 and Olsen (+/- 0.394 D), EVO 2.0 (+/- 0.398 D), RBF 3.0, and BUII (+/- 0.402 D). The formula yielding the lowest SD on Set 2 was the PEARL-DGS (+/- 0.269 D), followed by Olsen (+/- 0.272 D), K6 (+/- 0.276 D), EVO 2.0 (+/- 0.277 D), and BUII (+/- 0.301 D). CONCLUSION: Our methodology achieved an accuracy comparable to other state-of-the-art IOL formulas. The open-source tools provided in this article could allow other researchers to reproduce our results using their own data sets, with other IOL models, population settings, biometric devices, and measured, rather than calculated, posterior corneal radius of curvature or sum-of-segments axial lengths. ((C) 2021 Published by Elsevier Inc.)
引用
收藏
页码:58 / 69
页数:12
相关论文
共 45 条
[1]   Optical models for human myopic eyes [J].
Atchison, David A. .
VISION RESEARCH, 2006, 46 (14) :2236-2250
[3]   In vivo measurement of the human crystalline lens equivalent refractive index using extended-depth OCT [J].
Chang, Yu-Cherng ;
Mesquita, Gabrielle Monterano ;
Williams, Siobhan ;
Gregori, Giovanni ;
Cabot, Florence ;
Ho, Arthur ;
Ruggeri, Marco ;
Yoo, Sonia H. ;
Parel, Jean-Marie ;
Manns, Fabrice .
BIOMEDICAL OPTICS EXPRESS, 2019, 10 (02) :411-422
[4]   Refractive Predictability Using the IOLMaster 700 and Artificial Intelligence-Based IOL Power Formulas Compared to Standard Formulas [J].
Cheng, Huanhuan ;
Kane, Jack X. ;
Liu, Liangping ;
Li, Jianbing ;
Cheng, Bing ;
Wu, Mingxing .
JOURNAL OF REFRACTIVE SURGERY, 2020, 36 (07) :466-+
[5]   Comparison of the Kane formula with existing formulas for intraocular lens power selection [J].
Connell, Benjamin J. ;
Kane, Jack X. .
BMJ OPEN OPHTHALMOLOGY, 2019, 4 (01)
[6]  
Cooke D, 2021, COOK FORM K6
[7]   Approximating sum-of-segments axial length from a traditional optical low-coherence reflectometry measurement [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (03) :351-354
[8]   Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service [J].
Darcy, Kieren ;
Gunn, David ;
Tavassoli, Shokufeh ;
Sparrow, John ;
Kane, Jack X. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) :2-7
[9]  
Debellemaniere G, 2021, IOL SOLVER
[10]   New Approach for the Calculation of the Intraocular Lens Power Based on the Fictitious Corneal Refractive Index Estimation [J].
Fernandez, Joaquin ;
Rodriguez-Vallejo, Manuel ;
Martinez, Javier ;
Tauste, Ana ;
Pinero, David P. .
JOURNAL OF OPHTHALMOLOGY, 2019, 2019