A quantum dot-aptamer beacon using a DNA intercalating dye as the FRET reporter: Application to label-free thrombin detection

被引:93
作者
Chi, Chun-Wei [1 ]
Lao, Yeh-Hsing [1 ]
Li, Yi-Shan [1 ]
Chen, Lin-Chi [1 ]
机构
[1] Natl Taiwan Univ, Dept Bioind Mech Engn, Taipei 10764, Taiwan
关键词
Aptamer beacon; BOBO-3; Quadruplex; Quantum dot; Thrombin; SEMICONDUCTOR NANOCRYSTALS; MOLECULAR BEACONS; PROTEIN; SWITCH; OPTIMIZATION; COMPLEX; BINDING; BLOOD; SERUM;
D O I
10.1016/j.bios.2011.01.015
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A new quantum dot (QD)-aptamer (apt) beacon that acts by folding-induced dissociation of a DNA intercalating dye, BOBO-3(B), is demonstrated with label-free thrombin detection. The beacon, denoted as QD-apt:B, is constructed by (1) coupling of a single-stranded thrombin aptamer to Qdot 565 via EDC/Sulfo-NHS chemistry and (2) staining the duplex regions of the aptamer on QD with excess BOBO-3 before thrombin binding. When mixing a thrombin sample with QD-apt:B, BOBO-3 is competed away from the beacon due to target-induced aptamer folding, which then causes a decrease in QD fluorescence resonance energy transfer (FRET)-mediated BOBO-3 emission and achieves thrombin quantitation. In this work, the effects of Mg2+, coupling time, and aptamer type on the beacon's performances are investigated and discussed thoroughly with various methods, including transmission electron microscopy (TEM), dynamic light scattering (DLS), and two-color differential gel electrophoresis. Using the best aptamer beacon (HTQ37), we attain highly specific and wide-range detection (from nm to mu M) of thrombin in buffer, and the beacon can sense nM-range thrombin in 15% diluted serum. Compared to the reported QD aptamer assays, our method is advantageous from the aspect of using a simple sensory unit design without losing the detection sensitivity. Therefore, we consider the QD-apt:B beacon a potential alternative to immuno-reagents and an effective tool to study nucleic acid folding on QD as well. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3346 / 3352
页数:7
相关论文
共 36 条
  • [1] Aptasensor development: Elucidation of critical parameters for optimal aptamer performance
    Baldrich, E
    Restrepo, A
    O'Sullivan, CK
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (23) : 7053 - 7063
  • [2] SELECTION OF SINGLE-STRANDED-DNA MOLECULES THAT BIND AND INHIBIT HUMAN THROMBIN
    BOCK, LC
    GRIFFIN, LC
    LATHAM, JA
    VERMAAS, EH
    TOOLE, JJ
    [J]. NATURE, 1992, 355 (6360) : 564 - 566
  • [3] Semiconductor nanocrystals as fluorescent biological labels
    Bruchez, M
    Moronne, M
    Gin, P
    Weiss, S
    Alivisatos, AP
    [J]. SCIENCE, 1998, 281 (5385) : 2013 - 2016
  • [4] Aptamer-Based Detection of Epithelial Tumor Marker Mucin 1 with Quantum Dot-Based Fluorescence Readout
    Cheng, Alan K. H.
    Su, Huaipeng
    Wang, Andrew
    Yu, Hua-Zhong
    [J]. ANALYTICAL CHEMISTRY, 2009, 81 (15) : 6130 - 6139
  • [5] Semiconductor quantum dots for bioanalysis
    Gill, Ron
    Zayats, Maya
    Willner, Itamar
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2008, 47 (40) : 7602 - 7625
  • [6] Aptamer beacons for the direct detection of proteins
    Hamaguchi, N
    Ellington, A
    Stanton, M
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 294 (02) : 126 - 131
  • [7] Signaling aptamer/protein binding by a molecular light switch complex
    Jiang, YX
    Fang, XH
    Bai, CL
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (17) : 5230 - 5235
  • [8] The detection of platelet derived growth factor using decoupling of quencher-oligonucleotide from aptamer/quantum dot bioconjugates
    Kim, Gang-Il
    Kim, Kyung-Woo
    Oh, Min-Kyu
    Sung, Yun-Mo
    [J]. NANOTECHNOLOGY, 2009, 20 (17)
  • [9] Adaptation of inorganic quantum dots for stable molecular beacons
    Kim, JH
    Morikis, D
    Ozkan, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2004, 102 (02): : 315 - 319
  • [10] Experimental approach for an in vitro toxicity assay with non-aggregated quantum dots
    Koeneman, Brian A.
    Zhang, Yang
    Hristovski, Kiril
    Westerhoff, Paul
    Chen, Yongsheng
    Crittenden, John C.
    Capco, David G.
    [J]. TOXICOLOGY IN VITRO, 2009, 23 (05) : 955 - 962