Measurement of total PM2.5 mass (nonvolatile plus semivolatile) with the Filter Dynamic Measurement System tapered element oscillating microbalance monitor -: art. no. D07S03

被引:97
作者
Grover, BD [1 ]
Kleinman, M
Eatough, NL
Eatough, DJ
Hopke, PK
Long, RW
Wilson, WE
Meyer, MB
Ambs, JL
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Clarkson Univ, Dept Chem Engn, Potsdam, NY 13699 USA
[3] US EPA, Res Triangle Pk, NC 27711 USA
[4] Rupprecht & Patashnick Co Inc, Albany, NY 12203 USA
关键词
D O I
10.1029/2004JD004995
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
Field studies have been performed in Lindon, Utah (February 2003) and Rubidoux, California (July 2003) to determine if the Rupprecht and Patashnick (RFP) Filter Dynamic Measurement System (FDMS) determines total fine particulate mass, including the semivolatile ammonium nitrate and organic material. Collocated measurements were made with the FDMS, a conventional tapered element oscillating microbalance (TEOM) monitor with a heated filter, an RFP differential TEOM monitor, the Brigham Young University (BYU) Real-Time Total Ambient Mass Sampler (RAMS), the BYU particle concentrator-organic sampling system (PC-BOSS), a PM2.5 Federal Reference Method (FRM), a PM2.5 speciation sampler, an RFP continuous nitrate monitor, and two Sunset continuous carbon monitors ( one to measure quartz filter-retained particulate carbon and one to measure particulate semivolatile carbonaceous material lost from the particles on a filter during sampling). The RAMS and PC-BOSS samplers have been shown to determine fine particulate material, including both the semivolatile and the nonvolatile components. Linear regression analysis at the Lindon site between the FDMS ( X) and the PC-BOSS (Y), and the FDMS (X) and the RAMS (Y), resulted in zero-intercept slopes of 1.01 +/- 0.06 (r(2) = 0.63) and 1.00 +/- 0.01 (r(2) = 0.69), respectively. At the Rubidoux sampling site, linear regression analysis between the PC-BOSS (X) and the FDMS( Y) gave a zero-intercept slope of 0.96 +/- 0.02 (r(2) = 0.90). Linear regression analysis between the FDMS (X) and the RAMS (Y) resulted in a zero-intercept slope of 0.99 +/- 0.01 (r(2) = 0.80). Measurements made at the two sites indicate that the FDMS and the RFP differential TEOM monitors do measure total fine particulate mass, including the semivolatile ammonium nitrate and organic material. Both the heated TEOM monitor and PM2.5 FRM did not measure the semivolatile material. The difference between the FDMS and a heated TEOM monitor was explained by the semivolatile ammonium nitrate and organic material measured by the various chemical composition monitors.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 16 条
[1]  
DING Y, 2001, J AEROSOL SCI TECHNO, V36, P369
[2]   Semi-volatile secondary organic aerosol in urban atmospheres: meeting a measurement challenge [J].
Eatough, DJ ;
Long, RW ;
Modey, WK ;
Eatough, NL .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (9-10) :1277-1292
[3]  
Eatough DJ, 2001, AEROSOL SCI TECH, V34, P1
[4]   APPLICATION OF THERMAL-ANALYSIS TO THE CHARACTERIZATION OF ORGANIC AEROSOL-PARTICLES [J].
ELLIS, EC ;
NOVAKOV, T .
SCIENCE OF THE TOTAL ENVIRONMENT, 1982, 23 (APR) :227-238
[5]  
GROVER BD, 2004, AWMA 97 ANN C EXH AI
[6]   Comparison of sampling methods for semi-volatile organic carbon associated with PM2.5 [J].
Lewtas, J ;
Pang, YB ;
Booth, D ;
Reimer, S ;
Eatough, DJ ;
Gundel, LA .
AEROSOL SCIENCE AND TECHNOLOGY, 2001, 34 (01) :9-22
[7]  
LONG RL, 2004, AWMA 97 ANN C EXH AI
[8]   The measurement of PM2.5, including semi-volatile components, in the EMPACT program:: results from the Salt Lake City Study [J].
Long, RW ;
Eatough, NL ;
Mangelson, NF ;
Thompson, W ;
Fiet, K ;
Smith, S ;
Smith, R ;
Eatough, DJ ;
Pope, CA ;
Wilson, WE .
ATMOSPHERIC ENVIRONMENT, 2003, 37 (31) :4407-4417
[9]  
MEYER MB, 2002, S AIR QUAL MEAS METH
[10]   Effects of equilibration temperature on PM10 concentrations from the TEOM method in the Lower Fraser Valley [J].
Mignacca, D ;
Stubbs, K .
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (10) :1250-1254