Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1

被引:10
作者
Mack, A
Mack, G
Scheib, S
Czempiel, H
Kreiner, HJ
Lomax, NJ
Gianolini, S
Rieker, M
Weltz, D
Wolff, R
Muacevic, A
Wowra, B
Böttcher, HD
Seifert, V
机构
[1] GKF GmbH, Gamma Knife Zentrum, DE-60528 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Dept Radiotherapy, Frankfurt, Germany
[3] Univ Hosp Frankfurt, Dept Neurosurg, Frankfurt, Germany
[4] Univ Tubingen, Dept Expt Phys, Tubingen, Germany
[5] PTGR GmbH, Tubingen, Germany
[6] GKS GmbH, Munich, Germany
[7] Univ Hosp Munich, Dept Neurosurg, Munich, Germany
[8] Gamma Knife Ctr Munich, Munich, Germany
[9] Klin Pk, Dept Med Radiat Phys, Zurich, Switzerland
关键词
quality assurance; stereotactic radiosurgery; sterotactic radiotherapy; system test; DIN; 6875-1;
D O I
10.1159/000083175
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The new DIN (' Deutsche Industrie- Norm') 6875- 1, which is currently being finalised, deals with quality assurance ( QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/ radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4- mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in- house, the use of commercially available tools facilitated the QA according to the DIN 6875- 1 with which our results complied. Copyright (C) 2004 S. Karger AG, Basel.
引用
收藏
页码:235 / 243
页数:9
相关论文
共 16 条
[1]  
*DIN, 2003, 68751 DIN
[2]   Quality assurance for the Leksell gamma unit: Considering magnetic resonance image-distortion and delineation failure in the targeting of the internal auditory canal [J].
Ertl, A ;
Saringer, W ;
Heimberger, K ;
Kindl, P .
MEDICAL PHYSICS, 1999, 26 (02) :166-170
[3]   Experimentally determined three-dimensional dose distributions in small complex targets [J].
Mack, A ;
Wolff, R ;
Weltz, D ;
Mack, G ;
Jess, A ;
Heck, B ;
Czempiel, H ;
Kreiner, HJ ;
Wowra, B ;
Böttcher, H ;
Seiffert, V .
JOURNAL OF NEUROSURGERY, 2002, 97 :551-555
[4]   Quality assurance in stereotactic space.: Determination of the accuracy of aim and dose in single dose radiosurgery [J].
Mack, A ;
Mack, G ;
Hönes, A ;
Jess, A ;
Wowra, B ;
Czempiel, H ;
Heck, B ;
Kreiner, HJ ;
Seifert, V ;
Böttcher, H .
STRAHLENTHERAPIE UND ONKOLOGIE, 2003, 179 (11) :760-766
[5]   High precision film dosimetry with GAFCHROMIC® films for quality assurance especially when using small fields [J].
Mack, A ;
Mack, G ;
Weltz, D ;
Scheib, SG ;
Böttcher, HD ;
Seifert, V .
MEDICAL PHYSICS, 2003, 30 (09) :2399-2409
[6]   Verification of dose plans using film dosimetry for quality assurance in radiosurgery [J].
Mack, A ;
Mack, G ;
Weltz, D ;
Czempiel, H ;
Kreiner, HJ .
RADIOSURGERY, VOL 4, 2002, 4 :213-227
[7]   Quality assurance in stereotactic space.: A system test for verifying the accuracy of aim in radiosurgery [J].
Mack, A ;
Czempiel, H ;
Kreiner, HJ ;
Dürr, G ;
Wowra, B .
MEDICAL PHYSICS, 2002, 29 (04) :561-568
[8]   Precision dosimetry for narrow photon beams used in radiosurgery -: Determination of Gamma Knife® output factors [J].
Mack, A ;
Scheib, SG ;
Major, J ;
Gianolini, S ;
Pazmandi, G ;
Feist, H ;
Czempiel, H ;
Kreiner, HJ .
MEDICAL PHYSICS, 2002, 29 (09) :2080-2089
[9]   Analytic characterization of linear accelerator radiosurgery dose distributions for fast optimization [J].
Meeks, SL ;
Bova, FJ ;
Buatti, JM ;
Friedman, WA ;
Eyster, B ;
Kendrick, LA .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (11) :2777-2787
[10]   The use of radiographic firm for linear accelerator stereotactic radiosurgical dosimetry [J].
Robar, JL ;
Clark, BG .
MEDICAL PHYSICS, 1999, 26 (10) :2144-2150