Canadian Field Soils III. Thermal-Conductivity Data and Modeling

被引:99
作者
Tarnawski, V. R. [1 ]
Momose, T. [2 ]
McCombie, M. L. [1 ]
Leong, W. H. [3 ]
机构
[1] St Marys Univ, Div Engn, Halifax, NS B3H 3C3, Canada
[2] Ishikawa Prefectural Univ, Nonoichi, Ishikawa 9218836, Japan
[3] Ryerson Univ, Dept Mech & Ind Engn, Toronto, ON M5B 2K3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Canadian soils; Mineral composition; Quartz; Series-parallel model; Thermal conductivity; Thermal probe; WATER-CONTENT; TEMPERATURE; DIFFUSIVITY;
D O I
10.1007/s10765-014-1793-z
中图分类号
O414.1 [热力学];
学科分类号
摘要
Forty field soil samples, from nine Canadian Provinces, were laboratory tested for their ability to conduct heat, i.e., thermal conductivity (), using a non-stationary probe technique. The measurements were carried out on moderately compacted samples at room temperature, and over a full range of degree of saturation ( ranging from dryness to full saturation. The analysis of data revealed a strong nonlinear variation of versus that can be sub-analyzed in four -based domains, i.e., residual, transitory meniscus, micro/macro-porous capillary, and superfluous. In the residual domain (, a very small variation is observed. In the transitory meniscus domain (, for the majority of soils, a sharp increase was observed. In the micro/macro-porous capillary domain (, a moderate increase was noted. Finally, in the superfluous domain (, a very slight increase was generally noted. On average, the highest values (from 1.9 to 3.2 were obtained from saturated soil samples with high quartz content, e.g., samples from sites in Nova Scotia and Prince Edward Island. On the other hand, the lowest (from 1.1 to 1.4 was observed from saturated soil samples with lower quartz content, e.g., British Columbia samples. The measured data were used to verify a recently developed series-parallel (S-) model for unsaturated soils. On average, estimates of the S- model, with a parallel arrangement of air and water in the third of three conductive paths, were within of experimental data. However, the S- model, with a series arrangement of air and water in the third conductive path, showed slightly better estimates when it was applied to fine-textured soils. In addition, there was no strong correlation noted between the performance of the S- models and soil quartz content. Consequently, it is recommended to compare estimates from both models when they are applied to experimental data.
引用
收藏
页码:119 / 156
页数:38
相关论文
共 39 条
[1]  
Al Nakshabandi G., 1965, Agric. Met., V2, P271
[2]  
[Anonymous], 1995, GUID EXPR UNC MEAS
[3]  
[Anonymous], 1949, BULLETIN
[4]   Comparison of the thermal properties of four wettable and four water-repellent soils [J].
Bachmann, J ;
Horton, R ;
Ren, T ;
van der Ploeg, RR .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2001, 65 (06) :1675-1679
[5]  
Blake BR., 1986, AGRON MONOGR, V9, P377
[6]   MINERALOGY, POROSITY AND FLUID CONTROL ON THERMAL-CONDUCTIVITY OF SEDIMENTARY-ROCKS [J].
BRIGAUD, F ;
VASSEUR, G .
GEOPHYSICAL JOURNAL INTERNATIONAL, 1989, 98 (03) :525-542
[7]   MEASUREMENT OF SOIL THERMAL-PROPERTIES WITH A DUAL-PROBE HEAT-PULSE TECHNIQUE [J].
BRISTOW, KL ;
KLUITENBERG, GJ ;
HORTON, R .
SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1994, 58 (05) :1288-1294
[8]  
Campbell G. S., 1985, Soil physics with BASIC. Transport models for soil-plant systems.
[9]   PREDICTING THE EFFECT OF TEMPERATURE ON SOIL THERMAL-CONDUCTIVITY [J].
CAMPBELL, GS ;
JUNGBAUER, JD ;
BIDLAKE, WR ;
HUNGERFORD, RD .
SOIL SCIENCE, 1994, 158 (05) :307-313
[10]  
CLAPP RB, 1978, WATER RESOUR RES, V14, P601, DOI 10.1029/WR014i004p00601