The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis

被引:148
|
作者
Fluegge, Tabea [1 ,2 ]
van der Meer, Wicher Joerd [3 ,4 ]
Gonzalez, Beatriz Gimenez [2 ]
Vach, Kirstin [5 ]
Wismeijer, Daniel [2 ]
Wang, Ping [6 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg, Freiburg, Germany
[2] ACTA, Dept Oral Implantol, Amsterdam, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, Groningen, Netherlands
[4] WJ Kolff Inst Biomed Engn & Mat Sci, Groningen, Netherlands
[5] Univ Freiburg, Inst Med Biometry & Stat, Fac Med, Freiburg, Germany
[6] Temple Univ, Maurice H Kornberg Sch Dent, Philadelphia, PA 19122 USA
关键词
computer-aided design; digital implant impressions; implant impressions; intraoral scanning; 3-DIMENSIONAL ACCURACY; DIMENSIONAL ACCURACY; EDENTULOUS PATIENTS; MULTIPLE IMPLANTS; VULTIPLE IMPLANTS; ANGULATION; CASTS; FIT; TECHNOLOGY; PRECISION;
D O I
10.1111/clr.13273
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This systematic review and meta-analysis were conducted to assess and compare the accuracy of conventional and digital implant impressions. The review was registered on the PROSPERO register (registration number: CRD42016050730). Material and Methods: A systematic literature search was conducted adhering to PRISMA guidelines to identify studies on implant impressions published between 2012 and 2017. Experimental and clinical studies at all levels of evidence published in peer-reviewed journals were included, excluding expert opinions. Data extraction was performed along defined parameters for studied specimens, digital and conventional impression specifications and outcome assessment. Results: Seventy-nine studies were included for the systematic review, thereof 77 experimental studies, one RCT and one retrospective study. The study setting was in vitro for most of the included studies (75 studies) and in vivo for four studies. Accuracy of conventional impressions was examined in 59 studies, whereas digital impressions were examined in 11 studies. Nine studies compared the accuracy of conventional and digital implant impressions. Reported measurements for the accuracy include the following: (a) linear and angular deviations between reference models and test models fabricated with each impression technique; (b) three-dimensional deviations between impression posts and scan bodies respectively; and (c) fit of implant-supported frameworks, assessed by measuring marginal discrepancy along implant abutments.) Meta-analysis was performed of 62 studies. The results of conventional and digital implant impressions exhibited high values for heterogeneity. Conclusions: The available data for accuracy of digital and conventional implant impressions have a low evidence level and do not include sufficient data on in vivo application to derive clinical recommendations.
引用
收藏
页码:374 / 392
页数:19
相关论文
共 50 条
  • [41] Clinical Effects of Interproximal Contact Loss between Teeth and Implant-Supported Prostheses: Systematic Review and Meta-Analysis
    Nery, James Carlos
    Manarte-Monteiro, Patricia
    Aragao, Leonardo
    da Silva, Ligia Pereira
    Pinto Brandao, Gabriel Silveira
    Lemos, Bernardo Ferreira
    PROSTHESIS, 2024, 6 (04): : 825 - 840
  • [42] EVALUATION OF THE SURVIVAL RATE OF FULL-ARCH IMPLANT-SUPPORTED FIXED PROSTHESES: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Fathi, Amirhossein
    Hashemi, Sara
    Tabatabaei, Shivasadat
    Atash, Ramin
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2023, 15 (03): : 230 - 238
  • [43] Survival analysis of wide dental implant: systematic review and meta-analysis
    Lee, Chun-Teh
    Chen, Ya-Wei
    Starr, Jacqueline R.
    Chuang, Sung-Kiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (10) : 1251 - 1264
  • [44] A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss
    Kern, Jaana-Sophia
    Kern, Thomas
    Wolfart, Stefan
    Heussen, Nicole
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (02) : 174 - 195
  • [45] Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses
    Gomez-Polo, Miguel
    Ballesteros, Juan
    Perales-Padilla, Pedro
    Perales-Pulido, Pedro
    Gomez-Polo, Cristina
    Ortega, Rocio
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02): : 135 - 139
  • [46] Accuracy of the Different Materials Used to Fabricate a Verification Jig of Implant-Supported Fixed Complete Dental Prostheses: An In Vitro Study
    Aljohani, Mawaddah S.
    Bukhari, Heba A.
    Alshehri, Mayar
    Alamoudi, Ahmed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [47] Accuracy of Machine Learning in Identification of Dental Implant Systems in Radiographs - A Systematic Review and Meta-analysis
    Benakatti, Veena
    Nayakar, Ramesh P.
    Anandhalli, Mallikarjun
    Lagali-Jirge, Vasanti
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (03) : 354 - 358
  • [48] TECHNOLOGICAL PARTICULARITIES OF THE IMPLANT-SUPPORTED DENTAL PROSTHESES. CASE REPORT
    Diaconu-Popa, Diana
    Tatarciuc, Monica
    Vitalariu, Anca
    Luca, Odette
    MEDICAL-SURGICAL JOURNAL-REVISTA MEDICO-CHIRURGICALA, 2019, 123 (03): : 547 - 551
  • [49] Static and Fatigue Loading of Veneered Implant-Supported Fixed Dental Prostheses
    Rayyan, Mohammad M.
    Abdallah, Jihad
    Segaan, Lucette G.
    Bonfante, Estevam A.
    Osman, Essam
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (08): : 679 - 685
  • [50] In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses
    Costa, Vitoria
    Silva, Antonio Sergio
    Costa, Rosana
    Barreiros, Pedro
    Mendes, Joana
    Mendes, Jose Manuel
    DENTISTRY JOURNAL, 2022, 10 (06)