The accuracy of different dental impression techniques for implant-supported dental prostheses: A systematic review and meta-analysis

被引:148
作者
Fluegge, Tabea [1 ,2 ]
van der Meer, Wicher Joerd [3 ,4 ]
Gonzalez, Beatriz Gimenez [2 ]
Vach, Kirstin [5 ]
Wismeijer, Daniel [2 ]
Wang, Ping [6 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg, Freiburg, Germany
[2] ACTA, Dept Oral Implantol, Amsterdam, Netherlands
[3] Univ Groningen, Univ Med Ctr Groningen, Dept Orthodont, Groningen, Netherlands
[4] WJ Kolff Inst Biomed Engn & Mat Sci, Groningen, Netherlands
[5] Univ Freiburg, Inst Med Biometry & Stat, Fac Med, Freiburg, Germany
[6] Temple Univ, Maurice H Kornberg Sch Dent, Philadelphia, PA 19122 USA
关键词
computer-aided design; digital implant impressions; implant impressions; intraoral scanning; 3-DIMENSIONAL ACCURACY; DIMENSIONAL ACCURACY; EDENTULOUS PATIENTS; MULTIPLE IMPLANTS; VULTIPLE IMPLANTS; ANGULATION; CASTS; FIT; TECHNOLOGY; PRECISION;
D O I
10.1111/clr.13273
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This systematic review and meta-analysis were conducted to assess and compare the accuracy of conventional and digital implant impressions. The review was registered on the PROSPERO register (registration number: CRD42016050730). Material and Methods: A systematic literature search was conducted adhering to PRISMA guidelines to identify studies on implant impressions published between 2012 and 2017. Experimental and clinical studies at all levels of evidence published in peer-reviewed journals were included, excluding expert opinions. Data extraction was performed along defined parameters for studied specimens, digital and conventional impression specifications and outcome assessment. Results: Seventy-nine studies were included for the systematic review, thereof 77 experimental studies, one RCT and one retrospective study. The study setting was in vitro for most of the included studies (75 studies) and in vivo for four studies. Accuracy of conventional impressions was examined in 59 studies, whereas digital impressions were examined in 11 studies. Nine studies compared the accuracy of conventional and digital implant impressions. Reported measurements for the accuracy include the following: (a) linear and angular deviations between reference models and test models fabricated with each impression technique; (b) three-dimensional deviations between impression posts and scan bodies respectively; and (c) fit of implant-supported frameworks, assessed by measuring marginal discrepancy along implant abutments.) Meta-analysis was performed of 62 studies. The results of conventional and digital implant impressions exhibited high values for heterogeneity. Conclusions: The available data for accuracy of digital and conventional implant impressions have a low evidence level and do not include sufficient data on in vivo application to derive clinical recommendations.
引用
收藏
页码:374 / 392
页数:19
相关论文
共 96 条
  • [1] The Influence of Digital Fabrication Options on the Accuracy of Dental Implant-Based Single Units and Complete-Arch Frameworks
    Abdel-Azim, Tamer
    Zandinejad, Amirali
    Elathamna, Eiad
    Lin, Weishao
    Morton, Dean
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : 1281 - 1288
  • [2] Effects of Implant Angulation, Impression Material, and Variation in Arch Curvature Width on Implant Transfer Model Accuracy
    Akalin, Zerrin Fidan
    Ozkan, Yasemin Kulak
    Ekerim, Ahmet
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 149 - 157
  • [3] EFFECT OF DIGITIZING TECHNIQUES ON THE FIT OF IMPLANT-RETAINED CROWNS WITH DIFFERENT ANTI ROTATIONAL ABUTMENT FEATURES
    Aktas, Guliz
    Ozcan, Nihal
    Aydin, Didem Hasanoglu
    Sahin, Erdal
    Akca, Kivanc
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (05) : 367 - 372
  • [4] Al Quran FA, 2012, QUINTESSENCE INT, V43, P119
  • [5] AN IN VITRO COMPARISON OF THE ACCURACY OF IMPLANT IMPRESSIONS WITH CODED HEALING ABUTMENTS AND DIFFERENT IMPLANT ANGULATIONS
    Al-Abdullah, Khaled
    Zandparsa, Roya
    Finkelman, Matthew
    Hirayama, Hiroshi
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (02) : 90 - 100
  • [6] Accuracy of Interchangeable Implant Impression Systems: An In Vitro Pilot Study
    Aldosari, Abdullah M. AlFarraj
    AlBaker, Abdulaziz M.
    AlShihri, Abdulmonem A.
    AlJadeed, Majid I.
    AlBwardi, Loay A.
    Anil, Sukumaran
    [J]. IMPLANT DENTISTRY, 2015, 24 (03) : 317 - 322
  • [7] Does Steam Autoclaving Affect the Accuracy of Implant Impression Systems?
    Aldosari, Abdullah M. AlFarraj
    [J]. JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2014, 4 (07) : 550 - 554
  • [8] Alikhasi Marzieh, 2015, J Dent (Tehran), V12, P774
  • [9] The Effect of Implant Angulation on the Transfer Accuracy of External-Connection Implants
    Alikhasi, Marzieh
    Siadat, Hakimeh
    Rahimian, Susan
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 822 - 829
  • [10] Effect of Multiple Use of Impression Copings on the Accuracy of Implant Transfer
    Alikhasi, Marzieh
    Bassir, Seyed Hossein
    Naini, Roshanak Baghai
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 408 - 414