A software package for non-invasive, real-time beat-to-beat monitoring of stroke volume, blood pressure, total peripheral resistance and for assessment of autonomic function

被引:120
|
作者
Gratze, G
Fortin, J
Holler, A
Grasenick, K
Pfurtscheller, G
Wach, P
Schonegger, J
Kotanko, P
Skrabal, F
机构
[1] Graz Univ, Dept Internal Med, Teaching Hosp, Krankenhaus Barmherzigen Bruder, A-8020 Graz, Austria
[2] Graz Univ Technol, Inst Electro & Biomed, A-8010 Graz, Austria
基金
奥地利科学基金会;
关键词
non-invasive beat-to-beat recording; stroke volume; peripheral resistance; impedance cardiography; autonomic nervous system; baroreceptor reflex;
D O I
10.1016/S0010-4825(98)00005-5
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The goal of the present study was to develop and evaluate algorithms for non-invasive, real-time, beat-to-beat monitoring of stroke index (SI), blood pressure (BP) and total peripheral resistance index (TPRI) which has a menu-driven interface, suitable for routine use by unskilled staff. In addition, it was our aim to include a mete-analysis for the evaluation of autonomic function derived from the above haemodynamic data. This includes spectral analysis of heart rate (HR), BP, SI and TPRI and the automatic calculation of baroreceptor reflex sensitivity. Impedance cardiography was used for beat-to-beat SI determination, Finapres(TM) corrected by an oscillometric blood pressure measurement (Dinamap(R)) on the upper arm for beat-to-beat BP measurement. We demonstrate noise free recordings during physiological (head up tilt) and pharmacological intervention (alpha(1)-, beta(2)-adrenoreceptor agonists, insulin induced hypoglycemia). The newly developed software should prove valuable for physiological, pharmacological and clinical studies. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:121 / 142
页数:22
相关论文
共 46 条
  • [1] Non-invasive beat-to-beat blood pressure monitoring: new developments
    Parati, G
    Ongaro, G
    Bilo, G
    Glavina, F
    Castiglioni, P
    Di Rienzo, M
    Mancia, G
    BLOOD PRESSURE MONITORING, 2003, 8 (01) : 31 - 36
  • [2] Development and clinical validation of a non-invasive, beat-to-beat blood pressure monitoring device, compared to invasive blood pressure monitoring during coronary angiography
    Borges, Melanie Aparecida
    Prado, Marcelo
    de Souza Santini, Tales Roberto
    Pereira Barbosa, Adriano Henrique
    Moreira, Antonio Carlos
    Ishibe, Eder Issao
    Katz, Marcelo
    Cintra, Fatima Dumas
    EINSTEIN-SAO PAULO, 2019, 17 (02): : eAO4156
  • [3] Application of Nexfin noninvasive beat-to-beat arterial blood pressure monitoring in autonomic function testing
    Sipkens, Laura M.
    Treskes, Kaij
    Ariese-Beldman, Karin
    Veerman, Derk P.
    Boer, Christa
    BLOOD PRESSURE MONITORING, 2011, 16 (05) : 246 - 251
  • [4] Pulse Spectroscopy System for Non-Invasive Real-Time Monitoring of the Heart Beat Volume
    Andruschenko, S.
    Timm, U.
    Hinz, M.
    Koball, S.
    Kraitl, J.
    Lewis, E.
    Ewald, H.
    2010 IEEE SENSORS, 2010, : 1863 - 1868
  • [5] THE ASSESSMENT OF AUTONOMIC FUNCTION FROM THE BEAT-TO-BEAT BLOOD-PRESSURE RESPONSE TO A VALSALVA MANEUVER
    FREEMAN, R
    HARRY, J
    BROADBRIDGE, C
    NEUROLOGY, 1994, 44 (04) : A221 - A221
  • [6] NON-INVASIVE BEAT-TO-BEAT MEASUREMENT OF HEMODYINAMIC PARAMETERS IN THE ASSESSMENT OF AUTONOMIC DYSFUNCTIONS IN PATIENTS WITH PORTAL HYPERTENSION
    Finkenstedt, Armin
    Graziadei, Ivo W.
    Nachbaur, Karin
    Vogel, Wolfgang
    HEPATOLOGY, 2008, 48 (04) : 1053A - 1053A
  • [7] A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring
    Ciarán Finucane
    V. K. van Wijnen
    C. W. Fan
    C. Soraghan
    L. Byrne
    B. E. Westerhof
    R. Freeman
    A. Fedorowski
    M. P. M. Harms
    W. Wieling
    R. Kenny
    Clinical Autonomic Research, 2019, 29 : 427 - 441
  • [8] A practical guide to active stand testing and analysis using continuous beat-to-beat non-invasive blood pressure monitoring
    Finucane, Ciaran
    van Wijnen, V. K.
    Fan, C. W.
    Soraghan, C.
    Byrne, L.
    Westerhof, B. E.
    Freeman, R.
    Fedorowski, A.
    Harms, M. P. M.
    Wieling, W.
    Kenny, R.
    CLINICAL AUTONOMIC RESEARCH, 2019, 29 (04) : 427 - 441
  • [9] A Wireless Wearable Sensor Patch for the Real-Time Estimation of Continuous Beat-to-Beat Blood Pressure
    Qiu, Chunkai
    Wu, Taiyang
    Redoute, Jean-Michel
    Yuce, Mehmet Rasit
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6842 - 6845
  • [10] Novel Metric for Non-Invasive Beat-to-Beat Blood Pressure Measurements Demonstrates Physiological Blood Pressure Fluctuations during Pregnancy
    Zimmermann, David
    Malberg, Hagen
    Schmidt, Martin
    SENSORS, 2024, 24 (10)