Asymmetric flow field-flow fractionation (AF4) with fluorescence and multi-detector analysis for direct, real-time, size-resolved measurements of drug release from polymeric nanoparticles

被引:15
作者
Shakiba, Sheyda [1 ]
Astete, Carlos E. [2 ]
Cueto, Rafael [3 ]
Rodrigues, Debora F. [1 ]
Sabliov, Cristina M. [2 ]
Louie, Stacey M. [1 ]
机构
[1] Univ Houston, Dept Civil & Environm Engn, Houston, TX 77004 USA
[2] Louisiana State Univ, Dept Biol & Agr Engn, Baton Rouge, LA 70803 USA
[3] Louisiana State Univ, Dept Chem, Baton Rouge, LA 70803 USA
关键词
Polymeric nanoparticles; Release profile; Method development; Asymmetric flow field-flow fractionation; Fluorescent drug; Dialysis; MULTIANGLE LIGHT-SCATTERING; NATURAL COLLOIDS; ONLINE DETECTION; DELIVERY; PLGA; MACROMOLECULES; CHROMATOGRAPHY; NANOCARRIERS; ENHANCEMENT; SEPARATION;
D O I
10.1016/j.jconrel.2021.08.041
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Polymeric nanoparticles (NPs) are typically designed to enhance the efficiency of drug delivery by controlling the drug release rate. Hence, it is critical to obtain an accurate drug release profile. This study presents the first application of asymmetric flow field-flow fractionation (AF4) with fluorescence detection (FLD) to quantify release profiles of fluorescent drugs from polymeric NPs, specifically poly(lactic-co-glycolic acid) NPs loaded with enrofloxacin (PLGA-Enro NPs). In contrast to conventional measurements requiring separation of the NPs and dissolved drugs (typically by dialysis) prior to quantification, AF4 provides in situ removal of unincorporated drugs, while the judicious combination of online FLD and UV detection selectively provides the entrapped drug and PLGA NP concentrations, respectively, and hence the drug loading. NP size and shape factors are simultaneously obtained by online dynamic and multi-angle light scattering (DLS, MALS) detectors. The AF4 and dialysis approaches were compared to evaluate drug release from PLGA-Enro NPs containing a high proportion (approximate to 94%) of unincorporated (burst release) drug at three temperatures spanning the glass transition temperature (Tg approximate to 33 degrees C) of the NPs. The AF4 method clearly captured the temperature dependence of the drug release relative to Tg (from no release at 20 degrees C to rapid release at 37 degrees C). In contrast, dialysis was not able to distinguish differences in the extent or rate of release of the entrapped drug because of interferences from the burst release, as well as the dialysis lag time, as supported through a diffusion model and validation experiments on purified NPs with low burst release. Finally, the multi-detector AF4 analysis yielded unique size-dependent release profiles across the entire NP size distribution, with smaller NPs showing faster release consistent with radial diffusion from the NPs. Overall, this study demonstrates the novel application and advantages of multi-detector AF4 methods, particularly AF4-FLD, to obtain direct, size-resolved release profiles of fluorescent drugs from polymeric NPs.
引用
收藏
页码:410 / 421
页数:12
相关论文
共 80 条
[1]   Comparison of molecular and emulsifying properties of gum arabic and mesquite gum using asymmetrical flow field-flow fractionation [J].
Alftren, Johan ;
Penarrieta, J. Mauricio ;
Bergenstahl, Bjorn ;
Nilsson, Lars .
FOOD HYDROCOLLOIDS, 2012, 26 (01) :54-62
[2]   Characterization of doxorubicin liposomal formulations for size-based distribution of drug and excipients using asymmetric-flow field-flow fractionation (AF4) and liquid chromatography-mass spectrometry (LC-MS) [J].
Ansar, Siyam M. ;
Mudalige, Thilak .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2020, 574
[3]   Nanoparticles in the clinic: An update [J].
Anselmo, Aaron C. ;
Mitragotri, Samir .
BIOENGINEERING & TRANSLATIONAL MEDICINE, 2019, 4 (03)
[4]   Synthesis and characterization of PLGA nanoparticles [J].
Astete, Carlos E. ;
Sabliov, Cristina M. .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2006, 17 (03) :247-289
[5]   Flow field-flow fractionation for the analysis and characterization of natural colloids and manufactured nanoparticles in environmental systems: A critical review [J].
Baalousha, M. ;
Stolpe, B. ;
Lead, J. R. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (27) :4078-4103
[6]   Coupling single particle ICP-MS with field-flow fractionation for characterizing metal nanoparticles contained in nanoplastic colloids [J].
Barber, Angela ;
Kly, Sun ;
Moffitt, Matthew G. ;
Rand, Logan ;
Ranville, James F. .
ENVIRONMENTAL SCIENCE-NANO, 2020, 7 (02) :514-524
[7]   Comparison of SEC and AF4 analytical tools for size estimation of typhoid Vi polysaccharides [J].
Bayart, Caroline ;
Jean, Elisa ;
Paillagot, Marie ;
Renoud, Alexia ;
Raillard, Alice ;
Paladino, Joseph ;
Le Borgne, Marc .
ANALYTICAL METHODS, 2019, 11 (37) :4851-4858
[8]   Application of asymmetric flow field-flow fractionation (AsFlFFF) coupled to inductively coupled plasma mass spectrometry (ICPMS) to the quantitative characterization of natural colloids and synthetic nanoparticles [J].
Bouby, M. ;
Geckeis, H. ;
Geyer, F. W. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (7-8) :1447-1457
[9]   INFORMATION ON POLYDISPERSITY AND BRANCHING FROM COMBINED QUASI-ELASTIC AND INTEGRATED SCATTERING [J].
BURCHARD, W ;
SCHMIDT, M ;
STOCKMAYER, WH .
MACROMOLECULES, 1980, 13 (05) :1265-1272
[10]   Asymmetric-flow field-flow fractionation for measuring particle size, drug loading and (in)stability of nanopharmaceuticals. The joint view of European Union Nanomedicine Characterization Laboratory and National Cancer Institute - Nanotechnology Characterization Laboratory [J].
Caputo, F. ;
Mehn, D. ;
Clogston, J. D. ;
Roesslein, M. ;
Prina-Mello, A. ;
Borgos, S. E. ;
Gioria, S. ;
Calzolai, L. .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1635