System Maps for Retention of Small Neutral Compounds on a Superficially Porous Ethyl-Bridged, Octadecylsiloxane-Bonded Silica Stationary Phase in Reversed-Phase Liquid Chromatography

被引:11
作者
Atapattu, Sanka N. [1 ]
Poole, Colin F. [2 ]
Praseuth, Mike B. [3 ]
机构
[1] CanAm Biores Inc, Winnipeg, MB R3T 0P4, Canada
[2] Wayne State Univ, Dept Chem, Detroit, MI 48202 USA
[3] Phenomenex Inc, Torrance, CA 90501 USA
关键词
Reversed-phase liquid chromatography; Retention; Selectivity; Solvation parameter model; System maps; Retention mapping; Superficially porous particles; BASIC COMPOUNDS; COLUMN; MODEL;
D O I
10.1007/s10337-017-3350-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The system constants of the solvation parameter model are used to prepare system maps for the retention of small neutral compounds on an ethyl-bridged, ocatadecylsiloxane-bonded superficially porous silica stationary phase (Kinetex EVO C18) for aqueous mobile phases containing 10-70% (v/v) methanol or acetonitrile. Electrostatic interactions (cation-exchange) are important for the retention of weak bases with acetonitrile-water but not methanol-water mobile phase compositions. Compared with a superficially porous octadecylsiloxane-bonded silica stationary phase (Kinetex C18) with a similar morphology but different topology statistically significant differences in selectivity at the 95% confidence level are observed for neutral compounds that vary by size and hydrogen-bond basicity with other intermolecular interactions roughly similar. These selectivity differences are dampened with acetonitrile-water mobile phases, but are significant for methanol-water mobile phase compositions containing < 30% (v/v) methanol. A comparison of a totally porous ethyl-bridged, octadecylsiloxane-bonded silica stationary phase (XBridge C18) with Kinetex EVO C18 indicated that they are effectively selectivity equivalent.
引用
收藏
页码:1279 / 1286
页数:8
相关论文
共 50 条
[41]   Retention models for ionizable compounds in reversed-phase liquid chromatography Effect of variation of mobile phase composition and temperature [J].
Roses, Marti ;
Subirats, Xavier ;
Bosch, Elisabeth .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (10) :1756-1775
[42]   Poly(1-allylimidazole)-grafted silica, a new specific stationary phase for reversed-phase and anion-exchange liquid chromatography [J].
Sun, Min ;
Qiu, Hongdeng ;
Wang, Licheng ;
Liu, Xia ;
Jiang, Shengxiang .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (18) :3904-3909
[43]   Uncertainty management for In Silico screening of reversed-phase liquid chromatography methods for small compounds [J].
Van Laethem, Thomas ;
Kumari, Priyanka ;
Boulanger, Bruno ;
Hubert, Philippe ;
Fillet, Marianne ;
Sacre, Pierre-Yves ;
Hubert, Cedric .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 249
[44]   Retention of polycyclic aromatic hydrocarbons on propyl-phenyl stationary phases in reversed-phase high performance liquid chromatography [J].
Kayillo, Sindy ;
Dennis, Gary R. ;
Shalliker, R. Andrew .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) :168-176
[45]   Synthesis and characterization of novel polar-embedded silica stationary phases for use in reversed-phase high-performance liquid chromatography [J].
Wang, Haibo ;
Chen, Lei ;
Tang, Xiuling ;
Jia, Yanyan ;
Li, Guangqing ;
Sun, Xiaoli ;
Wen, Aidong .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1271 :153-162
[46]   Dicationic imidazolium ionic liquid modified silica as a novel reversed-phase/anion-exchange mixed-mode stationary phase for high-performance liquid chromatography [J].
Sun, Min ;
Feng, Juanjuan ;
Wang, Xiaojiao ;
Duan, Huimin ;
Li, Leilei ;
Luo, Chuannan .
JOURNAL OF SEPARATION SCIENCE, 2014, 37 (16) :2153-2159
[47]   Prediction of the octanol-water partition constant of neutral compounds by reversed-phase liquid chromatography using alternative organic solvent modifiers [J].
Atapattu, Sanka N. ;
Poole, Colin F. .
JOURNAL OF CHROMATOGRAPHY A, 2025, 1741
[48]   Quantitative structure-retention relationships in reversed-phase liquid chromatography using several stationary and mobile phases [J].
Vonk, EC ;
Lewandowska, K ;
Claessens, HA ;
Kaliszan, R ;
Cramers, CA .
JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) :777-792
[49]   Solvation parameter models for retention on perfluorinated and fluorinated low temperature glassy carbon stationary phases in reversed-phase liquid chromatography [J].
Shearer, Justin W. ;
Ding, Lunhan ;
Olesik, Susan V. .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (01) :73-80
[50]   INFLUENCE OF SOLVENT EFFECTS ON RETENTION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY AND SOLID-PHASE EXTRACTION USING A CYANOPROPYLSILOXANE-BONDED, SILICA-BASED SORBENT [J].
SEIBERT, DS ;
POOLE, CF .
CHROMATOGRAPHIA, 1995, 41 (1-2) :51-60