Dose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size

被引:34
作者
Huang, Baotian [1 ]
Wu, Lili [1 ]
Lin, Peixian [2 ]
Chen, Chuangzhen [1 ]
机构
[1] Shantou Univ, Coll Med, Canc Hosp, Dept Radiat Oncol, Shantou 515031, Peoples R China
[2] Shantou Univ, Coll Med, Affiliated Hosp 2, Dept Nosocomial Infect Management, Shantou 515041, Peoples R China
来源
RADIATION ONCOLOGY | 2015年 / 10卷
关键词
Dose difference; Acuros XB; Anisotropic analytical algorithm; Stereotactic body radiotherapy; Calculation grid size; RADIATION-THERAPY; DOSIMETRIC IMPACT; NASOPHARYNGEAL CARCINOMA; HETEROGENEOUS MEDIA; MONTE-CARLO; VALIDATION; VERIFICATION; ACCURACY; PLANS; WATER;
D O I
10.1186/s13014-015-0357-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The study aimed to appraise the dose differences between Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) in stereotactic body radiotherapy (SBRT) treatment for lung cancer with flattening filter free (FFF) beams. Additionally, the potential role of the calculation grid size (CGS) on the dose differences between the two algorithms was also investigated. Methods: SBRT plans with 6X and 10X FFF beams produced from the CT scan data of 10 patients suffering from stage I lung cancer were enrolled in this study. Clinically acceptable treatment plans with AAA were recalculated using AXB with the same monitor units (MU) and identical multileaf collimator (MLC) settings. Furthermore, different CGS (2.5 mm and 1 mm) in the two algorithms was also employed to investigate their dosimetric impact. Dose to planning target volumes (PTV) and organs at risk (OARs) between the two algorithms were compared. PTV was separated into PTV_soft (density in soft-tissue range) and PTV_lung (density in lung range) for comparison. Results: The dose to PTV_lung predicted by AXB was found to be 1.33 +/- 1.12% (6XFFF beam with 2.5 mm CGS), 2.33 +/- 1.37% (6XFFF beam with 1 mm CGS), 2.81 +/- 2.33% (10XFFF beam with 2.5 mm CGS) and 3.34 +/- 1.76% (10XFFF beam with 1 mm CGS) lower compared with that by AAA, respectively. However, the dose directed to PTV_soft was comparable. For OARs, AXB predicted a slightly lower dose to the aorta, chest wall, spinal cord and esophagus, regardless of whether the 6XFFF or 10XFFF beam was utilized. Exceptionally, dose to the ipsilateral lung was significantly higher with AXB. Conclusions: AXB principally predicts lower dose to PTV_lung compared to AAA and the CGS contributes to the relative dose difference between the two algorithms.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] American Asociation of Physicists in Medicine, 2004, TISS INH CORR MEG PH
  • [2] Clinical and Dosimetric Predictors of Radiation Pneumonitis in a Large Series of Patients Treated With Stereotactic Body Radiation Therapy to the Lung
    Baker, Ryan
    Han, Gang
    Sarangkasiri, Siriporn
    DeMarco, MaryLou
    Turke, Carolyn
    Stevens, Craig W.
    Dilling, Thomas J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (01): : 190 - 195
  • [3] Dosimetric validation of Acuros® XB with Monte Carlo methods for photon dose calculations
    Bush, K.
    Gagne, I. M.
    Zavgorodni, S.
    Ansbacher, W.
    Beckham, W.
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2208 - 2221
  • [4] Dose variations with varying calculation grid size in head and neck IMRT
    Chung, Heeteak
    Jin, Hosang
    Palta, Jatinder
    Suh, Tae-Suk
    Kim, Siyong
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (19) : 4841 - 4856
  • [5] Determination of patient-specific internal gross tumor volumes for lung cancer using four-dimensional computed tomography
    Ezhil, Muthuveni
    Vedam, Sastry
    Balter, Peter
    Choi, Bum
    Mirkovic, Dragan
    Starkschall, George
    Chang, Joe Y.
    [J]. RADIATION ONCOLOGY, 2009, 4
  • [6] Critical Appraisal of Acuros XB and Anisotropic Analytic Algorithm Dose Calculation in Advanced Non-Small-Cell Lung Cancer Treatments
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (05): : 1587 - 1595
  • [7] On the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [8] Dosimetric evaluation of Acuros XB Advanced Dose Calculation algorithm in heterogeneous media
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [9] Dosimetric validation of the Acuros XB Advanced Dose Calculation algorithm: fundamental characterization in water
    Fogliata, Antonella
    Nicolini, Giorgia
    Clivio, Alessandro
    Vanetti, Eugenio
    Mancosu, Pietro
    Cozzi, Luca
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) : 1879 - 1904
  • [10] Dosimetric impact of Acuros XB deterministic radiation transport algorithm for heterogeneous dose calculation in lung cancer
    Han, Tao
    Followill, David
    Mikell, Justin
    Repchak, Roman
    Molineu, Andrea
    Howell, Rebecca
    Salehpour, Mohammad
    Mourtada, Firas
    [J]. MEDICAL PHYSICS, 2013, 40 (05)