Fast Neutron Detection With 4H-SiC Based Diode Detector up to 500°C Ambient Temperature

被引:34
|
作者
Szalkai, D. [1 ]
Ferone, R. [2 ]
Issa, F. [2 ]
Klix, A. [1 ]
Lazar, M. [3 ]
Lyoussi, A. [4 ]
Ottaviani, L. [2 ]
Tutto, P. [5 ]
Vervisch, V. [2 ]
机构
[1] Karlsruhe Inst Technol, Inst Neutron Phys & Reactor Technol, D-76344 Eggenstein Leopoldshafen, Germany
[2] Aix Marseille Univ, UMR 7334, IM2NP, CNRS, F-13397 Marseille 20, France
[3] INSA Lyon, UMR 5005, AMPERE, F-69621 Villeurbanne, France
[4] CEA, DEN, DER, Serv Phys Expt,Lab Dosimetrie Capteurs Instrument, F-13108 St Paul Les Durance, France
[5] Semilab Semicond Phys Lab Co Ltd, H-1117 Budapest, Hungary
关键词
Neutron detectors; silicon carbide; 4H;
D O I
10.1109/TNS.2016.2522921
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the framework of the European I-Smart project, optimal 4H-SiC based diode geometries were developed for high temperature neutron detection. Irradiation tests were conducted with 14 MeV fast neutrons supplied by a deuterium-tritium neutron generator with an average neutron yield of 4.04 x 10(10) - 5.25 x 10(10) n/s at Neutron Laboratory of the Technical University of Dresden in Germany. In this paper, we interpret the first measurements and results with 4H-SiC detector irradiated with fast neutrons from room temperature up to 500 degrees C. These experiments are serving also the first simulation of the harsh environmental condition measurements in the tritium breeding blanket of the ITER fusion reactor, which is one of the most prominent planned location of high temperature neutron flux characterization studies in the near future.
引用
收藏
页码:1491 / 1498
页数:8
相关论文
共 50 条
  • [1] Radiation detector based on 4H-SiC used for thermal neutron detection
    Zatko, B.
    Sagatova, A.
    Sedlackova, K.
    Bohacek, P.
    Sekacova, M.
    Kohout, Z.
    Granja, C.
    Necas, V.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [2] Neutron detection using epitaxial 4H-SiC detector structures
    Zat'ko, B.
    Sagatova, A.
    Sedlackova, K.
    Bohacek, P.
    Sekacova, M.
    Kovacova, E.
    Necas, V.
    2018 12TH INTERNATIONAL CONFERENCE ON ADVANCED SEMICONDUCTOR DEVICES AND MICROSYSTEMS (ASDAM), 2018, : 41 - 44
  • [3] Performance of a 4H-SiC Schottky diode as a compact sized detector for neutron pulse form measurements
    Wu, Jian
    Li, Meng
    Jiang, Yong
    Li, Junjie
    Zhang, Yi
    Gao, Hui
    Liu, Xiaobo
    Du, Jinfeng
    Zou, Dehui
    Fan, Xiaoqiang
    Gan, Lei
    Peng, Cheng
    Lu, Yi
    Lei, Jiarong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 771 : 17 - 20
  • [4] High-resolution alpha-particle detector based on Schottky barrier 4H-SiC detector operated at elevated temperatures up to 500 °C
    Gal, Norbert
    Hrubcin, Ladislav
    Sagatova, Andrea
    Vanko, Gabriel
    Kovacova, Eva
    Zatko, Bohumir
    APPLIED SURFACE SCIENCE, 2023, 635
  • [5] γ-ray detector based on n-type 4H-SiC Schottky barrier diode
    Du Yuan-Yuan
    Zhang Chun-Lei
    Cao Xue-Lei
    ACTA PHYSICA SINICA, 2016, 65 (20)
  • [6] Investigation on the charge collection properties of a 4H-SiC Schottky diode detector
    Verzellesi, G
    Vanni, P
    Nava, F
    Canali, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (03) : 717 - 721
  • [7] Performance degradation and defect characterization of Ni/4H-SiC Schottky diode neutron detector in high fluence rate neutron irradiation
    Liu, L. Y.
    Shen, T. L.
    Liu, A.
    Zhang, T.
    Bai, S.
    Xu, S. R.
    Jin, P.
    Hao, Y.
    Ouyang, X. P.
    DIAMOND AND RELATED MATERIALS, 2018, 88 : 256 - 261
  • [8] Study on 4H-SiC Trench Schottky-Type Neutron Detector
    Jiang, Wan-Chen
    Wang, Ying
    Hong, Bing
    Liu, Yun-Tao
    Zhang, Rui
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [9] Temperature sensor based on 4H-SiC diodes for hostile environments Temperature measurement up to T=300°C
    Rao, S.
    Pangallo, G.
    Della Corte, F. G.
    Nipoti, R.
    2015 18TH AISEM ANNUAL CONFERENCE, 2015,
  • [10] 400 °C Sensor Based on Ni/4H-SiC Schottky Diode for Reliable Temperature Monitoring in Industrial Environments
    Draghici, Florin
    Brezeanu, Gheorghe
    Pristavu, Gheorghe
    Pascu, Razvan
    Badila, Marian
    Pribeanu, Adriana
    Ceuca, Emilian
    SENSORS, 2019, 19 (10):