Delayed Ipsilateral Parenchymal Hemorrhage Following Flow Diversion for the Treatment of Anterior Circulation Aneurysms

被引:147
作者
Cruz, J. P. [3 ]
Chow, M. [2 ]
O'Kelly, C. [2 ]
Marotta, B. [4 ]
Spears, J. [1 ,3 ]
Montanera, W. [3 ]
Fiorella, D. [5 ]
Marotta, T. [1 ,3 ]
机构
[1] Univ Toronto, St Michaels Hosp, Dept Surg, Div Neurosurg, Toronto, ON M5B 1W8, Canada
[2] Univ Edmonton, Dept Surg, Div Neurosurg, Edmonton, AB, Canada
[3] Univ Toronto, Dept Med Imaging, Toronto, ON M5B 1W8, Canada
[4] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
[5] SUNY Stony Brook, Med Ctr, Cerebrovasc Ctr, Dept Neurosurg, Stony Brook, NY 11794 USA
基金
美国国家卫生研究院;
关键词
PERCUTANEOUS CORONARY INTERVENTION; INTRACRANIAL ANEURYSMS; CEREBRAL ANEURYSMS; ENDOVASCULAR TREATMENT; EMBOLIZATION; RECONSTRUCTION; METAANALYSIS; CLOPIDOGREL; COMPLICATIONS; EXPERIENCE;
D O I
10.3174/ajnr.A3065
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The PED is a flow-diverting stent designed for the treatment of cerebral aneurysms. We report 4 cases of delayed ipsilateral IPH following the technically successful treatment of anterior circulation aneurysms with the PED. MATERIALS AND METHODS: Clinical and imaging data from all patients undergoing aneurysm treatment with the PED at 2 institutions were analyzed to assess the incidence of delayed IPH after treatment with the PED. RESULTS: A total of 66 patients (47 anterior circulation) with cerebral aneurysms underwent treatment with a PED between January 2008 and November 2010. Four patients experienced delayed periprocedural IPH, all after the treatment of anterior circulation aneurysms (8.5%, 4/47). The aneurysm size ranged from 5 to 21 mm. All IPHs occurred within the cerebral hemisphere, ipsilateral to the treated aneurysm, and were anatomically remote from the treated aneurysms. All procedures were uncomplicated, and patients emerged from general anesthesia at neurologic baseline. The hemorrhages became clinically evident between 1 and 6 days after the procedure. Two patients had unfavorable outcomes (mRS scores, 4 and 6). CONCLUSIONS: Delayed IPH may occur after the treatment of anterior circulation aneurysms with flow diverters. This complication does not seem to be restricted to a specific aneurysm subtype and does not seem to be related to an intraprocedural complication or solely attributable to DAT.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 37 条
[1]   Impact of Platelet Reactivity on Clinical Outcomes After Percutaneous Coronary Intervention A Collaborative Meta-Analysis of Individual Participant Data [J].
Brar, Somjot S. ;
ten Berg, Jurrien ;
Marcucci, Rossella ;
Price, Matthew J. ;
Valgimigli, Marco ;
Kim, Hyo-Soo ;
Patti, Giuseppe ;
Breet, Nicoline J. ;
DiSciascio, Germano ;
Cuisset, Thomas ;
Dangas, George .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (19) :1945-1954
[2]   Frequency of thromboembolic events associated with endovascular aneurysm treatment: retrospective case series [J].
Brooks, Nathaniel P. ;
Turk, Aquilla S. ;
Niemann, David B. ;
Aagaard-Kienitz, Beverly ;
Pulfer, Kari ;
Cook, Thomas .
JOURNAL OF NEUROSURGERY, 2008, 108 (06) :1095-1100
[3]  
Castel JP, 2000, SURG NEUROL, V53, P27
[4]   Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Scrivano, E. ;
Ceratto, R. ;
Lylyk, P. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :27-33
[5]   Clopidogrel (Plavix) [J].
Comin, J. ;
Kallmes, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (11) :2002-2004
[6]   Flow Diversion for Intracranial Aneurysms A Review [J].
D'Urso, Pietro I. ;
Lanzino, Giuseppe ;
Cloft, Harry J. ;
Kallmes, David F. .
STROKE, 2011, 42 (08) :2363-2368
[7]   Aspirin and clopidogrel compared with clopidogrel alone after recent ischaemic stroke or transient ischaemic attack in high-risk patients (MATCH): randomised, double-blind, placebo-controlled trial [J].
Diener, HC ;
Bogousslavsky, J ;
Brass, LM ;
Cimminiello, C ;
Csiba, L ;
Kaste, M ;
Leys, D ;
Matias-Guiv, J ;
Rupprecht, HJ .
LANCET, 2004, 364 (9431) :331-337
[8]   Endografting of the descending thoracic aorta increases ascending aortic input impedance and attenuates pressure transmission in dogs [J].
Dobson, G. ;
Flewitt, J. ;
Tyberg, J. V. ;
Moore, R. ;
Karamanoglu, M. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2006, 32 (02) :129-135
[9]   Neuroform stent assisted aneurysm treatment: evolving treatment strategies, complications and results of long term follow-up [J].
Fiorella, D. ;
Albuquerque, F. C. ;
Woo, H. ;
Rasmussen, P. A. ;
Masaryk, T. J. ;
McDougall, C. G. .
JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (01) :16-22
[10]   Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device [J].
Fiorella, David ;
Woo, Henry H. ;
Albuquerque, Felipe C. ;
Nelson, Peter K. .
NEUROSURGERY, 2008, 62 (05) :1115-1120