Thermal Comfort Aspects of Solar Gains during the Heating Season

被引:11
作者
Kalmar, Ferenc [1 ]
Kalmar, Tunde [1 ]
机构
[1] Univ Debrecen, Dept Bldg Serv & Bldg Engn, H-4028 Debrecen, Hungary
关键词
glazing; solar gains; thermal comfort; personalized ventilation; energy savings; ELECTROCHROMIC WINDOWS; ENERGY-CONSUMPTION; BUILDINGS; DESIGN; IMPACT; OPTIMIZATION; PERFORMANCE; WBGT; SAVINGS; RATIO;
D O I
10.3390/en13071702
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Glazing plays a key role in the energy balance of buildings. The aim of this paper is to enlighten the thermal discomfort caused by large glazed areas in the heating season and to point out a possible solution that can provide proper thermal comfort with low energy use. It is unusual to discuss the negative effects of solar gains on thermal comfort during the heating season. However, there are cases when glazing may lead to unforeseen indoor thermal discomfort conditions. Laboratory and on site measurements were performed in order to assess thermal discomfort caused by direct and diffuse radiation. It was shown that the WBGT (Wet Bulb Globe Temperature) index may exceed even 30 degrees C in the winter season in a room having large glazed area oriented to east. Laboratory tests performed in climate chamber have shown that the high PMV values cannot be reduced below 1.0, increasing the air change rate in the room. Using opaque drapes, the WBGT index was reduced by 2 degrees C, but the daylighting decreased substantially. It was demonstrated that by using advanced personalized ventilation systems, the appropriate thermal comfort can be provided avoiding the reduction of daylighting.
引用
收藏
页数:15
相关论文
共 42 条
  • [1] Shading and day-lighting controls energy savings in offices with fully-Glazed facades in hot climates
    Al Touma, Albert
    Ouahrani, Djamel
    [J]. ENERGY AND BUILDINGS, 2017, 151 : 263 - 274
  • [2] Energy consumption in buildings: A correlation for the influence of window to wall ratio and window orientation in Tripoli, Libya
    Alghoul, Samah K.
    Rijabo, Hassan G.
    Mashena, Mohamed E.
    [J]. JOURNAL OF BUILDING ENGINEERING, 2017, 11 : 82 - 86
  • [3] Occupancy-based zone-level VAV system control implications on thermal comfort, ventilation, indoor air quality and building energy efficiency
    Anand, Prashant
    Sekhar, Chandra
    Cheong, David
    Santamouris, Mattheos
    Kondepudi, Sekhar
    [J]. ENERGY AND BUILDINGS, 2019, 204
  • [4] Energy saving estimation for plug and lighting load using occupancy analysis
    Anand, Prashant
    Cheong, David
    Sekhar, Chandra
    Santamouris, Mattheos
    Kondepudi, Sekhar
    [J]. RENEWABLE ENERGY, 2019, 143 : 1143 - 1161
  • [5] A simplified tool for building layout design based on thermal comfort simulations
    Anand, Prashant
    Deb, Chirag
    Alur, Ramachandraiah
    [J]. FRONTIERS OF ARCHITECTURAL RESEARCH, 2017, 6 (02) : 218 - 230
  • [6] [Anonymous], 2014, ANN OCCUP HYG, DOI DOI 10.1093/ANNHYG/MEU050
  • [7] [Anonymous], 2007, 152512007 EN CEN
  • [8] Conjugate heat transfer analysis of double pane windows
    Aydin, O
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (02) : 109 - 116
  • [9] Wet-bulb globe temperature (WBGT) - its history and its limitations
    Budd, Grahame M.
    [J]. JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2008, 11 (01) : 20 - 32
  • [10] Direct and indirect measurement of WBGT index in transversal flow
    Buonanno, G
    Frattolillo, A
    Vanoli, L
    [J]. MEASUREMENT, 2001, 29 (02) : 127 - 135