Visualizing the dynamics of cerebral aneurysms with four-dimensional computed tomographic angiography

被引:59
作者
Ishida, F
Ogawa, H
Simizu, T
Kojima, T
Taki, W
机构
[1] Gen Med Ctr, Dept Neurosurg, Yokaichi, Mie, Japan
[2] Mie Univ, Sch Med, Dept Neurosurg, Tsu, Mie, Japan
关键词
aneurysms; four-dimensional angiography; hemodynamics;
D O I
10.1227/01.NEU.0000170540.17300.DD
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: This study was designed to assess cerebral aneurysm hemodynamics with four-dimensional (4-D) computed tomographic (CT) angiography. METHODS: Multislice computed tomography with a retrospective electrocardiography-gated reconstruction algorithm was used. The motions of the aneurysmal wall, bleb, and dissecting cavity were rendered observable in a 4-D CT movie. RESULTS: The findings for 30 patients with 34 aneurysms who underwent 4-D CT angiography were analyzed. Twenty-three aneurysms were documented in the anterior circulation region, and the remaining 11 aneurysms were in the posterior circulation. The average aneurysm size was 6.4 mm, and there were five large aneurysms. There were 28 saccular, 4 dissecting, and 2 fusiform aneurysms. 4-D CT movies were obtained successfully in all aneurysms. The aneurysm wall motion of two growing aneurysms exhibited a highly irregular pulsation in the 4-D CT movie. Pulsating blebs were detected in nine (32.1%) of the saccular aneurysms. In two patients with subarachnoid hemorrhage, preoperative 4-D CT angiography revealed dangerous pulsating blebs that were confirmed as the ruptured points during the surgical procedure. Specifically, in the dissecting aneurysms, the 4-D CT movie revealed a pulsating line, which provided accurate and detailed information regarding the dissecting cavity and intimal flap. The dissecting cavity revealed by the 4-D CT movie could not be detected with conventional or three-dimensional digital subtraction angiography. The 4-D CT movie images were highly useful in making anatomic judgments for the endovascular surgery procedure. CONCLUSION: 4-D CT images are valuable in determining aneurysmal wall dynamics. Highly useful information was obtained regarding intracranial aneurysms with 4-D CT angiography compared with other modalities. Further studies will be necessary to elucidate the optimal application of this new technology to both the pathological characteristics and therapeutic amelioration of aneurysmal features such as dome pulsation, blebs, and growing aneurysms.
引用
收藏
页码:460 / 470
页数:11
相关论文
共 32 条
  • [1] Effects of three-dimensional angiography on the coiling of cerebral aneurysms
    Albuquerque, FC
    Spetzler, RF
    Zabramski, JM
    McDougall, CG
    [J]. NEUROSURGERY, 2002, 51 (03) : 597 - 605
  • [2] Intracranial aneurysms: Clinical value of 3D digital subtraction angiography in the therapeutic decision and endovascular treatment
    Anxionnat, R
    Bracard, S
    Ducrocq, X
    Trousset, Y
    Launay, L
    Kerrien, E
    Braun, M
    Vaillant, R
    Scomazzoni, F
    Lebedinsky, A
    Picard, L
    [J]. RADIOLOGY, 2001, 218 (03) : 799 - 808
  • [3] Intracranial aneurysms: Detection and characterization with MR angiography with use of an advanced postprocessing technique in a blinded-reader study
    Atlas, SW
    Sheppard, L
    Goldberg, HI
    Hurst, RW
    Listerud, J
    Flamm, E
    [J]. RADIOLOGY, 1997, 203 (03) : 807 - 814
  • [4] Chen CJ, 2004, AM J NEURORADIOL, V25, P769
  • [5] De novo formation and rupture of an azygos pericallosal artery aneurysm - Case report
    Dietrich, W
    Reinprecht, A
    Gruber, A
    Czech, T
    [J]. JOURNAL OF NEUROSURGERY, 2000, 93 (06) : 1062 - 1064
  • [6] CLINICOSTATISTICAL STUDY ON MORPHOLOGICAL RISK-FACTORS OF MIDDLE CEREBRAL-ARTERY ANEURYSMS
    EBINA, K
    SHIMIZU, T
    SOHMA, M
    IWABUCHI, T
    [J]. ACTA NEUROCHIRURGICA, 1990, 106 (3-4) : 153 - 159
  • [7] Gaylord Gregg M, 2002, Radiol Manage, V24, P16
  • [8] NATURAL-HISTORY OF UNRUPTURED INTRACRANIAL ANEURYSMS - A LONG-TERM FOLLOW-UP-STUDY
    JUVELA, S
    PORRAS, M
    HEISKANEN, O
    [J]. JOURNAL OF NEUROSURGERY, 1993, 79 (02) : 174 - 182
  • [9] ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart
    Kachelriess, M
    Ulzheimer, S
    Kalender, WA
    [J]. MEDICAL PHYSICS, 2000, 27 (08) : 1881 - 1902
  • [10] The usefulness of 3D-CT angiography for the diagnosis of spontaneous vertebral artery dissection - report of two cases
    Kurokawa, Y
    Yonemasu, Y
    Kano, H
    Sasaki, T
    Inaba, K
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2000, 24 (02) : 115 - 119