Distribution of Escherichia coli O157:H7 in beef processed in a table-top bowl cutter

被引:12
作者
Flores, RA [1 ]
机构
[1] USDA ARS, Microbial Food Safety Res Unit, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
关键词
D O I
10.4315/0362-028X-67.2.246
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Beef-processing equipment can be contaminated with pathogens Such as Escherichia coli O157:H7 and Salmonella spp. The bowl cutter has wide application in particle-size reduction and blending of meat products. This study was undertaken to determine (i) the distribution patterns of E. coli O157:H7 in equipment components and ground beef produced with a table-top bowl cutter under different operational conditions and (ii) the likelihood that pathogen contamination can be transferred to subsequent batches after a batch of beef contaminated with E. coli O157:H7 has been processed in the same bowl cutter. A beef trim (44.6 +/- 29.5 g) inoculated with 2 log CFU of an E. coli O157:H7 mutant strain resistant to rifampicin (E. coli O157:H7(rif)) was fed by hand into an uncontaminated beef-trim batch under two different batch sizes (2 and 4 kg), three processing times (60, 120, and 240 s), and two feeding modes (running and stoppage fed). There were no significant differences (P greater than or equal to 0.05) among all the treatments for the averages of the counts of E. coli O157:H7(rif) distributed in the ground beef. Regardless of the processing time and the method used to feed the beef trims into the bowl cutter, the whole batch and the following subsequent batch became contaminated when previously contaminated beef was processed. Areas of the bowl cutter most likely to be contaminated with E. coli O157:H7 were (i) the material left on the top of the comb/knife guard and (ii) the knife. Material that overflowed the bowl cutter, when processing the batch with E. coli O157:H7rif, contaminated the equipment surroundings. A Pearson V probability distribution function was determined to describe the distribution of pathogenic organisms in the ground beef, a distribution that can also be applied when conducting process risk analyses on mixing-particle reduction operations for beef trims.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 13 条
[1]   Meat grinders and molecular epidemiology: Two supermarket outbreaks of Escherichia coli O157:H7 infection [J].
Banatvala, N ;
Magnano, AR ;
Cartter, ML ;
Barrett, TJ ;
Bibb, WF ;
Vasile, LL ;
Mshar, P ;
LambertFair, MA ;
Green, JH ;
Bean, NH ;
Tauxe, RV .
JOURNAL OF INFECTIOUS DISEASES, 1996, 173 (02) :480-483
[2]   Effects of chopping time, meat source and storage temperature on the colour of New Zealand type fresh beef sausages [J].
Boles, JA ;
Mikkelsen, VL ;
Swan, JE .
MEAT SCIENCE, 1998, 49 (01) :79-88
[3]  
BRAUER H, 1994, FLEISCHWIRTSCHAFT, V74, P677
[4]  
BRAUER HW, 1994, FLEISCHWIRTSCHAFT, V74, P737
[5]   Attachment of Escherichia coli O157:H7 in ground beef to meat grinders and survival after sanitation with chlorine and peroxyacetic acid [J].
Farrell, BL ;
Ronner, AB ;
Wong, ACL .
JOURNAL OF FOOD PROTECTION, 1998, 61 (07) :817-822
[6]   Distribution patterns of Escherichia coli O157:H7 in ground beef produced by a laboratory-scale grinder [J].
Flores, RA ;
Tamplin, ML .
JOURNAL OF FOOD PROTECTION, 2002, 65 (12) :1894-1902
[7]   Contamination of beef trimmings with Escherichia coli during a carcass breaking process [J].
Gill, CO ;
McGinnis, JC .
FOOD RESEARCH INTERNATIONAL, 2000, 33 (02) :125-130
[8]  
Haack E, 1999, FLEISCHWIRTSCHAFT, V79, P35
[9]  
JOHNSON NL, 1970, CONTINUOUS UNIVARIAT, V1, P9
[10]   Dry mixing of wheat flours: Effect of particle properties and blending ratio [J].
Kuakpetoon, D ;
Flores, RA ;
Milliken, GA .
LEBENSMITTEL-WISSENSCHAFT UND-TECHNOLOGIE-FOOD SCIENCE AND TECHNOLOGY, 2001, 34 (03) :183-193